■ Enforcement Decree of the Act on Safety Management of Shooting and Shooting Ranges [Appendix 5] <Amended Dec. 31, 2020>
Standards for Structure and Facilities of Rifle Natural Shooting Ranges (Related to Article 2, Paragraph 2)
┏━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Category │Structure·Facilities ┃
┠────────┼─────────────────────────────┨
┃four seats │ 1. The line of fire must be clear and straight when viewed as a whole ┃
┃ │ 2. The sadae shall be at least 1.2 meters wide and at least 2 meters long ┃
┃ │ 3. The location of the altar must be clearly indicated and viewed overall ┃
┃ │Must be horizontal ┃
┠────────┼─────────────────────────────┨
┃Distance to Target │ The distance between the firing line and the target shall be between 25 meters and 300 meters. ┃
┠────────┼─────────────────────────────┨
┃Ground to target │ On the ground between the firing line and the target, there is an object that will make the bullet ricochet ┃
┃ │There won't be ┃
┠────────┼─────────────────────────────┨
┃Target │ 1. The target shall be positioned directly facing the firing platform. ┃
┃ │ 2. The target frame must be made of wood and parts susceptible to being hit by bullets ┃
┃ │No metals shall be exposed during the START portion. ┃
┠────────┼─────────────────────────────┨
┃marker │ 1. To be hit by a bullet in the spotting trench installed for the target operator ┃
┃ │parts of concern with a thickness of 3 meters or more (1 meter or more) ┃
┃ │It shall consist of a soil layer ┃
┃ │ 2. The inspection number shall have the same structure as Attached 9 of Table 4. ┃
┠────────┼─────────────────────────────┨
┃Around a moving target │ The surroundings of a moving target and its target frame vehicle, etc., must be at least 3 meters thick. ┃
┃Facility │It shall be a soil layer of (1 meter or more) ┃
┠────────┼─────────────────────────────┨
┃Ammo catcher │There shall be a bullet catcher made of soil ┃
┠────────┼─────────────────────────────┨
┃OwnedLand │ 1. A site including a hazardous area within the scope separately indicated ┃
┃ │to be effective ┃
┃ │ 2. Frontline in the danger zone where projectiles frequently pass ┃
┃ │There shall be no temporary structures such as START ┃
┃ │ 3. Special facilities or natural ┃
┃ │In cases where there are structures, notwithstanding the criteria of Subparagraph 1, the ┃
┃ │It may be designated as a danger zone by the Commissioner of the Provincial Police Agency. ┃
┃ │, the hazardous area shall have an effect equivalent to the standard of subparagraph 1 ┃
┃ │MTQ2b62051e8ef4028b00812must have START. ┃
┠────────┼─────────────────────────────┨
┃Lighting Equipment │ 1. Shooting ranges used at night shall be equipped with lighting facilities ┃
┃ │ 2. Lighting equipment is located in a position where there is no risk of damage by bullets ┃
┃ │MTQ2b62051e8ef4028b00816will be in START ┃
┠────────┼─────────────────────────────┨
┃Other Matters │ 1. Install boundary fences, boundary walls, etc. around the shooting range ┃
┃ │Put hazard signs ┃
┃ │ 2. There must be a place to clean the gun ┃
┃ │ 3. The spectator seats shall be located behind the seats ┃
┗━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
Remarks: ( ) is for those using only .22 caliber peripheral impact rifles
Apply to the START unit.
[Separate from Appendix 5]
Plan
┏━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃A │Center of the anterior bone line of the saddle ┃
┠─────┼────────────────────────────┨
┃B │Center of the target ┃
┠─────┼────────────────────────────┨
┃AB │Maximum range of the live ammunition being fired ┃
┠─────┼────────────────────────────┨
┃AD │AC ┃
┠─────┼────────────────────────────┨
┃EF │MTQ2b62051e8ef4028b00836A bow-shaped frame centered at START and with AD as the radius ┃
┠─────┼────────────────────────────┨
┃Debt AEF │Danger Zone ┃
┠─────┴────────────────────────────┨
┃ The danger zone of the firing range is the danger zone of each shooting line as indicated in the figure. ┃
┃It shall be a zone encompassing the entire area. ┃
┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛