Annex 2 — 특수학교시설ㆍ설비기준령
284895 · 2026-03-24
■ Decree on Standards for Facilities and Equipment in Special Schools [Appendix 2] <Newly Inserted Dec. 5, 2016>
Types and Standards of Facilities and Equipment for Safety and Convenience (Related to Article 5)
┌───────────┬───────────────────────────────┐
│Types of Facilities and Equipment │InstallationCriteria │
├───────────┼───────────────────────────────┤
│ 1. Pedestrian walkway │a. In the following places, continuous pedestrian walkways so as not to obstruct passage │
│ │. │
│ │ 1) From the school gate to the main entrance of the main school building │
│ │ 2) From the school bus boarding/alighting area to the main teacher │
│ │ 3) Between Teachers │
│ │b. The effective width of the main pedestrian walkway must be at least 1.8 meters. However, │
│ │In the case of a pedestrian walkway installed under subparagraph 2), the effective width shall be 1.2 meters │
│ │. │
│ │. If there is a difference in floor height, wheelchair passage is obstructed │
│ │, and the sloped part of the floor surface │
│ │The slope must be 1/18 or less. However, terrain, etc. │
│ │In cases where it is difficult to make the slope 1/18 or less, │
│ │It can be installed at 1/12 or less. │
│ │Ra. Raise it by at least 10 centimeters above the roadway, or make it curb, flowerbed, or │
│ │is separated from the roadway by methods such as installing safety railings │
│ │must be. │
│ │e. Rain shelters must be installed on pedestrian walkways specified in subparagraphs 2) and 3) of item a. │
│ │must be installed. │
├───────────┼───────────────────────────────┤
│ 2. School Bus Stop/Alighting Area │a. When school buses park or turn around, interference with the pedestrian walkway a. │
│STATION │It must be installed in a location where it will not occur. │
│ │a. Install a collision prevention device at the end of the boarding and alighting area. │
│ │must. │
│ │. To the teacher's entrance or elevator facilities accessible to wheelchairs │
│ │It must be installed in an easily accessible location. │
│ │. Standing pillars around the boarding/alighting area indicating that it is a boarding/alighting area │
│ │type or wall-mounted type guide signs must be installed. │
│ │E. A space where wheelchair users can board, alight, and wait for boarding/alighting │
│ │Space must be secured, and the floor surface must be at least 4.5 meters wide (차 │
│ │Parking area 3.3 meters or more, boarding/alighting waiting area 1.2 meters │
│ │or more), must be at least 13 meters in length. │
│ │bar. In the event of a height difference on the floor surface, │
│ │It must be at the START level, and the slope of the bottom surface must be 1/50 or less. │
│ │must be completed, and boarding and alighting areas must be created on the floor surface as shown in the figure below │
│ │A distinguishable mark must be provided. │
│ │ │
├───────────┼───────────────────────────────┤
│3. Main entry and exit of teachers, etc. │a. There must be no difference in height of the floor surface. │
│old │a. The entrance section should be installed without separate ramps and stairs as much as possible. │
│ │, provided that if the bottom surface is sloped, the slope is 1/18 │
│ │must be less than or equal to. │
│ │Doors should be installed considering the characteristics of the school, but finger pinch prevention devices │
│ │must be attached, and in the case of a glass door, collision prevention │
│ │Color strips, etc. must be installed for this purpose. │
├───────────┼───────────────────────────────┤
│4. Corridor │a. The effective width must be at least 2.4 meters. │
│ │b. There must be no fixed obstacles obstructing passage. │
│ │. Wheelchair storage, rehabilitation tool storage, fire extinguisher storage, drinking fountain │
│ │In the case of installing facilities such as shoe racks or similar equipment in the hallway, on the wall... │
│ │Mandatory measures must be taken to avoid obstructing traffic, such as landfilling. │
│ │Wall corners or column corners exposed in hallways minimize safety accidents. │
│ │Make it rounded so that it can be extinguished, or a separate collision avoidance device │
│ │or a safety device must be attached. │
│ │E. Handles shall be installed considering the student's growth and development process, and │
│ │It can be installed in duplicate if necessary. │
├───────────┼───────────────────────────────┤
│5. Classroom Door │a. Having a sliding or hinged structure, and having an effective width of 1.0 meter or more │
│ │should. │
│ │a. Doors must not have thresholds and must be equipped with finger pinch guards. │
│ │must. │
│ │. Door handles must be installed as a protruding type. │
│ │. Partially using see-through material on the doorway... │
│ │You must enable viewing the opposite side through the START statement. │
├───────────┼───────────────────────────────┤
│6. Stairs │a. Use of stairs and landings (excluding the last tread portion) │
│ │The effective width must be at least 1.5 meters. │
│ │a. The stair nodules shall be finished with a non-slip material, and │
│ │Easily recognize stair edges by using a different color from the treads │
│ │must be made possible. │
│ │The stair handrails are wall-mounted or handrail-type on both sides of the stairs. │
│ │must be installed, and the end of the handle, sleeves, etc. │
│ │It must be finished with a structure that does not get caught. │
│ │Ra. Handrail │
│ │ 1) In cases where the handrail and handrail are integrated, there are no railing bars │
│ │is plate type or vertical handrail type (stair last tread part │
│ │is 10 centimeters │
│ │It must be installed as (limited to meters or less). │
│ │ The height of the handrail must be at least 1.2 meters from the floor surface. │
│ │and the height of the handrail at the landing and the last tread of the stairs │
│ │must be at least 1.5 meters from the floor surface. │
├───────────┼───────────────────────────────┤
│7. Elevator │a. One or more of the elevators have a floor surface with a width of 1.6 meters or more, │
│ │The length must be at least 2.3 meters. │
│ │a. By installing part or all of the elevator doors transparently │
│ │Must be able to see the other side through the elevator door │
│ │. │
│ │The elevator doors are equipped with both impact sensors and infrared sensors. │
│ │should. │
├───────────┼───────────────────────────────┤
│8. Ramp │a. The effective width of the ramp must be at least 1.5 meters. │
│ │b. If the ramp has a bend, the width and length of the bottom surface │
│ │must be at least 2 meters. │
│ │Considering the direction of travel on the slope, the possibility of a pedestrian colliding is . │
│ │Impact-absorbing mats must be installed on walls and railings, etc. │
│ │d. The bottom surface of the ramp shall be made of a non-slip material. │
├───────────┼───────────────────────────────┤
│9. Emergency Evacuation Space │a. Balconies or floors connected to classrooms, taking into account the building structure │
│ │Emergency evacuation spaces in the form of shared terraces must be installed │
│ │. │
│ │b. Locations easily accessible to rescue vehicles and rescue equipment, etc. and │
│ │must be tightened. │
├───────────┼───────────────────────────────┤
│10. window │Allows for easy evacuation to the outside in emergency situations, but normally the window │
│ │It must be a structure that prevents it from falling out. │
├───────────┼───────────────────────────────┤
│11. Other facilities/installations │a. Stages and platforms in indoor auditoriums and gymnasiums, or assembly platforms in sports fields, etc. │
│non │It must be a structure that allows direct access for wheelchair users. │
│ │a. The guardhouse (including the security office and the information office) is located where the school gate is well visible │
│ │. │
│ │. In the case of restrooms, there must be at least one toilet for every two classes, and urinals are │
│ │Considering the number of students, an appropriate number must be installed. │
│ │. │
│ │d. In the case of the teachers' lounge, changing room, bathroom, and parents' waiting room │
│ │In principle, at least one room shall be installed in each area, provided that school rooms │
│ │Depending on the START, some or all may not be installed. │
└───────────┴───────────────────────────────┘
Remarks: In addition to the above facilities, facilities and equipment necessary for the safety and convenience of students, such as faculty housing, etc.
can place.