Annex 10 — 사격 및 사격장 안전관리에 관한 법률 시행령

265033 · 2024-09-03

■ Enforcement Decree of the Act on Safety Management of Shooting and Shooting Ranges [Attached Table 10] <Amended Jan. 31, 2012> Standards for Structure and Facilities of Corridor-Type Air Gun Shooting Ranges (Related to Article 2, Paragraph 2) ┏━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Section │Structure·Facilities ┃ ┠────┼───────────────────────────────┨ ┃four seats │1. The line of fire must be clear and straight ┃ ┃ │2. The location of the altar must be clearly marked ┃ ┃ │3. The width and length of the sadae shall each be at least 80 centimeters ┃ ┃ │4. The four platforms shall be horizontal when viewed as a whole ┃ ┠────┼───────────────────────────────┨ ┃Office Building │1. The office building shall consist of the entire structure from the position of the enlisted man to the bullet shield ┃ ┃ │2. The ceilings, side walls, and floors of the office building shall be 1 mil thick up to 3 meters in front of the building. ┃ ┃ │Steel plates exceeding the limiter or materials with a similar degree of ballistic resistance ┃ ┃ │will be made of quality ┃ ┃ │3. Risk of bullets ricocheting from the ceiling, side walls, floor, etc. of the office building ┃ ┃ │part is covered with wood to the extent that it prevents bullets from ricocheting ┃ ┃ │thing ┃ ┃ │4. Equivalent to an office building capable of preventing the danger of projectiles at a firing range ┃ ┃ │If there are special facilities or natural features, Items 1 through 3 ┃ ┃ │Notwithstanding the provisions of START, it may be structured as determined by the Chief of the Police Station. ┃ ┃ │In this case, the structure is of the same degree as the standards in subparagraphs 1 through 3. ┃ ┃ │Must have an effect. ┃ ┠────┼───────────────────────────────┨ ┃Target │1. The distance between the shot and the target shall be at least 7 meters ┃ ┃ │2. The target shall be positioned directly facing the firing platform. ┃ ┃ │3. The target frame shall be designed so that there is no risk of the bullet ricocheting ┃ ┠────┼───────────────────────────────┨ ┃Ammo catcher│1. There shall be a bullet catcher behind the target ┃ ┃ │2. The projectile concentration part of the bullet catcher shall be at least 2 millimeters thick, and other ┃ ┃ │section is made of steel plate with a thickness of 1 millimeter or more or an equivalent internal ┃ ┃ │Must be made of an elastic material ┃ ┃ │3. The bullet catcher shall be in contact with the ceiling and side walls of the office building ┃ ┃ │4. Equivalent to a bullet catcher capable of preventing the danger of fired bullets at a shooting range ┃ ┃ │If there are special facilities or natural features, Nos. 1 through 3 ┃ ┃ │, it may be structured as determined by the Chief of the Police Station ┃ ┃ │. In this case, the structure is the same as the standards in subparagraphs 1 through 3. ┃ ┃ │must have an effect. ┃ ┠────┼───────────────────────────────┨ ┃Lighting Equipment│1. There shall be lighting equipment ┃ ┃ │2. Lighting equipment shall be located in a position where there is no risk of damage by bullets ┃ ┃ │It ┃ ┠────┼───────────────────────────────┨ ┃Other │1. There must be a place to clean the gun ┃ ┃Matters │2. The spectator seats shall be located behind the seats ┃ ┗━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛