Annex 10 — 사격 및 사격장 안전관리에 관한 법률 시행령
265033 · 2024-09-03
■ Enforcement Decree of the Act on Safety Management of Shooting and Shooting Ranges [Attached Table 10] <Amended Jan. 31, 2012>
Standards for Structure and Facilities of Corridor-Type Air Gun Shooting Ranges (Related to Article 2, Paragraph 2)
┏━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Section │Structure·Facilities ┃
┠────┼───────────────────────────────┨
┃four seats │1. The line of fire must be clear and straight ┃
┃ │2. The location of the altar must be clearly marked ┃
┃ │3. The width and length of the sadae shall each be at least 80 centimeters ┃
┃ │4. The four platforms shall be horizontal when viewed as a whole ┃
┠────┼───────────────────────────────┨
┃Office Building │1. The office building shall consist of the entire structure from the position of the enlisted man to the bullet shield ┃
┃ │2. The ceilings, side walls, and floors of the office building shall be 1 mil thick up to 3 meters in front of the building. ┃
┃ │Steel plates exceeding the limiter or materials with a similar degree of ballistic resistance ┃
┃ │will be made of quality ┃
┃ │3. Risk of bullets ricocheting from the ceiling, side walls, floor, etc. of the office building ┃
┃ │part is covered with wood to the extent that it prevents bullets from ricocheting ┃
┃ │thing ┃
┃ │4. Equivalent to an office building capable of preventing the danger of projectiles at a firing range ┃
┃ │If there are special facilities or natural features, Items 1 through 3 ┃
┃ │Notwithstanding the provisions of START, it may be structured as determined by the Chief of the Police Station. ┃
┃ │In this case, the structure is of the same degree as the standards in subparagraphs 1 through 3. ┃
┃ │Must have an effect. ┃
┠────┼───────────────────────────────┨
┃Target │1. The distance between the shot and the target shall be at least 7 meters ┃
┃ │2. The target shall be positioned directly facing the firing platform. ┃
┃ │3. The target frame shall be designed so that there is no risk of the bullet ricocheting ┃
┠────┼───────────────────────────────┨
┃Ammo catcher│1. There shall be a bullet catcher behind the target ┃
┃ │2. The projectile concentration part of the bullet catcher shall be at least 2 millimeters thick, and other ┃
┃ │section is made of steel plate with a thickness of 1 millimeter or more or an equivalent internal ┃
┃ │Must be made of an elastic material ┃
┃ │3. The bullet catcher shall be in contact with the ceiling and side walls of the office building ┃
┃ │4. Equivalent to a bullet catcher capable of preventing the danger of fired bullets at a shooting range ┃
┃ │If there are special facilities or natural features, Nos. 1 through 3 ┃
┃ │, it may be structured as determined by the Chief of the Police Station ┃
┃ │. In this case, the structure is the same as the standards in subparagraphs 1 through 3. ┃
┃ │must have an effect. ┃
┠────┼───────────────────────────────┨
┃Lighting Equipment│1. There shall be lighting equipment ┃
┃ │2. Lighting equipment shall be located in a position where there is no risk of damage by bullets ┃
┃ │It ┃
┠────┼───────────────────────────────┨
┃Other │1. There must be a place to clean the gun ┃
┃Matters │2. The spectator seats shall be located behind the seats ┃
┗━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛