Annex 1 — 하수도법 시행령

286151 · 2026-06-03

■ Enforcement Decree of the Sewerage Act [Table 1-4] <Amended May 27, 2025> Classification and Registration Requirements for Specialized Technical Diagnosis Institutions (Related to Article 17, Paragraph 1) 1. Specialized Agency for Public Sewerage Technical Diagnosis a. Equipment: At least one unit each. However, portable flow meters shall be at least three units. 1) Tachometer 2) Water temperature gauge 3) Hydrogen Ion Concentration (pH) Meter 4) Dissolved Oxygen (DO) Detector 5) Automatic Sample Collector 6) Digital Pressure Gauge 7) Grounding Resistance Meter 8) Insulation Resistance Tester Closed-circuit television (CCTV) equipment 10) Smoke Test Blower 11) Portable Flow Meter 12) Biochemical Oxygen Demand (BOD) Experimental Analysis Equipment 13) Total Organic Carbon (TOC) Experimental Analysis Equipment 14) Suspended Solids (SS) Experimental Analysis Equipment 15) Total Nitrogen (TN) Experimental Analysis Equipment 16) Total Phosphorus (TP) Laboratory Analysis Equipment 17) Total Coliform Count Experimental Analysis Equipment 18) Ecotoxicology Analysis Equipment 19) Oxidation-Reduction Potential (ORP) Meter 20) MLSS (Mixed Liquor Suspended Solid) Meter 21) Vibration Measurement Analyzer 22) Noise Meter 23) Tachometer 24) Portable Calibrator 25) Power Quality Analyzer 26) Flowmeter B. Technical Manpower 1) At least one person corresponding to the following a) or b) a) PhD in Environmental, Chemical, Mechanical, or Electrical Engineering b) Water supply and sewage, water quality management, waste treatment, chemical engineering, construction machinery, industrial machinery and equipment, power transmission and distribution, Professional Engineer in Electrical Applications or Industrial Instrumentation and Control 2) At least one engineer for each of the following regulations (a) through (d) a) Water Quality Environment, Waste Treatment, Chemical Engineering, Chemical Analysis, or Biochemical Product Manufacturing Engineer b) General machinery, construction machinery and equipment, HVAC and refrigeration machinery, or equipment maintenance engineer d) Electric or Electric Work Engineer d) Civil Engineering or Water Quality Environmental Engineer At least one Industrial Engineer for each of the following provisions from a) to e) a) Water Quality Environment or Waste Treatment Industrial Engineer b) Machine assembly, machine design, precision measurement, construction machinery and equipment, HVAC and refrigeration machinery or equipment maintenance Industrial Engineer D) Industrial Engineer in Electricity or Electrical Construction d) Civil Engineering Industrial Engineer E) Water Quality and Environment Industrial Engineer At least one Certified Environmental Measurement Analyst 2. Specialized Technical Diagnosis Agency for Sewer Pipelines (excluding relay pumping stations) a. Equipment: At least one unit each. However, portable flow meters shall be at least three units. 1) Tachometer 2) Water temperature gauge 3) Hydrogen Ion Concentration (pH) Meter 4) Dissolved Oxygen (DO) Detector 5) Automatic Sample Collector 6) Digital Pressure Gauge 7) Grounding Resistance Meter 8) Insulation Resistance Tester Closed-circuit television (CCTV) equipment 10) Smoke Test Blower 11) Portable Flow Meter 12) Biochemical Oxygen Demand (BOD) Experimental Analysis Equipment B. Technical Manpower 1) At least one person corresponding to the following a) or b) a) Ph.D. in Water Supply and Sewerage or Water Quality Related Fields b) Professional Engineer in Water Supply and Sewerage or Water Quality Management At least one Civil Engineer or Water Quality and Environmental Engineer At least one Industrial Engineer in Civil Engineering or Water Quality & Environmental Engineering At least one person with a Mechanical or Electrical Industrial Engineer license At least one Certified Environmental Measurement Analyst Remarks 1. If equipment equipped with complex measurement functions is available, the target that can be measured with said equipment . Closed-circuit television (CCTV) equipment is available for lease, and the equipment required for ecotoxicology analysis In the case of equipment and personnel, pursuant to Article 16, Paragraph 1 of the "Act on Testing and Inspection, etc. in the Environmental Field," Equipment and personnel required when entering into a joint use agreement with a water quality measurement agency in accordance with . Technical personnel refers to persons who have acquired a national technical qualification pursuant to Article 10, Paragraph 1 of the National Technical Qualifications Act. MTQf42bae3f9fdb080a00534refers to START. 4. A Ph.D. or Professional Engineer has worked in the relevant field for at least 7 years after obtaining an Engineer qualification in the relevant field Persons who have obtained a master's degree in a related field and have worked in the water and sewage sector for more than 6 years, General civil servants pursuant to the "National Civil Service Act" and the "Local Civil Service Act" or "of public institutions As an employee of a public institution pursuant to Article 4 of the Act on the Operation of Public Institutions, with 15 years of experience in an environment-related field and performed practical work in the water supply and sewage field for more than 3 years. An Engineer is a person who has worked in the relevant field for at least 3 years after obtaining an Industrial Engineer qualification in the relevant field. . An Industrial Engineer is a person who has worked in the relevant field for at least 3 years after obtaining a Craftsman qualification in that field. . Environmental Measurement and Analysis Specialists specialize in water quality environment, waste treatment, chemical engineering, chemical analysis, and biochemical product manufacturing. It may be replaced by a person with at least one year of practical experience in analysis from the company. 8. Except for the remarks, the civil engineering and water quality/environmental qualification categories under Subparagraph 2, Item (b) 2) and Subparagraph 3) of the same item are mutually Must not be duplicated. 9. A management agency pursuant to Article 19-2, Paragraph 1, Subparagraph 1 of the Act intends to register as a specialized technical diagnostic institution , common equipment may not be provided redundantly.