Form 3 — 건축물의 구조기준 등에 관한 규칙
267091 · 2024-12-17
■ Rules on Structural Standards for Buildings, etc. [Attachment Form No. 3] <Amended Feb. 12, 2020> (Chapter 1)
Certificate of Structural Safety and Seismic Design (Small-scale Buildings - Concrete Structures)
┌────────┬─────────────────────────────────────────┐
│1) Project Name │ │
├────────┼─────────────────────────────────────────┤
│2) Site Location │ │
├────────┼───────┬─────────┬────┬──────────────────┤
│3) Scale │2nd Floor Above Ground Floor Height │m │Number of floors │Basement() Floor/Ground() Floor │
│ ├───────┼─────────┼────┼──────────────────┤
│ │Ground Floor 1st Floor Ceiling Height │m │Gross Floor Area │m2 │
│ ├───────┼─────────┤ │ │
│ │Basement Floor Height │m │ │ │
├────────┼───────┴─────────┴────┼──────────────────┤
│4) Purpose │Residential Facilities( ) / Neighborhood Living Facilities( ) │* 「Small-scale building structures │
├────────┼──────────────────────┤기준」 │
│5) Structure Format │Laterally restrained frame( ) / Non-laterally restrained frame( ) │ │
├────────┼───────┬─────────┬────┤ │
│6) Application Restriction │Design Load │Presence or absence of floor dead load exceeded│With / Without │ │
│ │ ├─────────┼────┤ │
│ │ │Presence or absence of floor live load exceedance│With / Without │ │
│ │ ├─────────┼────┤ │
│ │ │Applicable to areas exceeding snow load│With / Without │ │
│ │ ├─────────┼────┤ │
│ │ │Applicable to areas exceeding wind load│With / Without │ │
│ ├───────┼─────────┼────┤ │
│ │StructuralPlan │Vertical member discontinuity │With / Without │ │
│ │ ├─────────┼────┤ │
│ │ │1,2F Structural Type Identity│With / Without │ │
│ │ ├─────────┼────┤ │
│ │ │CantileverBoard │With / Without │ │
│ │ │ ├────┼──────────────────┤
│ │ │ │Length m │*Maximum 1.5m or less │
├────────┼───────┼─────────┴────┼──────────────────┤
│7) Floor Plan │Flat Size │Width: m │*Aspect Ratio │
│ │ │VerticalLength: m │1:5 Below │
│ ├───────┼──────────────┴──────────────────┤
│ │ColumnSpan │MAX m, Minimum m │
│ ├───────┼─────────────────────────────────┤
│ │Beam Placement Spacing │MAX m, Minimum m │
├────────┼───────┼─────────┬────┬──────────────────┤
│8) Material Strength │Concrete │fck= MPa │Reinforcement │fy= MPa │
├────────┼───────┼─────────┼────┼──────────────────┤
│9) Slab │Short-side direction │m │Thickness │mm │
│ │Maximum Span │ │ │ │
├────────┼───────┼─────────┼────┴──────────────────┤
│10) Bo │Section │Maximum span(m) │Sectional Size(mm) │
│ │ │ ├────┬──────────────────┤
│ │ │ │Width │Depth │
│ ├───────┼─────────┼────┼──────────────────┤
│ │SmallBo │ │ │ │
│ ├───────┼─────────┼────┼──────────────────┤
│ │bigbo │ │ │ │
│ ├───────┼─────────┼────┼──────────────────┤
│ │small beam │ │ │ │
│ │supporting large beam │ │ │ │
├────────┼───────┴─────────┼────┴──────────────────┤
│11) Pillar │Maximum Cumulative Load Area(m2) │Sectional Size(mm) │
│ │ ├────┬──────────────────┤
│ │ │Width │Depth │
│ ├───────┬─────────┼────┼──────────────────┤
│ │2nd Floor Pillar │ │ │ │
│ ├───────┼─────────┼────┼──────────────────┤
│ │1st Floor Pillar │ │ │ │
│ ├───────┼─────────┼────┼──────────────────┤
│ │Basement Column │ │ │ │
├────────┼───────┴─────────┼────┴──────────────────┤
│12) Basic │Landfill Area/Applicability to Soft Soil Ground│ With / Without │
│ ├─────────────────┼───────────────────────┤
│ │Foundation Type/Thickness │Column Bottom: / │
│ │ │LowerWall: / │
├────────┼───────┬─────────┴────┬──────────────────┤
│13) Shear Wall │Placement Direction │Total wall length(m) │Wall Thickness(mm) │
│ │ ├──────┬───────┤ │
│ │ │1st floor │2nd floor │ │
│ ├───────┼──────┼───────┼──────────────────┤
│ │Horizontal Direction │ │ │ │
│ ├───────┼──────┼───────┼──────────────────┤
│ │Vertical Direction │ │ │ │
├────────┼───────┼──────┴───────┼──────────────────┤
│14) Non-structural elements │Architectural Non-structural Elements│ │Confirmation during the construction phase │
│ ├───────┼──────────────┤Specify necessary non-structural elements │
│ │Mechanical·Electrical │ │ │
│ │Non-structural elements │ │ │
├────────┼───────┴──────────────┴──────────────────┤
│15) Special Notes │ │
├────────┴─────────────────────────────────────────┤
│In accordance with Article 48 of the Building Act and Article 32 of the Enforcement Decree of the same Act, I hereby submit the Certificate of Verification of Structural Safety and Seismic Design of a Building.│
│ │
│ Year month day │
│ │
│Author (Designer): (Seal) │
│ │
│Address: / Contact: │
└──────────────────────────────────────────────────┘
210㎜×297㎜[White Paper (80g/㎡)]
■ Rules on Structural Standards for Buildings, etc. [Attachment Form No. 3] (Chapter 2)
Certificate of Structural Safety and Seismic Design (Small-scale Buildings - Concrete Wall Structure)
┌───────┬──────────────────────────────────────────┐
│1) Project Name │ │
├───────┼──────────────────────────────────────────┤
│2) Site Location │ │
├───────┼─────────┬───────┬────┬───────────────────┤
│3) Scale │2nd Floor Above Ground Floor Height │m │Number of floors │Basement( )Floor/Ground( )Floor │
│ ├─────────┼───────┼────┼───────────────────┤
│ │Ground Floor 1st Floor Ceiling Height │m │Gross Floor Area │m2 │
│ ├─────────┼───────┤ │ │
│ │Basement Floor Height │m │ │ │
├───────┼─────────┴───────┴────┼───────────────────┤
│4) Purpose │Residential Facilities( ) / Neighborhood Living Facilities( ) │*「Small-scale building structures │
├───────┼─────────┬───────┬────┤기준」Refer to │
│5) Application Restriction │Design Load │Presence or absence of floor dead load exceeded│With / Without │ │
│ │ ├───────┼────┤ │
│ │ │Presence or absence of floor live load exceedance│With / Without │ │
│ │ ├───────┼────┤ │
│ │ │Applicable to areas exceeding snow load│With / Without │ │
│ │ ├───────┼────┤ │
│ │ │Applicable to areas exceeding wind load│With / Without │ │
│ ├─────────┼───────┼────┤ │
│ │StructuralPlan │Vertical member discontinuity│With / Without │ │
│ │ ├───────┼────┤ │
│ │ │1,2F Structural Type Identity│With / Without │ │
│ │ ├───────┼────┤ │
│ │ │CantileverBoard │With / Without │ │
│ │ │ ├────┼───────────────────┤
│ │ │ │Length m │*Maximum 1.5m or less │
├───────┼─────────┼───────┴────┼───────────────────┤
│6) Floor Plan │Flat Size │Width: m │*Aspect ratio 1:5 │
│ │ │VerticalLength: m │Below │
│ ├─────────┼────────────┴───────────────────┤
│ │To concrete wall │MAX m │
│ │Enclosed floor area │ │
│ ├─────────┼────────────────────────────────┤
│ │Slab Short Side Direction │MAX m │
│ │Span │ │
├───────┼─────────┼───────┬────┬───────────────────┤
│7) Material Strength │Concrete │fck= MPa │Reinforcement │fy= MPa │
├───────┼─────────┼───────┼────┼───────────────────┤
│8) Slab │Short-sided direction │m │Thickness │mm │
│ │Maximum Span │ │ │ │
├───────┼─────────┼───────┴────┴───────────────────┤
│9) BO │Section │Sectional Size(mm) │
│ │ ├───────┬────────────────────────┤
│ │ │Width │Depth │
│ ├─────────┼───────┼────────────────────────┤
│ │InteriorWall │ │ │
│ │ │ │ │
│ ├─────────┼───────┼────────────────────────┤
│ │Exterior wall and │ │ │
│ │Stairwell Wall │ │ │
├───────┼─────────┴───────┼────────────────────────┤
│10) Wall │Wall Thickness(mm) │Byeolyul │
│ ├─────────┬───────┼────┬───────────────────┤
│ │InteriorWall │ │ 2nd floor: │* See A.0206.2(3) │
│ ├─────────┼───────┼────┤ │
│ │Exterior wall and │ │ 1st floor: │ │
│ │Stairwell Wall │ │ │ │
├───────┼─────────┴───────┼────┴───────────────────┤
│11) Basic │Landfill Area/Applicability to Soft Soil Ground│ With / Without │
│ ├─────────┬───────┴────────────────────────┤
│ │Strip Foundation Width/Thickness │MinimumWidth mm, Minimum Thickness mm │
│ │ ├────────────────────────────────┤
│ │ │MAX Width mm, Maximum Thickness mm │
├───────┼─────────┼────────────┬───────────────────┤
│12) Non-structural elements│Architectural Non-structural Elements │ │Confirmation during the construction phase │
│ ├─────────┼────────────┤Specify necessary non-structural elements │
│ │Mechanical·Electrical │ │ │
│ │Non-structural elements │ │ │
├───────┼─────────┴────────────┴───────────────────┤
│13) Special Notes │ │
├───────┴──────────────────────────────────────────┤
│In accordance with Article 48 of the Building Act and Article 32 of the Enforcement Decree of the same Act, I hereby submit the Certificate of Verification of Structural Safety and Seismic Design of a Building.│
│ │
│ Year month day │
│ │
│Author (Designer): (Seal) │
│ │
│Address: / Contact: │
└──────────────────────────────────────────────────┘
210㎜×297㎜[White Paper (80g/㎡)]
■ Rules on Structural Standards for Buildings, etc. [Attachment Form No. 3] (Chapter 3)
Certificate of Structural Safety and Seismic Design (Small-scale Buildings - Steel Structure)
┌─────────┬──────────────────────────────────────────┐
│1) Project Name │ │
├─────────┼──────────────────────────────────────────┤
│2) Site Location │ │
├─────────┼────────┬───────────────┬─────┬───────────┤
│3) Scale │2nd Floor Above Ground Floor Height │m │Number of floors │Basement() Floor/Ground() Floor │
│ ├────────┼───────────────┼─────┼───────────┤
│ │Ground Floor 1st Floor Ceiling Height │m │Gross Floor Area │m2 │
│ ├────────┼───────────────┤ │ │
│ │Basement Floor Height │m │ │ │
├─────────┼────────┴───────────────┴─────┼───────────┤
│4) Purpose │Residential Facilities( ) / Neighborhood Living Facilities( ) │* 「Small-scale building structures │
├─────────┼──────────────────────────────┤기준」 │
│5) Structure Format │Laterally restrained frame( ) / Non-laterally restrained frame( ) │ │
├─────────┼────────┬───────────────┬─────┤ │
│6) Application Restriction │Design Load │Presence or absence of floor dead load exceeded │With / Without │ │
│ │ ├───────────────┼─────┤ │
│ │ │Presence or absence of floor live load exceedance │With / Without │ │
│ │ ├───────────────┼─────┤ │
│ │ │Applicable to areas exceeding snow load │With / Without │ │
│ │ ├───────────────┼─────┤ │
│ │ │Applicable to areas exceeding wind load │With / Without │ │
│ ├────────┼───────────────┼─────┤ │
│ │StructuralPlan │Vertical member discontinuity │With / Without │ │
│ │ ├───────────────┼─────┤ │
│ │ │1,2F Structural Type Identity │With / Without │ │
│ │ ├───────────────┼─────┤ │
│ │ │CantileverBoard │With / Without │ │
│ │ │ ├─────┼───────────┤
│ │ │ │Length m │*Maximum 1.5m or less │
├─────────┼────────┼───────────────┴─────┼───────────┤
│7) Floor Plan │Flat Size │Width: m │*Aspect Ratio │
│ │ │VerticalLength: m │1:5 Below │
│ ├────────┼──────┬──────────────┴───────────┤
│ │ColumnSpan │MAX m,│*Maximum span 10m or less │
│ │ │ │*When exceeding 8m 0604Lateral Restraint Frame Design │
│ │ │ │must be applied │
│ ├────────┼──────┼──────────────────────────┤
│ │Beam Placement Spacing │MAX m,│*Maximum 3.5m or less │
├─────────┼────────┼──────┴──────────────────────────┤
│8) Roof Structure │Structure Format │Lightweight Finished Roof / Reinforced Concrete Roof │
│ ├────────┼─────────────────────────────────┤
│ │Roof type │Sloped Roof / Flat Roof │
├─────────┼────────┼───────────────┬─────┬───────────┤
│9) Material Strength │Concrete │fck= MPa │Reinforcement │fy= MPa │
│ ├────────┼───────────────┼─────┴───────────┤
│ │Steel │Specification: │Fy= MPa │
├─────────┼────────┴─────┬─────────┼─────┬───────────┤
│10) Ground Floor Slab │Short side direction maximum span │ m │Thickness │ mm │
├─────────┼──────────────┼─────────┼─────┴───────────┤
│11) Bo │Category │Maximum span(m) │H Sectional Dimensions (mm) │
│ ├──────────────┼─────────┼─────────────────┤
│ │smallbo │ │ │
│ ├──────────────┼─────────┼─────────────────┤
│ │bigbo │ │ │
│ ├──────────────┼─────────┼─────────────────┤
│ │Large beam supporting a small beam │ │ │
├─────────┼──────────────┴─────────┼─────────────────┤
│12) Pillar │Load area (m2) │Maximum cross-sectional size (mm) │
│ ├──────────────┬─────────┼─────────────────┤
│ │2nd Floor Pillar │ │ │
│ ├──────────────┼─────────┼─────────────────┤
│ │1st Floor Pillar │ │ │
│ ├──────────────┼─────────┼─────────────────┤
│ │Basement reinforced concrete column │ │ │
├─────────┼──────────────┴─────────┼─────────────────┤
│13) Basic │Landfill Area/Applicability to Soft Soil Ground │ With / Without │
│ ├──────────────┬─────────┴─────────────────┤
│ │Foundation Type/Thickness │Column Bottom: / │
│ │ │LowerWall: / │
├─────────┼───────┬──────┼─────────┬──────┬──────────┤
│14) Lateral Force Resistance Element │ Shear Wall │With / Without │Placement Direction │Horizontal │VerticalOrientation │
│ │ │ ├─────────┼──────┼──────────┤
│ │ │ │Number of items per floor/Total length │ / m│ / m │
│ │ │ ├─────────┼──────┼──────────┤
│ │ │ │WallThickness │ mm │ mm │
│ ├───────┼──────┼─────────┼──────┼──────────┤
│ │ Vertical Bracing │With / Without │Number of items per floor │open │open │
│ │ │ ├─────────┼──────┼──────────┤
│ │ │ │Braise Angle │도 │To │
│ ├───────┴──────┴─────────┴──────┴──────────┤
│ │ * For installation standards of vertical bracing or shear walls, refer to 0604.5 │
│ │ * If not installed, 0605 Design of non-laterally restrained frames must be applied │
├─────────┼───────┬─────────────────────────┬────────┤
│15) Non-structural elements │Architectural Non-structural Elements│ │In the construction phase │
│ ├───────┼─────────────────────────┤requiring verification │
│ │Mechanical·Electrical │ │Non-structural elements description │
│ │Non-structural element │ │ │
├─────────┼───────┴─────────────────────────┴────────┤
│16) Special Notes │ │
├─────────┴──────────────────────────────────────────┤
│In accordance with Article 48 and Article 32 of the Building Act, I hereby submit the Certificate of Verification of Structural Safety and Seismic Design of a Building. │
│ │
│ Year month day │
│ │
│Author (Designer): (Seal) │
│ │
│Address: / Contact: │
└────────────────────────────────────────────────────┘
210㎜×297㎜[White Paper (80g/㎡)]
■ Rules on Structural Standards for Buildings, etc. [Attachment Form No. 3] (Chapter 4)
Certificate of Structural Safety and Seismic Design (Small-scale Buildings - Masonry Structure)
┌────────┬──────────────────────────────────────┐
│1) Project Name │ │
├────────┼──────────────────────────────────────┤
│2) Site Location │ │
├────────┼─────────┬────────┬──────┬────────────┤
│3) Scale │2nd Floor Above Ground Floor Height │m │Number of floors │Basement( )Floor/Ground( )Floor │
│ ├─────────┼────────┼──────┼────────────┤
│ │Ground Floor 1st Floor Ceiling Height │m │Gross Floor Area │m2 │
│ ├─────────┼────────┤ │ │
│ │Basement Floor Height │m │ │ │
├────────┼─────────┴────────┴──────┼────────────┤
│4) Purpose │Residential Facilities( ) / Neighborhood Living Facilities( ) │*「Small-scale Building Structural Standards」 │
├────────┼─────────┬────────┬──────┤Reference │
│5) Application Restriction │Design Load │Floor dead load exceeded │Yes / No │ │
│ │ ├────────┼──────┤ │
│ │ │Floor Live Load Exceeded│With / Without │ │
│ │ ├────────┼──────┤ │
│ │ │Applicable to areas exceeding snow load│With / Without │ │
│ │ ├────────┼──────┤ │
│ │ │Applicable to areas exceeding wind load│With / Without │ │
│ ├─────────┼────────┼──────┤ │
│ │StructuralPlan │Discontinuity of upper and lower load-bearing walls│With / Without │ │
│ │ ├────────┼──────┤ │
│ │ │1,2F Structural Type Identity│With / Without │ │
│ │ ├────────┼──────┤ │
│ │ │CantileverBoard │With / Without │ │
│ │ │ ├──────┼────────────┤
│ │ │ │Length m │*Maximum 1.5 m or less │
├────────┼─────────┼────────┴──────┴────────────┤
│6) Floor Plan │Flat Size │Width : m │
│ │ │VerticalLength : m │
│ ├─────────┼────────────────────────────┤
│ │as load-bearing wall │MAX m2 │
│ │Enclosed floor area │ │
│ ├─────────┼────────────────────────────┤
│ │Load-bearing wall lateral support length│MAX m │
├────────┼─────────┼────────┬───────────────────┤
│7) Material Strength │MasonryMaterials │Brick( ) / ALC Block( )│fm(fALC)= MPa │
│ ├─────────┼────────┼──────┬────────────┤
│ │Concrete │fck = MPa│Mortar │fg = MPa │
├────────┼─────────┼──────┬─┼──────┼────────────┤
│8) Slab │Brick Structure │Short-sided direction │m │Thickness │ mm │
│ │ │Maximum Span │ │ │ │
│ ├─────────┼──────┼─┼──────┼────────────┤
│ │ALC Structure (Panel) │MAXLength │m │Panel Thickness │ mm │
├────────┼─────────┼──────┴─┼──────┼────────────┤
│9) Inbangbo │Sectional Size │ mm │Opening Width │m │
├────────┼─────────┼────────┼──────┼────────────┤
│10) Border beam │Sectional Size │ mm │Arrangement │m │
├────────┼─────────┴────────┼──────┴────────────┤
│11) Basic │Landfill area, soft soil ground applicable │With / Without │
│ ├─────────┬────────┼───────────────────┤
│ │StripFoundation( ) │Foundation Wall : mm │Thickness : mm │
│ ├─────────┼────────┼───────────────────┤
│ │OntongGicho( ) │ProtrusionLength** mm │Thickness : mm │
│ │ ├────────┤ │
│ │ │**If there is a protrusion length│ │
├────────┼─────────┴────────┴──────┬────────────┤
│12) Byeoryul │2nd floor: │*「Small-scale Building Structural Standards」 │
│ ├─────────────────────────┤Reference │
│ │1st floor: │ │
├────────┼───────┬─────────────────┼────────────┤
│13) Non-structural elements │Non-structural elements of architecture│ │Confirmation during the construction phase │
│ ├───────┼─────────────────┤Specify necessary non-structural elements │
│ │Mechanical·Electrical │ │ │
│ │Non-structural elements │ │ │
├────────┼───────┴─────────────────┴────────────┤
│14) Special Notes │ │
├────────┴──────────────────────────────────────┤
│ In accordance with Article 48 of the Building Act and Article 32 of the Enforcement Decree of the same Act, I hereby submit the Certificate of Structural Safety and Seismic Design. │
│ │
│ Year month day │
│ │
│Author (Designer): (Seal) │
│ │
│Address: / Contact: │
└───────────────────────────────────────────────┘
210 mm
■ Rules on Structural Standards for Buildings, etc. [Attachment Form No. 3] (Chapter 5)
Certificate of Structural Safety and Seismic Design (Small-scale Buildings - Timber Structure)
┌─────────┬─────────────────────────────────────────────┐
│ 1) Project Name │ │
├─────────┼─────────────────────────────────────────────┤
│ 2) Site Location │ │
├─────────┼───────┬─────────────┬───────┬───────────────┤
│ 3) Scale │2nd Floor Above Ground Floor Height │m │Number of floors │1st Basement Floor / 2nd Floor Above Ground │
│ ├───────┼─────────────┼───────┼───────────────┤
│ │Ground Floor 1st Floor Height │m │Gross Floor Area │m2 │
│ ├───────┼─────────────┤ │ │
│ │Basement Floor Height │m │ │ │
├─────────┼───────┴─────────────┴───────┼───────────────┤
│ 4) Purpose │Residential Facilities ( ) / Neighborhood Living Facility ( ) │*「Small Scale │
├─────────┼─────────────────────────────┤Refer to "Architectural Structural Standards" │
│ 5) Structure Format │Light Timber Structure ( ) / Heavy Timber Structure ( ) │ │
├─────────┼───────┬─────────────┬───────┤ │
│ 6) Application Restriction │Design Load │Presence or absence of floor dead load exceeded │With / Without │ │
│ │ ├─────────────┼───────┤ │
│ │ │Presence or absence of floor live load exceedance │With / Without │ │
│ │ ├─────────────┼───────┤ │
│ │ │Applicable to areas exceeding snow load │With / Without │ │
│ │ ├─────────────┼───────┤ │
│ │ │Applicable to areas exceeding wind load │With / Without │ │
│ ├───────┼─────────────┼───────┤ │
│ │StructuralPlan │Vertical member discontinuity │With / Without │ │
│ │ ├─────────────┼───────┤ │
│ │ │1,2F Structural Type Identity │With / Without │ │
│ │ ├─────────────┼───────┤ │
│ │ │CantileverBoard │With / Without │ │
│ │ │ ├───┬───┼───────────────┤
│ │ │ │Length │m │* Max 1.5m or less │
├─────────┼───────┼───────────┬─┴───┴───┼───────────────┤
│ 7) Floor Plan │Flat Size │Circumscribed rectangle long side length :│m │* Longest side 18m or less │
│ │ │Circumscribed rectangle short side length :│m │* Long side:short side length ratio │
│ │ │ │ │3:1 Below │
│ ├───────┼───────┬───┴─┬───────┼───────────────┤
│ │Vertical Load Support │MAX │m │ │* 6m or less │
│ │Structure Spacing │ │ │ │ │
│ ├───────┼───────┼─────┼───────┼───────────────┤
│ │Between load-bearing walls │MAX │m │ │* 12m or less │
│ │Distance │ │ │ │ │
├─────────┼───────┼────┬──┴─────┼───────┼──────┬────────┤
│ 8) Structural Timber │Type │ │tree species │ │Grade │ │
├─────┬───┼───────┼────┼────────┼───────┼──────┼────────┤
│ 9) Roof │Rafter│Span │m │Sectional Dimensions │ │Apply │ │
│ │ │ │ │(mmxmm) │ │Span Table │ │
│ ├───┼───────┼────┼────────┼───────┼──────┼────────┤
│ │Cover │Type │ │Thickness │mm │Nailing │mm │
│ │ │ │ │ │ │Interval │ │
├─────┼───┼───────┼────┼────────┼───────┼──────┼────────┤
│ 10) Ceiling │Joist │Span │m │Sectional Dimensions │ │Apply │ │
│ │ │ │ │(mmxmm) │ │Span Table │ │
│ ├───┼───────┼────┼────────┼───────┼──────┼────────┤
│ │Cover │Type │ │Thickness │mm │Nailing │mm │
│ │ │ │ │ │ │Interval │ │
├─────┼───┼───────┼────┼────────┼───────┼──────┼────────┤
│ 11) Bottom │Joist │Span │m │Sectional Dimensions │ │Apply │ │
│ │ │ │ │(mmxmm) │ │Span Table │ │
│ ├───┼───────┼────┼────────┼───────┼──────┼────────┤
│ │Cover │Type │ │Thickness │mm │Nailing │mm │
│ │ │ │ │ │ │Interval │ │
├─────┴───┼───────┴────┴────────┼───────┴──────┴────────┤
│ 12) Vertical Load │Light Timber Structure │Heavy Timber Structure │
│ResistorStructure │ ├──┬──┬─────┬────┬──────┤
│ │ │Location│Type│Sectional Dimensions │Interval │Application Span Table │
│ │ │ │ │(mmxmm) │(m) │ │
│ ├───┬────┬───┬────┬───┼──┼──┼─────┼────┼──────┤
│ │1st floor │Sectional Dimensions│ │Interval │mm │1st floor │Pillar│ │ │ │
│ │stud│(mmxmm) │ │ │ │ ├──┼─────┼────┼──────┤
│ │ │ │ │ │ │ │Bo │ │ │ │
│ ├───┼────┼───┼────┼───┼──┼──┼─────┼────┼──────┤
│ │2nd floor │Sectional Dimensions│ │Interval │mm │2nd floor │Pillar│ │ │ │
│ │stud│(mmxmm) │ │ │ │ ├──┼─────┼────┼──────┤
│ │ │ │ │ │ │ │Bo │ │ │ │
├─────────┼───┴┬───┴───┴─┬──┴───┴─┬┴──┴─────┴┬───┴──────┤
│ 13) Load-bearing wall or │Direction │(mm) │(mm) │Male(mm) │Book(mm) │
│Shear Wall │ ├────┬────┼───┬────┼────┬─────┼────┬─────┤
│ │ │Length │MinimumLength│Length │MinimumLength│Length │MinimumLength │Length │MinimumLength │
│ ├────┼────┼────┼───┼────┼────┼─────┼────┼─────┤
│ │1st floor │ │ │ │ │ │ │ │ │
│ │Load-bearing wall │ │ │ │ │ │ │ │ │
│ │인정 구간│ │ │ │ │ │ │ │ │
│ ├────┼────┼────┼───┼────┼────┼─────┼────┼─────┤
│ │2nd floor │ │ │ │ │ │ │ │ │
│ │Load-bearing wall │ │ │ │ │ │ │ │ │
│ │인정 구간간│ │ │ │ │ │ │ │ │
├─────────┼────┴────┴────┴───┴──┬─┴────┴─────┴────┴─────┤
│ 14) Basic │Landfill Area/Applicability to Soft Soil Ground │ With / Without │
│ ├──────┬────┬────┬────┴┬──┬────┬──────┬───────┤
│ │Light Timber Structure │StripFoundation( )│FoundationWall │mm │Basic│mm │Basic │mm │
│ │ │ │Thickness │ │Thickness│ │Width │ │
│ │ ├────┼────┴───┬─┴──┴┬───┴────┬─┴───────┤
│ │ │OntongGicho( )│Width of reinforcement section │mm │Reinforcement Section Depth │mm │
│ ├──────┼────┼────┬───┴─┬──┬┴───┬────┴─┬───────┤
│ │Heavy Timber Structure │Column Foundation│horo │mm │Vertical│mm │Depth │mm │
├─────────┼──────┼────┴────┴─────┴──┴────┴┬─────┴───────┤
│ 15) Non-structural elements │Architectural Non-structural Elements│ │Confirmation during the construction phase │
│ ├──────┼────────────────────────┤Specify necessary non-structural elements │
│ │Mechanical·Electrical │ │ │
│ │Non-structural element │ │ │
├─────────┼──────┴────────────────────────┴─────────────┤
│ 16) Special Notes │ │
├─────────┴─────────────────────────────────────────────┤
│In accordance with Article 48 of the Building Act and Article 32 of the Enforcement Decree of the same Act, I hereby submit the Certificate of Verification of Structural Safety and Seismic Design of a Building. │
│ │
│ Year month day │
│ │
│Author (Designer): (Signature or seal) │
│ │
│ Address: / Contact: │
└───────────────────────────────────────────────────────┘
210㎜×297㎜[White Paper (80g/㎡)]
■ Rules on Structural Standards for Buildings, etc. [Attachment Form No. 3] (Chapter 6)
Structural Safety and Seismic Design Verification Certificate (Small-scale Buildings - Traditional Timber Structure)
┌────────┬───────────────────────────────────────────┐
│1) Project Name │ │
├────────┼───────────────────────────────────────────┤
│2) Site Location │ │
├────────┼────────┬──────────┬────────────┬──────────┤
│3) Scale │Total Height │ m │Number of floors │Underground Floor/Ground floor │
│ ├────────┼──────────┼────────────┼──────────┤
│ │2nd Floor Above Ground Floor Height │ m │Gross Floor Area │ m2 │
│ ├────────┼──────────┤ │ │
│ │Ground Floor 1st Floor Ceiling Height │ m │ │ │
│ ├────────┼──────────┤ │ │
│ │Basement Floor Height │ m │ │ │
├────────┼────────┴──────────┴────────────┼──────────┤
│4) Purpose │Residential Facilities ( ) / Neighborhood Living Facilities ( ) │*「Small-scale building structure │
├────────┼────────┬───────────────────────┤기준" │
│5) Structure Format │Furniture Type │3-car furniture type ( ) / 5-car furniture type ( ) │ │
│ ├────────┼───────────────────────┤ │
│ │Roof Load │normal 4kN/m2 ( ) / Weight 6kN/m2 ( ) │ │
├────────┼────────┼──────────┬────────────┤ │
│6) Application Restriction │Design Load │Presence or absence of floor dead load exceeded│With / Without │ │
│ │ ├──────────┼────────────┤ │
│ │ │Presence or absence of floor live load exceedance│With / Without │ │
│ │ ├──────────┼────────────┤ │
│ │ │Applicable to areas exceeding snow load│With / Without │ │
│ │ ├──────────┼────────────┤ │
│ │ │Applicable to areas exceeding wind load│With / Without │ │
│ ├────────┼──────────┼────────────┤ │
│ │StructuralPlan │Vertical member discontinuity │With / Without │ │
│ │ ├──────────┼────────────┤ │
│ │ │1,2F Structural Type Identity│With / Without │ │
│ │ ├──────────┼────────────┼──────────┤
│ │ │Eave Depth (Horizontal Projection Length)│ m │*Maximum 1.5m or less │
│ │ ├──────────┼────────────┼──────────┤
│ │ │Eave Depth (Horizontal Projection Length)│ m │*Maximum 2.5m or less │
├────────┼────────┼──────────┼──────┬─────┼─────┬────┤
│7) Floor Plan │Maximum Span │3-car household area ( ) │ViewingDirection │ m │Principal Direction │ m │
│ │ ├──────────┼──────┼─────┼─────┼────┤
│ │ │5-car household area ( ) │ViewingDirection │ m │Principal Direction │ m │
├────────┼────────┼─────┬────┴──────┼─────┼─────┴────┤
│8) Structural Timber │Timber ( ) │TreeSpecies(Group) │ │Grade │ │
│ ├────────┼─────┼───────────┼─────┼──────────┤
│ │Laminated Timber ( ) │Type │ │Grade │ │
├────────┼────────┼─────┼───────────┼─────┼──────────┤
│9) Structural Member │Horizontal Member │Bulk │ mmxmm │Jongbo │ mmxmm │
│(Representative Section │(Explosion x Dance) ├─────┼───────────┼─────┼──────────┤
│) │ │Jusimdori │ mmxmm │Jongdori │ mmxmm │
│ │ ├─────┼───────────┼─────┼──────────┤
│ │ │ugnyeo │ mmxmm │Rafter(Long-sided)│ mm │
│ ├────────┼─────┼───────────┼─────┼──────────┤
│ │Vertical Member │Column(Square)│ mmxmm │Column(Circular)│ mm │
│ │(Width or Diameter) │ │ │ │ │
├────────┼────────┼─────┴───────────┼─────┴──────────┤
│10) Lateral force │ Direction │X Directional Shear Wall (Based on 1st Floor) │Y Directional Shear Wall (Based on 1st Floor) │
│resistor element │ Type ├───────┬─────────┼───────┬────────┤
│ │ │RequiredLength │Design Length │RequiredLength │Design Length │
│ ├────────┼───────┼─────────┼───────┼────────┤
│ │Seismic Load │ m │ m │ m │ m │
│ ├────────┼───────┼─────────┼───────┼────────┤
│ │Wind Load │ m │ m │ m │ m │
│ ├────────┼───────┴─────────┴───────┴────────┤
│ │Remarks │Shear walls are calculated based on the 1st floor, and the 2nd floor is applied the same way as the 1st floor. │
├────────┼────────┴──────────┬───────────────────────┤
│11) Basic │Landfill Area/Applicability to Soft Soil Ground │With / Without │
│ ├────────┬─────┬────┴────────────┬─────┬────┤
│ │Foundation Type/Thickness │ ColumnLower │IndependentFoundation( ) / OntongGicho( )│MinimumThickness │ mm │
│ │ ├─────┼─────────────────┼─────┼────┤
│ │ │ LowerWall │StripFoundation ( ) / OntongGicho( )│MinimumThickness │ mm │
├────────┼───────┬┴─────┴─────────────┬───┴─────┴────┤
│12) Non-structural elements │Architectural Non-structural Elements│ │Confirmation during the construction phase │
│ ├───────┼────────────────────┤Specify necessary non-structural elements │
│ │Mechanical·Electrical │ │ │
│ │Non-structural elements │ │ │
├────────┼───────┴────────────────────┴──────────────┤
│13) Special Notes │ │
├────────┴───────────────────────────────────────────┤
│In accordance with Article 48 of the Building Act and Article 32 of the Enforcement Decree of the same Act, I hereby submit the Certificate of Verification of Structural Safety and Seismic Design of a Building. │
│ │
│ Year month day │
│ │
│Author (Designer): (Seal) │
│ │
│Address: / Contact : │
└────────────────────────────────────────────────────┘
210㎜×297㎜[White Paper (80g/㎡)]