Annex 15 — 물환경보전법 시행령

284747 · 2026-03-24

■ Enforcement Decree of the Water Environment Preservation Act [Attached Table 15] Method for Calculating Daily Excess Discharge and Daily Flow Rate (Related to Article 47, Paragraph 4) 1. Method for Calculating Daily Excess Emissions ┌─────────────────────────────────────────────────────────────────────────────────┐ │ Daily Excess Discharge = Daily Flow Rate × Concentration Exceeding Emission Limit × 10⁻⁶ │ └─────────────────────────────────────────────────────────────────────────────────┘ Remarks: 1. The concentrations exceeding the permissible emission standards are as follows: a. In the case of Article 41, Paragraph 1, Subparagraph 2, Item (a) of the Act: Emission concentration - Permissible emission standard concentration b. In the case of Article 41, Paragraph 1, Subparagraph 2, Item b of the Act: Emission concentration 2. The daily discharge amount of pollutants exceeding the permissible discharge standards for specific hazardous water substances shall be calculated to the fourth decimal place, and other water pollutants shall be calculated to the first decimal place. 3. The unit of discharge concentration shall be milligrams per liter (mg/L). 2. Method for Calculating Daily Flow Rate ┌─────────────────────────────────────────────────────────────────────────────────┐ │ Daily flow rate = Measured flow rate × Daily operating hours │ └─────────────────────────────────────────────────────────────────────────────────┘ Remark: 1. The unit of the measured flow rate is liters per minute (L/min). 2. Daily operating hours are the operating hours of the emission facility during the 30 days of operation prior to measurement .