Annex 8 — 시설물의 안전 및 유지관리에 관한 특별법 시행령
284791 · 2026-03-24
■ Enforcement Decree of the Special Act on Safety and Maintenance of Facilities [Appendix 8]
Safety Grade Standards for Facilities (Related to Article 12)
┌──────┬────────────────────────────┐
│SafetyRating │Condition of facilities │
├──────┼────────────────────────────┤
│1. A (Excellent) │Optimal, problem-free condition │
├──────┼────────────────────────────┤
│2. B (Good) │A minor defect occurred in the auxiliary member, but the performance of function is not limited │
│ │There are no parts requiring partial repair to enhance durability. │
│ │State │
├──────┼────────────────────────────┤
│3. C (Normal) │Minor defects in major members or extensive defects in auxiliary members │
│ │Although it occurred, there is no impediment to the overall safety of the facilities, and │
│ │Repairs are required on major components to prevent deterioration of durability and functionality.│
│ │or a state requiring simple reinforcement of auxiliary members │
├──────┼────────────────────────────┤
│4. D (Insufficient) │Defects have occurred in major members requiring urgent repair and reinforcement, and │
│ │State where a decision must be made regarding usage restrictions │
├──────┼────────────────────────────┤
│5. E (Defective) │Safety of facilities due to serious defects occurring in major members │
│ │There is a risk, so use is immediately prohibited and reinforcement or reconstruction is carried out. │
│ │MTQ014c4bc20535e22d01173State that must be START │
└──────┴────────────────────────────┘