Annex 3 — 물환경보전법 시행령
284747 · 2026-03-24
■ Enforcement Decree of the Water Environment Preservation Act [Appendix 3] <Amended Dec. 30, 2025>
Warning Levels by Type of Water Pollution Warning and Criteria for Issuance and Lifting of Warnings by Level (Article 28, Paragraph 3
related)
1. Algal Bloom Alert
A. Water Source Section
┌────┬──────────────────────────────────┐
│AlarmLevel│Criteria for Issuance/Removal │
├────┼──────────────────────────────────┤
│Interest │If the cyanobacteria cell count is 1,000 cells/mL or more for two consecutive times │
├────┼──────────────────────────────────┤
│Boundary │If any of the following apply 2 consecutive times │
│ │ 1) When the cyanobacteria cell count is 10,000 cells/mL or more │
│ │ 2) If avian toxins are 10μg/L or higher │
├────┼──────────────────────────────────┤
│Algae │If the cyanobacteria cell count is 1,000,000 cells/mL or more for two consecutive times │
│occurrence │ │
├────┼──────────────────────────────────┤
│Release │If the cyanobacteria cell count is less than 1,000 cells/mL for two consecutive times │
└────┴──────────────────────────────────┘
B. Hydrophilic Activity Section
┌─────┬─────────────────────────────────┐
│AlarmLevel │Criteria for Issuance/Removal │
├─────┼─────────────────────────────────┤
│Interest │If the cyanobacteria cell count is 20,000 cells/mL or higher for two consecutive times │
├─────┼─────────────────────────────────┤
│boundary │If any of the following apply 2 consecutive times │
│ │ 1) When the cyanobacteria cell count is 100,000 cells/mL or more │
│ │ 2) If avian toxins are 20μg/L or higher │
├─────┼─────────────────────────────────┤
│Release │If the cyanobacteria cell count is less than 20,000 cells/mL for 2 consecutive times │
└─────┴─────────────────────────────────┘
Remarks
1. Simultaneous issuance of two or more criteria for measured cyanobacteria cell counts or algal toxins
If the conditions for START are met, the highest level of alarm among them is issued.
2. Even if the criteria for issuance and cancellation under subparagraphs (a) and (b) above are reached, the issuing authority shall...
An algal bloom warning may not be issued or lifted depending on weather conditions, such as forecasts.
3. The number of cyanobacteria cells is Microcystis, Anabaena,
Aphanizomenon and Oscillatoria cells
refers to the sum of numbers.
4. Algal toxins are microcystin-LR, -YR, -RR, -LA, -LY, -
LF.
2. Water Quality Pollution Monitoring and Warning
┌──────┬────────────────────────────────┐
│AlarmLevel │Criteria for Issuance/Removal │
├──────┼────────────────────────────────┤
│Interest │a. Hydrogen ion concentration, dissolved oxygen, total nitrogen, total phosphorus, electrical conductivity, total organic │
│ │Carbon, Volatile Organic Compounds, Phenol, Heavy Metals (Copper, Lead, Zinc, Cadmium │
│ │When two or more items among the items (etc.) exceed the alarm criteria for each measurement item │
│ │U │
│ │a. When biological surveillance measurements persist at the biological surveillance alarm threshold concentration for 30 minutes or more │
│ │systematically │
├──────┼────────────────────────────────┤
│Caution │a. Hydrogen ion concentration, dissolved oxygen, total nitrogen, total phosphorus, electrical conductivity, total organic │
│ │Carbon, Volatile Organic Compounds, Phenol, Heavy Metals (Copper, Lead, Zinc, Cadmium │
│ │Two or more items among the items (etc.) exceed the alarm standard for each measurement item by more than double. │
│ │(In the case of the hydrogen ion concentration item, it refers to 5 or less or 11 or more) │
│ │If exceeding │
│ │a. When biological surveillance measurements persist at the biological surveillance alarm threshold concentration for 30 minutes or more │
│ │and hydrogen ion concentration, total organic carbon, volatile organic compounds, │
│ │among phenol and heavy metals (copper, lead, zinc, cadmium, etc.) items │
│ │When the item exceeds the alarm criteria for each measurement category, and electrical conductivity, total quality │
│ │One or more items among phosphorus, total phosphorus, and chlorophyll-a per measurement item │
│ │If the alarm threshold is exceeded by more than twice │
├──────┼────────────────────────────────┤
│Boundary │ Biosurveillance measurements continuously exceed the biosurveillance alarm threshold concentration for more than 30 minutes │
│ │, electrical conductivity, volatile organic compounds, phenol, heavy metals (old │
│ │One or more items among the items (lead, zinc, cadmium, etc.) by measurement item │
│ │If the alarm threshold is exceeded by more than 3 times │
├──────┼────────────────────────────────┤
│Severe │ After the issuance of the alert, the speed of the water pollution accident progression is very rapid and serious │
│ │level in cases where the occurrence of a crisis is certain │
├──────┼────────────────────────────────┤
│Off │ If the measured value for each measurement item drops below the level of interest │
└──────┴────────────────────────────────┘
Remarks: 1. Regarding water quality pollution monitoring and alarms, such as measurement items by monitoring station and alarm standards by measurement item
Matters necessary therefor shall be notified by the Minister of Climate, Energy and Environment.
2. The fact that dissolved oxygen, electrical conductivity, and total organic carbon exceed the alarm criteria
It refers to cases where the state of exceeding the standard persists for 30 minutes or more.
3. If the hydrogen ion concentration item exceeds the alarm standard, it is 5 or less or 11 or
refers to cases where the condition persists for 30 minutes or more.
4. Among biological surveillance equipment, the fact that the Daphnia surveillance equipment exceeds the alarm criteria is...
Refers to cases where it persists for 30 minutes or more in all test groups.