Standards for Structure and Facilities of Indoor Pistol Shooting Ranges (Related to Article 2, Paragraph 2)
┏━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Section │Structure·Facilities ┃
┠─────┼────────────────────────────────┨
┃four seats │ 1. The line of fire must be clear and straight when viewed as a whole ┃
┃ │ 2. The width and length of the sadae shall each be at least 1.2 meters ┃
┃ │ 3. The position of the altar shall be clearly marked and horizontal when viewed as a whole ┃
┠─────┼────────────────────────────────┨
┃Firing room │ 1. The ceiling, side walls, and floor shall be two within 10 meters of the firing position in the direction of fire ┃
┃Internal │Steel plate of 6 millimeters or more or with a similar degree of ballistic resistance ┃
┃ │shall be made of the same material, and otherwise, steel plate with a thickness of 5 millimeters or more or the same ┃
┃ │shall be made of a material having a certain degree of ballistic resistance ┃
┃ │ 2. In areas such as ceilings, side walls, and floors where there is a risk of bullets ricocheting, two ┃
┃ │Cover the area with wood at least 7 centimeters thick, and the wood is [related to] "Firefighting Facility Installation ┃
┃ │Article 12 of the Act on Maintenance and Safety Management and the Enforcement Decree of the same Act ┃
┃ │Must comply with the flame retardant performance standards pursuant to Article 20 ┃
┃ │ 3. The floor must contain explosives up to a minimum of 2 meters in the direction of firing from the firing position ┃
┃ │Install a base capable of collecting sediment so that water thicker than 1 centimeter... ┃
┃ │Ensure that the gunpowder does not seep into the remaining parts and that the water is not seeped in. ┃
┃ │Cover with flame-retardant material that is easy to burn and poses no risk of bullet ricochet. ┃
┃ │ 4. There will be no windows within the four seasons ┃
┃ │ 5. Soundproofing facilities shall be installed to prevent gunshots from escaping to the outside, but the soundproofing facilities ┃
┃ │and ┃
┃ │It shall comply with the flame retardant performance standards pursuant to Article 20 of the Enforcement Decree of the same Act. ┃
┠─────┼────────────────────────────────┨
┃target and │ 1. The distance between the firing line and the target shall be between 15 meters and 50 meters. ┃
┃Distance │ 2. The target shall be positioned directly facing the firing platform ┃
┃ │ 3. The target frame shall be designed so as not to pose a risk of bullet ricochet ┃
┠─────┼────────────────────────────────┨
┃Ammo catcher │ 1. Behind the target, a ballistic-resistant steel plate at least 10 millimeters thick ┃
┃ │material, and between the target and the bullet catcher, a thickness of 5 ┃
┃ │Bullet ricocheting, such as stretching a flame-retardant rubber plate of millimeters or more ┃
┃ │을 방지할 수 있는 조치를 할 것 ┃
┃ │ 2. The height of the bullet catcher shall reach from the floor to the ceiling ┃
┠─────┼────────────────────────────────┨
┃Lighting and │ 1. Shooting ranges used at night are equipped with lighting facilities sufficient for aiming ┃
┃ElectricalEquipment │will be ┃
┃ │ 2. Lighting equipment shall be located in a position where there is no risk of damage by bullets ┃
┃ │ 3. Electrical equipment such as motors and lighting switches for target operation are unavoidable ┃
┃ │Do not install inside the firing range except where there is a reason ┃
┠─────┼────────────────────────────────┨
┃FirefightingFacility │[Notice] pursuant to Article 9, Paragraph 1 of the "Special Act on Safety Management of Multi-Use Facilities" ┃
┃etc │Be equipped with exhibition facilities, etc. ┃
┠─────┼────────────────────────────────┨
┃Other │1. There must be a place to clean the gun ┃
┃Matters │2. If installing spectator seating, place it behind the four seats ┃
┗━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
Remark: In this table, flame-retardant rubber refers to flame-retardant rubber pursuant to Article 2, Subparagraph 9 of the Enforcement Decree of the Building Act
refers to materials corresponding to non-combustible materials.