Annex 1 — 감염병의 예방 및 관리에 관한 법률 시행령

285787 · 2026-05-06

■ Enforcement Decree of the Act on the Prevention and Control of Infectious Diseases [Appendix 1] <Amended Sep. 11, 2020> Designation Criteria for Central Infectious Disease Hospitals (Related to Article 1-3, Paragraph 2) 1. Facility Standards A. Negative Pressure Isolation Ward 1) Negative pressure isolation wards shall be installed by physically separating them from other areas within the hospital. 2) In negative pressure isolation wards, infectious disease patients, contaminated corpses, contaminated waste, etc. move Install contaminated pathways separately from general pathways. 3) From a negative pressure isolation ward, through air or drainage, other areas within the hospital and outside the building Install appropriate facilities to prevent the spread of infectious diseases. 4) Negative pressure isolation beds shall be installed in negative pressure isolation wards according to the following classifications. a) General negative pressure isolation beds are 80 or more for the purpose of diagnosis and treatment of patients with infectious diseases, etc. . b) Negative pressure isolation beds for intensive care are for the purpose of the medical diagnosis and treatment of patients with severe infectious diseases, etc. Install at least 20% of the number of general negative pressure isolation beds. High-pressure isolation wards are for infections with a high risk of infection, such as diseases of unknown etiology or novel infectious diseases. At least four shall be installed for the purpose of diagnosis and treatment of patients, etc. B. Negative pressure isolation bed 1) General negative pressure isolation beds shall secure an area of ​​at least 18 square meters per bed. 2) Negative pressure isolation beds for intensive care units shall secure an area of ​​at least 20 square meters per bed. High-pressure isolation wards are located in the districts that have general negative pressure isolation wards and intensive care negative pressure isolation wards. Installed independently, separate from the station, and expand the area to at least 25 square meters per bed See. . Other facilities 1) Install two or more operating rooms equipped with negative pressure systems. 2) Bio-Safety Level 3 ( BSL 3) Install the above examination rooms. 2. Manpower Standards a. Doctor Employ at least 10 specialists, including each of the following specialists. 1) At least 6 specialists in infectious disease-related fields 2) At least 2 specialists capable of operating extracorporeal membrane oxygenation (ECMO) B. Nurse Employ 21 or more nurses. 3. Equipment Standards: At least one of each of the following items must be provided. a. Extracorporeal circulation device B. Ventilator . Extracorporeal Membrane Oxygenation . Mobile video recording device E. Computed Tomography B. Testing equipment for microorganisms, viruses, etc. 4. Operating Standards a. Unidentified cause, novel infectious disease, infectious disease patients, etc., or sources of contamination such as infectious disease pathogens, etc. to other patients, guardians, and staff, etc., related facilities and personnel Installs and operates power, equipment, etc. a. At least the number of beds determined and notified by the Minister of Health and Welfare among the total number of negative pressure isolation beds Operated as reserve beds for infectious disease preparedness, so that in the event of an outbreak of an infectious disease patient, etc. Enables medical diagnosis and treatment without the need for a body part. In the event of an infectious disease crisis, rapidly expand hospital beds and response personnel in accordance with the crisis response manual. However, respond in close cooperation with the Ministry of Health and Welfare and the Korea Disease Control and Prevention Agency. . A 24-hour on-call system consisting of two specialists is operated. E. In addition, if the Minister of Health and Welfare deems it particularly necessary for the prevention and management of infectious diseases, etc. It shall be operated in accordance with the procedures and methods recognized and notified as such. non GO 1. Facility standards, personnel standards, and equipment standards pursuant to the provisions of Items 1 through 4 of the above table Detailed matters necessary for the START and operational standards shall be determined and announced by the Minister of Health and Welfare. 2. When the Minister of Health and Welfare establishes a central infectious disease hospital pursuant to Article 8-2, Paragraph 1 of the Act shall follow the standards in the table above.