Annex 4 — 에너지이용 합리화법 시행령

286301 · 2026-05-28

■ Enforcement Decree of the Energy Rationalization Act [Appendix 4] <Amended Jan. 5, 2021> Designation Criteria for Diagnostic Institutions (Related to Article 39) 1. Equipment ┏━━━━━━━━━━━━━━━━━━━━━━━━━━━━┯━━━━━┯━━━━━━━━━━┓ ┃Contents │Type 1 │Type 2 ┃ ┣━━━━━━━━━━━━━━━━━━━━━━━━━━━━┿━━━━━┿━━━━━━━━━━┫ ┃ │ │ ┃ ┃ │ │ ┃ ┃ │ │ ┃ ┃a. Infrared thermal imaging camera │1 or more │Not applicable ┃ ┃ 1) Temperature: -20℃ ∼ 500℃ │ │ ┃ ┃ 2) Resolution: 0.1℃ │ │ ┃ ┃B. Ultrasonic flow meter │2 or more │1 or more ┃ ┃ 1) Capable of storing over 10,000 flow rate and velocity measurement data │ │ ┃ ┃ 2) Temperature: 0℃ ~120℃ │ │ ┃ ┃ 3) Pipe outer diameter: 50mm ~ 2,000mm │ │ ┃ ┃ 4) Flow speed: 0m/s ∼ 10m/s │ │ ┃ ┃. Digital pressure gauge │2 or more │1 or more ┃ ┃ 0bar ~ 30bar │ │ ┃ ┃. Data Logger │2 or more │1 or more ┃ ┃ 1) Write capacity: 512KB or more │ │ ┃ ┃ 2) Recording Channels: 5 or more │ │ ┃ ┃ 3) Temperature sensor: 5 or more units │ │ ┃ ┃E. Temperature and Hygrometer │2 or more │1 or more ┃ ┃ 1) Temperature: -10℃ ∼ 60℃ │ │ ┃ ┃ 2) Relative Humidity: 0% ~ 100% │ │ ┃ ┃B. Combustion Gas Analyzer │2 or more │1 or more ┃ ┃ 1) Carbon dioxide (CO2), oxygen (O2), carbon monoxide (CO), and nitrogen acid │ │ ┃ ┃Cargo (NOx) measurable │ │ ┃ ┃ 2) Temperature: -20℃ ~ 1,000℃ (Continuous measurement possible) │ │ ┃ ┃Company. Standard thermometer │1 set or more│1 set or more ┃ ┃ 1) Temperature: -50℃ ∼ 350℃ │ │ ┃ ┃ 2) Value per division: 0.1℃ │ │ ┃ ┃Ah. Thermometer │2 or more │1 or more ┃ ┃ 1) Temperature: -40℃ ∼ 300℃ │ │ ┃ ┃ 2) Resolution: 0.1℃ │ │ ┃ ┃ 3) Needle-type detector: 1 or more per unit │ │ ┃ ┃ 4) Surface contact type detector: 1 or more per unit │ │ ┃ ┃ │ │ ┃ ┃. High temperature thermometer │2 or more │1 or more ┃ ┃ 0℃ ~ 1,300℃ │ │ ┃ ┃. Infrared thermometer │2 or more │1 or more ┃ ┃ -30℃ ~ 400℃ │ │ ┃ ┃Car. Digital Anemometer │2 or more │1 or more ┃ ┃ 1) Wind speed: 0m/s ~ 50m/s │ │ ┃ ┃ 2) Temperature: 0℃ ∼ 300℃ │ │ ┃ ┃. Digital Pressure Gauge │2 or more │1 or more ┃ ┃ 1) Static pressure and differential pressure measurement possible │ │ ┃ ┃ 2) -1,000Pa ~ 3,000Pa │ │ ┃ ┃wave. Power Analyzer │2 or more │1 or more ┃ ┃ 1) Three-phase measurement possible │ │ ┃ ┃ 2) Voltage, current, power factor, harmonics, and power integration possible │ │ ┃ ┃ 3) Measurement data recording possible │ │ ┃ ┃H. AC Power Meter │2 or more │1 or more ┃ ┃ 1) Capable of measuring three-phase, active power, apparent power, reactive power, and power factor│ │ ┃ ┃ 2) Voltage: 0V ~ 600V │ │ ┃ ┃ 3) Current: 0A ∼ 1,000A │ │ ┃ ┃. Illuminance meter (brightness meter) │1 or more │1 or more ┃ ┃ 0lx ~ 20,000lx │ │ ┃ ┃tachometer │1 or more │1 or more ┃ ┃ 1) Contact and non-contact measurement possible │ │ ┃ ┃ 2) Contact: (1rpm) ~ 15,000rpm │ │ ┃ ┃ 3) Non-contact: (1rpm) ~ 90,000rpm │ │ ┃ ┃ ※ ( ) is a reference value │ │ ┃ ┃ │ │ ┃ ┃ │ │ ┃ ┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━┷━━━━━┷━━━━━━━━━━┛ 2. Technical Manpower ┏━━━━━━━━━━━━━━━━━━━━━━━━━━━━┯━━━━━┯━━━━━━━━━━┓ ┃Contents │Type 1 │Type 2 ┃ ┣━━━━━━━━━━━━━━━━━━━━━━━━━━━━┿━━━━━┿━━━━━━━━━━┫ ┃ │ │ ┃ ┃ │ │ ┃ ┃a. Mechanical, metal, chemical, and Cera under the National Technical Qualifications Act │1 or more people │Not applicable ┃ ┃Professional Engineer in the fields of Mechanics, Electricity, Architecture, or Energy, or Gas Technology │ │ ┃ ┃Person who has obtained the company qualification END │ │ ┃ ┃B. Energy Management Engineer and Gas Technician pursuant to the "National Technical Qualifications Act" │1 or more people │1 or more people ┃ ┃Company · Chemical Engineer · Electrical Engineer · Electrical Construction Engineer · Air Conditioning & Refrigeration Machinery │ │ ┃ ┃As a person who has obtained the qualification of Engineer or Building Equipment Engineer, 10 │ │ ┃ ┃Person with over 100 years of experience in the energy sector │ │ ┃ ┃It is the Energy Management Engineer and Gas Engineer under the National Technical Qualifications Act. │2 or more people │Not applicable ┃ ┃or a person who has obtained a Chemical Engineer qualification and has 7 years or more of energy │ │ ┃ ┃Person who performed work in the field │ │ ┃ ┃d. An Electric Engineer or Electric Construction Engineer pursuant to the National Technical Qualifications Act │2 or more people │Not applicable ┃ ┃qualification and has more than 7 years of experience in the energy sector │ │ ┃ ┃Person who performed the task │ │ ┃ ┃E. Energy Management Engineer and Gas Engineer pursuant to the National Technical Qualifications Act │1 or more people │1 or more people ┃ ┃or a person who has obtained a Chemical Engineer qualification and has been for 4 years or more │ │ ┃ ┃Person who has performed work in the energy field │ │ ┃ ┃B. Electrical Engineer or Electrical Construction Engineer pursuant to the National Technical Qualifications Act │1 or more people │1 or more people ┃ ┃qualification and has more than 4 years of experience in the energy sector │ │ ┃ ┃Person who performed the task │ │ ┃ ┃Company. Air Conditioning and Refrigeration Engineer or Architectural Engineer pursuant to the National Technical Qualifications Act│1 or more people │1 or more people ┃ ┃A person who has obtained the Equipment Engineer qualification and has more than 4 years of experience in the energy sector │ │ ┃ ┃The person who performed the duties of START │ │ ┃ ┃A. Mechanical, chemical, and ceramic/electrical qualifications pursuant to the National Technical Qualifications Act │1 or more people │1 or more people ┃ ┃Acquire engineer qualifications in the fields of engineering, architecture, energy, and safety management │ │ ┃ ┃person │ │ ┃ ┃ │ │ ┃ ┃ │ │ ┃ ┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━┷━━━━━┷━━━━━━━━━━┛ Remarks 1. Technical personnel must be full-time executives or employees of the relevant diagnostic institution. 2. Business in the energy sector refers to the manufacturing, installation, construction, control, diagnosis, and inspection of energy-using equipment and facilities, and refers to maintenance work. 3. Persons falling under category A of technical personnel include mechanical, chemical and ceramic, electrical, architectural, energy, and safety management A person who has obtained a Craftsman qualification in the relevant field and has performed duties in that field for 3 years or more Can digest. Among technical personnel, Engineers may be replaced by Industrial Engineers or Master Craftsmen in the same field, and energy or electric Articles in this field refer to the same field implemented by the Korea Energy Agency for the purpose of energy diagnosis. It can be replaced with an Energy Diagnostic Specialist. 5. If a person acquires two or more types of qualifications, they shall be deemed to possess technical competence in only one type. 6. Technical personnel under items (e) through (g) respectively new and renewable energy generation facilities (tae Replaced by a person who has obtained the Solar Power Engineer qualification and has performed work in the energy field for at least 4 years can do. 7. A person falling under any of the items regarding technical personnel cannot replace technical personnel under another item. 8. Registration standards for specialized energy conservation enterprises as stipulated in Article 25, Paragraph 1 of the Act, Article 30, Paragraph 2 of this Decree, and Annex 2 seeks designation as a diagnostic institution, of an energy conservation specialized enterprise The equipment and technical personnel possessed in accordance with the registration standards are the equipment and required at the time of designation as a diagnostic institution. Can be recognized as technical personnel.