Annex 4 — 하수도법 시행령

286151 · 2026-06-03

■ Enforcement Decree of the Sewerage Act [Appendix 4] <Amended Dec. 23, 2025> Registration Standards for Private Sewage Treatment Facility Design and Construction Businesses (Related to Article 31, Paragraph 1) ┏━━━━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━┓ ┃Facilities and Equipment │TechnicalPersonnel ┃ ┠────────────────────┼───────────────────┨ ┃A. Office and Laboratory │a. Industrial Engineer in Civil Engineering or Industrial Engineer in Architecture ┃ ┃or. Experimental equipment capable of measuring the following items │상의 자격을 가진 자 1명 이상 ┃ ┃1) Biochemical Oxygen Demand │B. General Mechanical Engineer, Lubrication Management Industrial Engineer, Computer┃ ┃2) Chemical Oxygen Demand │Computer-Applied Machining Technician, Construction Machinery & Equipment ┃ ┃3) Suspended matter │Industrial Engineer, Precision Measurement Industrial Engineer, Mechanical Assembly ┃ ┃Total Nitrogen (TN) and Total Phosphorus (TP) │Industrial Engineer, Electric Industrial Engineer, or Electric ┃ ┃5) Number of E. coli colonies │with qualifications of Industrial Engineer in Construction or higher ┃ ┃6) Chloride ion concentration │1 or more people ┃ ┃. One or more sets of equipment and drafting facilities or drafting │. Water Quality Environmental Technician or Chemical Engineering Technician ┃ ┃1 computer capable of design (CAD) │At least 2 persons with qualifications of company level or higher ┃ ┃or more │ ┃ ┗━━━━━━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━┛ Remarks: 1. The qualifications specified in the technical personnel section are in accordance with Article 10, Paragraph 1 of the "National Technical Qualifications Act" . 2. Construction engineers [are] graded pursuant to Item 2, Subparagraph (b) of Annex 1 of the Enforcement Decree of the Construction Technology Promotion Act is entry-level or higher, and the job field according to Item 3 of the same table is the technical personnel column , the standards for the relevant technical personnel It is deemed to be equipped with the necessary qualifications, provided that among the technical personnel in the table above, a Water Quality Environmental Industrial Engineer or higher corresponding to (Water Quality Environmental Industrial Engineer, Water Quality Environmental Engineer, Water Quality Management Professional Engineer) Regarding technical personnel, in accordance with Item 3 of Annex 1 of the Enforcement Decree of the Construction Technology Promotion Act Applicable only if the specialized field corresponds to water quality management pursuant to subparagraph 2) of the same subparagraph. It is deemed to meet the standards for technical personnel. 2-2. The representative of an institution, corporation, or organization, or a sole proprietor, technical personnel according to the table above (including cases recognized as technical personnel pursuant to Note 2 The representative or sole proprietor is included in the calculation of technical personnel in (shall be performed). 2-3. Where one person falls under two or more of the technical personnel according to the table above (Remarks Even in cases where they are recognized as technical personnel pursuant to Subparagraph 2) one of them Includes only in the calculation of technical personnel. 3. Any person falling under any of the following subparagraphs in the private sewage treatment facility design and construction business , one person among the facilities, equipment, and common technical personnel may not be provided in duplicate, and notwithstanding Note 2-3, one person 2 If you hold a certification of Type 2 or higher, limit it to Type 2 qualifications. It is considered to be equipped with personnel. a. A person who has registered for the business of manufacturing private sewage treatment facilities pursuant to Article 52 of the Act b. A person who has registered for the private sewage treatment facility management business pursuant to Article 53 of the Act . Pursuant to Article 28, Paragraph 1, Subparagraph 3 of the "Act on the Management and Utilization of Livestock Manure" Person who has obtained a permit for livestock manure facility management business . Delete <2022. 1. 4.> E. Delete <2022. 1. 4.> 4. With respect to each measurement item, Article 16 of the “Act on Testing and Inspection, etc. in the Environmental Field” , during the contract period, the same item may not be provided, and all measurement items department, during the same contract period, experimental equipment and A laboratory may not be provided. 5. In the case of using experimental equipment and drafting facilities by entering into a lease agreement It is deemed to be equipped with the relevant equipment. In this case, experimental instruments and drafting facilities shall be deemed to be equipped with the relevant equipment. It must be used exclusively for startups.