Form 1 — 건축물의 구조기준 등에 관한 규칙

267091 · 2024-12-17

■ Rules on Structural Standards for Buildings, etc. [Attachment Form No. 1] <Amended Nov. 9, 2018> ┌───────────────────────────────────────────┐ │Certificate of Structural Safety and Seismic Design (Buildings of 6 Stories or More) │ ├─────────┬─────────────────────────┬───────┤ │1) Project Name │ │Remarks │ ├─────────┼─────────────────────────┼───────┤ │2) Site Location │ / Regional Coefficient │ │ ├─────────┼─────────────────────────┤ │ │3) Purpose │ │ │ ├─────────┼─────────────────────────┤ │ │4) Importance │ │ │ ├─────────┼───┬──────┬──────┬───────┤ │ │5) Scale │Gross Floor Area│m2 │Number of Floors (Height) │ / ( m) │ │ ├─────────┼───┴──────┴──────┴───────┤ │ │6) Design Standard │ │ │ ├─────────┼─────────────────────────┼───────┤ │7) Structural Planning │Establishment of a common classification system for structural systems │ │ ├─────────┼────────┬──┬─────┬───────┼───────┤ │8) Soil and Foundation │GroundClassification │ │ GroundwaterLevel │ │ │ │ ├────────┴──┴─────┴───────┤ │ │ │Basic Format │ │ │ ├────────┬──┬─────┬───────┤ │ │ │Bearing Capacity Foundation │Design Bearing Capacity│FileBasics │AppliedFileDiameter= │ │ │ │ │fe= t/m2 │ │ fp = ton │ │ ├─────────┼────────┼──┼─────┼───────┼───────┤ │9) Wind Load Overview │Default Wind Speed ​​ │V0=(m/sec)│Nopungdo │A, B, C, D │ │ │ ├────────┼──┼─────┼───────┤ │ │ │ │Gf │Importance Coefficient│Iw= │ │ ├─────────┼────────┼──┴┬────┴───────┼───────┤ │10) Wind Load Analysis │ │X Direction│Y Direction │ │ │Result ├────────┼───┼────────────┤ │ │ │Highest Floor Displacement │δx-max│δy-max │ │ │ ├────────┼───┼────────────┤ │ │ │Maximum Inter-story Displacement │Δx,max│Δy,max │ │ ├─────────┼────────┴───┴────────────┼───────┤ │11) Seismic Design Overview │Earthquake according to the "Rules on Structural Standards for Buildings" and "Architectural Structural Standards"│ │ │ │Requirements for Load Calculation │ │ │ ├────────┬────────────────┼───────┤ │ │Interpretation Method │Seismic Design Categories(A,B,C,D) │ │ │ │ ├────────────────┤ │ │ │ │Equivalent Static Analysis Method, Dynamic Analysis Method │ │ │ ├────────┼───┬─────┬──────┼───────┤ │ │Importance Coefficient │IE= │BuildingEffective │W= │ │ │ │ │ │Weight │ │ │ ├─────────┼────────┼───┼─────┴──────┼───────┤ │12) Basic Seismic Resistance│ │X Direction│Y Direction │structural system │ │system ├────────┼───┼────────────┤Common Classification for │ │ │Lateral Force Resistance System │ │ │System Establishment │ │ ├────────┼───┼────────────┤ │ │ │Reaction modification factor │Rx= │Ry= │ │ │ ├────────┼───┼────────────┤ │ │ │Excess Strength Factor │Ωox= │Ωoy= │ │ │ ├────────┼───┼────────────┤ │ │ │Displacement Amplification Factor │Cdx= │Cdy= │ │ │ ├────────┼───┴────────────┤ │ │ │Allowable Inter-story Displacement │Δax= (0.010 hs,0.015hs,0.020hs)│ │ ├─────────┼────────┼───┬────────────┼───────┤ │13) Main Seismic Design │ │X Direction│Y Direction │ │ │Result ├────────┼───┼────────────┤ │ │ │Seismic Response Coefficient │CSx= │CSy= │ │ │ ├────────┼───┼────────────┤ │ │ │Base Shear Force │VSx= │VSy= │ │ │ ├────────┼───┼────────────┤ │ │ │ApproximateEssentialPeriod │Tax= │Tay= │ │ │ ├────────┼───┼────────────┤ │ │ │Maximum Inter-story Displacement │Δx,max│Δy,max │ │ ├─────────┼────────┼───┼────────────┼───────┤ │14) Eigenvalue Analysis │ │Vibration Period│Mass Participation Rate │ │ │ (During Dynamic Analysis) ├────────┼───┼────────────┤ │ │ │1stMode │Sec │% │ │ │ ├────────┼───┼────────────┤ │ │ │2ndMode │Sec │% │ │ │ ├────────┼───┼────────────┤ │ │ │3rdMode │Sec │% │ │ ├─────────┼───────┬┴───┼────────────┼───────┤ │15) Structural Element Seismic │Special Seismic Load │Piroti │Yes, No │ │ │Design Review Items │ApplyStatus ├────┼────────────┤ │ │ │ │Outside misalignment│Yes, No │ │ │ │ ├────┼────────────┤ │ │ │ │Lateral force resistance of vertical element │Yes, No │ │ │ │ │Discontinuous │ │ │ │ ├───────┴────┼────────────┤ │ │ │Vertical System Discontinuous │Yes, No │ │ ├─────────┼─────────┬──┴────────────┼───────┤ │16) Non-structural elements │Non-structural elements of architecture │ │In the construction phase │ │ ├─────────┼───────────────┤requiring verification │ │ │Mechanical·Electrical │ │Non-structural elements │ │ │Non-structural elements │ │Entry │ ├─────────┼─────────┴───────────────┼───────┤ │17) Special Notes │ │ │ ├─────────┴─────────────────────────┴───────┤ │ Pursuant to Article 48 of the Building Act and Article 32 of the Enforcement Decree of the same Act, the confirmation certificate of structural safety and seismic design of the subject building │ │Submitting. │ │ │ │ Year month day │ │ │ │ Author: Architectural Structural Engineer ?? Designer: Architect ?? │ │ week : week SO: │ │ Contact: Contact: │ └───────────────────────────────────────────┘ 210㎜×297㎜[White Paper (80g/㎡)]