Annex 5 — 폐기물관리법 시행령
284591 · 2026-03-26
■ Enforcement Decree of the Waste Management Act [Table 5-2] <Amended Jan. 2, 2026>
Facilities, Equipment, and Technical Capabilities of Specialized Waste Analysis Agencies (Related to Article 10)
GeneralStandard
a. Technical personnel at specialized waste analysis institutions are on permanent duty (「Gender Equality in Employment and Work-Family
Reducing working hours during the childcare period pursuant to Article 19-2 of the Act on Support for Work-Life Balance
), and the person in charge and the person in charge are each separately two
should.
B. The calculation of technical personnel for specialized waste analysis institutions shall be in accordance with the following standards.
1) If the representative of the organization falls under the following, personnel calculation according to the following classification
.
a) Persons responsible pursuant to Subparagraph 2, Item (a) 3), Subparagraph (b) 3) or Subparagraph (c) 3) of Subparagraph 2
If meeting the qualification criteria and performing the duties of the relevant person in charge: Calculation of person in charge
b) The person in charge pursuant to Subparagraph 2, Item (a) 3), Subparagraph (b) 3) of the same subparagraph, or Subparagraph (c) 3) of the same subparagraph
In cases where the qualification criteria are met and the relevant person in charge performs their duties: Person in Charge Calculation
Persons whose qualifications have been suspended pursuant to the "National Technical Qualifications Act" and under the "Construction Technology Promotion Act"
Persons who have received a business suspension order are excluded from the calculation of technical personnel.
3) Even if a person holds two or more types of technical qualifications, one type of
Only technical qualifications are recognized and counted as one technical personnel.
Technical personnel from specialized waste analysis institutions are employed by other institutions or companies.
It must not be another specialized waste analysis institution (other specialized fields of the relevant institution )
) or technical personnel of companies other than specialized waste analysis institutions, duplicated
Must not register.
d. Among the facility standards, offices, laboratories, and equipment rooms must be separated.
e. Facilities and equipment must be used exclusively by the relevant waste analysis agency.
, and among the facilities, the offices, laboratories, and equipment rooms are leased (the lease agreement specifies the lease period
It can be used by obtaining notarization for 3 years or more. In this case, the []
If the contract period is changed or expires during the lease term, the amended lease agreement
must be resubmitted to the designated authority.
b. A person designated as a specialized waste analysis institution in the general field at the same location
As a specialized waste analysis agency in the field of polychlorinated biphenyls (PCBs), duplication
If you intend to obtain designation, facility standards in the field of polychlorinated biphenyls
and
must secure at least one manager and at least one person in charge, additionally technical personnel
.
Company. Measurement agency business pursuant to Article 16, Paragraph 3 of the "Act on Testing and Inspection, etc. in the Environmental Field"
at the same location in the general field or polychlorinated biphenyl field
In the case of seeking designation as a specialized waste analysis institution, common facilities and equipment are
May not be equipped in duplicate.
Standards for Facilities, Equipment, and Technical Capabilities by Specialized Field of Specialized Waste Analysis Agencies
a. General Field
1) Analysis Item
┌────┬───────────────────────────────┐
│Category │Analysis Items │
├────┼───────────────────────────────┤
│GeneralItem│Hydrogen ion concentration, moisture and solids, loss on ignition and organic matter content, oiliness │
│ │, Biological Oxygen Demand, Chemical Oxygen Demand, Suspended Solids │
├────┼───────────────────────────────┤
│Hazardous Substance│Lead or its compounds, copper or its compounds, arsenic or its compounds, │
│ │Mercury or its compounds, cadmium or its compounds, hexavalent chromium compounds, Si │
│ │Antioxidant compounds, organophosphorus compounds, volatile lower chlorinated hydrocarbons, normal hexane│
│ │Extracted substances, phenolic compounds, chromium or its compounds, soluble iron or its compounds│
│ │Water, zinc or its compounds, soluble manganese or its compounds, fluorinated compounds │
│ │Water, Total Coliform Count, Color, Ammoniacal Nitrogen, Inorganic Nitrogen, Total Phosphorus │
├────┼───────────────────────────────┤
│Organic Solvent│Dichloromethane, Trichloromethane, Tetrachloromethane, Dichlorodiflu│
│ │Oromethane, Trichlorofluoromethane, Dichloroethane, Trichloro-E │
│ │Tan, trichlorotrifluoroethane, trichloroethylene, tetrachloro│
│ │Ethylene, Chlorobenzene, Dichlorobenzene, Monochlorophenol, Dichlorophen │
│ │nol, 1,1-Dichloroethylene, 1,3-Dichloropropene, 1,1,2-Trichloro │
│ │-1,2,2-Trifluoroethane and other organic solvents │
└────┴───────────────────────────────┘
2) Facilities and Equipment
┌──┬────────────────────────────────┐
│Category│Facility and Equipment Name │
├──┼────────────────────────────────┤
│Facility│Equipped with all of the following facilities │
│ │a) Laboratory equipped with fume hood: 40 square meters or more │
│ │b) Equipment room equipped with constant temperature and humidity facilities: 40 square meters or more │
│ │) Office: 40 square meters or more │
├──┼────────────────────────────────┤
│Equipment│Equip yourself with all the following equipment. However, the equipment from (a) through (b) │
│ │The [bi] is [subject to] Article 6, Paragraph 1, Subparagraph 7 of the "Act on Testing and Inspection, etc. in the Environmental Field" │
│ │In the method of testing, inspection, etc. according to the Environmental Pollution Process Testing Standards for the waste sector │
│ │. │
│ │a) Gas chromatograph or gas chromatograph-mass spectrometer 1 │
│ │or more │
│ │b) One Guder na Danisch (KD) concentrator or rotary evaporator │
│ │on │
│ │d) 10 or more purification columns │
│ │d) 1 or more water baths │
│ │e) 1 or more distilled water generators │
│ │bar) 1 or more scales with 0.1mg increments │
│ │Company) One or more sample refrigerators capable of storage at 4℃ or below │
│ │A) Reciprocating shaker for dissolution (horizontal type, 200 rpm or higher) 1 unit │
│ │or later │
│ │) At least 1 unit each of the following systems │
│ │ (1) 0.5mm sieve made of iron │
│ │ (2) 5mm sieve made of iron │
│ │ (3) 0.5mm sieve of non-ferrous material │
│ │ (4) 5mm sieve of non-ferrous material │
│ │차) 1 or more dryers with a temperature range from 50℃ to 200℃ │
│ │Ka) One or more muffle furnaces with a temperature range of 200℃ to 700℃ │
│ │) 1 or more pH meters │
│ │Part) Distillation apparatus set (for cyanide) 1 or more │
│ │(Bottom) Atomic Absorption Spectrophotometer (AAS) or Inductively Coupled Plasma Atomic Emission Spectrometer │
│ │System (ICP) 1 or more │
│ │) 1 or more magnetic stirrers │
│ │) 1 or more electric heating plates │
│ │(more) 1 or more UV and visible spectrometers │
│ │) Incubator (for BOD analysis) 1 or more │
│ │mer) Sample extraction device (as a separatory funnel shaking extractor with 200 rpm or more │
│ │thing) 1 or more │
│ │) 1 or more Soxhlet extraction machines │
└──┴────────────────────────────────┘
3) Technical Capability
┌───┬─────────────────────────────┐
│Classification │QualificationCriteria │
├───┼─────────────────────────────┤
│Manager│Must have at least one person who meets any of the following criteria │
│ │a) Obtain a doctoral degree or technical skills in an environmental or analytical field │
│ │Person who has obtained the qualification of a Certified Specialist or Environmental Measurement and Analysis Specialist │
│ │b) After obtaining a master's degree in an environment or analysis-related field, waste division │
│ │Person with 2 years or more of work experience │
│ │d) After obtaining the Environmental Engineer qualification in the field of waste, water quality, or soil, waste│
│ │Person with at least 2 years of experience in equipment analysis │
│ │d) Environmental or analytical management at a school pursuant to Article 2 of the Higher Education Act│
│ │Obtaining a bachelor's degree in a related field (a level equivalent to this under other laws │
│ │(including cases where it is recognized that there is an educational background higher than or equal to that) │
│ │Person with at least 5 years of experience in waste analysis work │
├───┼─────────────────────────────┤
│Contact│Must have at least two persons who meet any of the following criteria │
│ │a) A master's degree in an environment or analysis-related field, or in waste, water quality or│
│ │is a person who has obtained the Environmental Engineer qualification in the soil field │
│ │b) Environmental or analytical management at schools pursuant to Article 2 of the Higher Education Act│
│ │Obtaining a bachelor's degree in a related field (a level equivalent to this under other laws │
│ │(including cases where it is recognized that there is an educational background higher than or equal to that) │
│ │Person with at least 1 year of experience in waste analysis work │
│ │d) Environmental or analytical management at a school pursuant to Article 2 of the "Higher Education Act"│
│ │Acquisition of a professional associate degree in a related field (such as under other laws) │
│ │are recognized │
│ │A person with at least 3 years of experience in waste analysis work after completing (). │
└───┴─────────────────────────────┘
B. Polychlorinated Biphenyl Field
1) Analysis Item: Polychlorinated Biphenyl
2) Facilities and Equipment
┌──┬────────────────────────────────┐
│Category│Facility and Equipment Name │
├──┼────────────────────────────────┤
│Facility│Equipped with all of the following facilities │
│ │a) Laboratory equipped with fume hood: 40 square meters or more │
│ │b) Equipment room equipped with constant temperature and humidity facilities: 40 square meters or more │
│ │) Office: 40 square meters or more │
├──┼────────────────────────────────┤
│Equipment│Equip yourself with all the following equipment. However, the equipment from (a) through (t) │
│ │The [problem] is [subject to] Article 6, Paragraph 1, Subparagraph 7 of the "Act on Testing and Inspection, etc. in the Environmental Field" │
│ │In the method of testing, inspection, etc. according to the Environmental Pollution Process Testing Standards for the waste sector │
│ │. │
│ │a) Gas chromatography or gas chromatograph-mass spectrometer │
│ │1 or more │
│ │b) One or more Guder na Danish concentrators or rotary evaporators │
│ │d) 10 or more purification columns │
│ │ra) 1 or more bathtubs │
│ │e) 1 or more distilled water generators │
│ │bar) 1 or more scales with 0.1mg increments │
│ │Company) One or more sample refrigerators capable of storage at 4℃ or below │
│ │A) Reciprocating shaker for dissolution (horizontal type, 200 rpm or higher) 1 unit │
│ │or later │
│ │) At least 1 unit each of the following systems │
│ │ (1) 0.5mm sieve made of iron │
│ │ (2) 5mm sieve made of iron │
│ │ (3) 0.5mm sieve of non-ferrous material │
│ │ (4) 5mm sieve made of non-ferrous material │
│ │) Sample extraction device (vertical shaker extractor with 200 rpm or more) 1 │
│ │or more │
│ │Ka) 1 or more Soxhlet extraction devices │
│ │T) 1 or more reflux chillers │
└──┴────────────────────────────────┘
┌───┬──────────────────────────────┐ 3) Technical Capability
│Classification │QualificationCriteria │
├───┼──────────────────────────────┤
│Manager│Must have at least one person who meets any of the following criteria │
│ │ a) Obtain a doctoral degree or technical skills in an environmental or analytical field │
│ │Person who has obtained the qualification of a Certified Specialist or Environmental Measurement and Analysis Specialist │
│ │ b) After obtaining a master's degree in an environment or analysis-related field, waste division │
│ │Person with 2 years or more of work experience │
│ │ d) After obtaining the Environmental Engineer qualification in the field of waste, water quality, or soil, waste│
│ │Person with at least 2 years of experience in equipment analysis │
│ │ d) Environmental or analytical management at a school pursuant to Article 2 of the Higher Education Act│
│ │Obtaining a bachelor's degree in a related field (a level equivalent to this under other laws │
│ │(including cases where it is recognized that there is an educational background higher than or equal to that) │
│ │Person with at least 5 years of experience in waste analysis work │
├───┼──────────────────────────────┤
│Contact│Must have at least two persons who meet any of the following criteria │
│ │ a) Master's degree in an environment or analysis-related field, or in waste, water quality │
│ │or a person who has obtained the Environmental Engineer qualification in the soil field │
│ │ b) Environmental or analytical management at schools pursuant to Article 2 of the Higher Education Act│
│ │Obtaining a bachelor's degree in a related field (a level equivalent to this under other laws │
│ │(including cases where it is recognized that there is an educational background higher than or equal to that) │
│ │Person with at least 1 year of experience in waste analysis work │
│ │ d) Environmental or analytical management at a school pursuant to Article 2 of the "Higher Education Act"│
│ │Acquisition of a professional associate degree in a related field (such as under other laws) │
│ │are recognized │
│ │A person with at least 3 years of experience in waste analysis work after completing the above. │
└───┴──────────────────────────────┘
. Asbestos field
1) Analysis Item: Asbestos
2) Facilities and Equipment
┌──┬────────────────────────────────┐
│Category│ Facility and Equipment Name │
├──┼────────────────────────────────┤
│Facility│Equipped with all of the following facilities │
│ │ a) Laboratory equipped with fume hood: 30 square meters or more │
│ │ b) Equipment room equipped with constant temperature and humidity facilities: 30 square meters or more │
│ │ ) Office: 30 square meters or more │
├──┼────────────────────────────────┤
│Equipment│Equip yourself with all the following equipment. However, the equipment from a) to d) │
│ │The [bi] is [subject to] Article 6, Paragraph 1, Subparagraph 7 of the "Act on Testing and Inspection, etc. in the Environmental Field" │
│ │In the method of testing, inspection, etc. according to the Environmental Pollution Process Testing Standards for the waste sector │
│ │. │
│ │ a) One or more Polarizing Microscopes (PLM) │
│ │ b) One or more X-ray diffraction analyzers (XRD) │
│ │ ) Transmission Electron Microscope (TEM-EDS) or Scanning Electron Microscope (SEM-EDS) │
│ │1 or more │
│ │ d) One or more asbestos sample collection and pretreatment devices │
└──┴────────────────────────────────┘
3) Technical Capability
Health, Environmental Health, Environmental Engineering, Industrial Hygiene, Industrial Safety, Applied Geology, Soil Environment, Waste
Asbestos-related fields and majors such as water, earth science, geology, mineralogy, etc., atmosphere, water quality, etc.
In the field/major of Criminology, or in the field/major of Chemistry/Chemical Engineering, corresponding to the following classifications
Secure personnel respectively
┌───┬───────────────────────────────┐
│Section │QualificationCriteria │
├───┼───────────────────────────────┤
│Manager│Must have at least one person holding a doctoral degree or Professional Engineer qualification. │
├───┼───────────────────────────────┤
│Contact│Must have at least two persons who meet any of the following criteria │
│ │ 1) Person who has obtained engineer qualification │
│ │ 2) Obtaining a bachelor's degree from a school pursuant to Article 2 of the "Higher Education Act" (other │
│ │Under the law, recognizing that one has an educational background of this level or higher │
│ │(including cases where it is determined) after having 1 year of experience in asbestos-related analysis work │
│ │People who are more than │
│ │ 3) Acquiring an associate degree from a school pursuant to Article 2 of the Higher Education Act │
│ │(Under other laws, there is an educational background of the same level or higher │
│ │(including cases recognized as such) experience in asbestos-related analysis work after │
│ │People who have been here for 3 years or more │
└───┴───────────────────────────────┘