Annex 5 — 사격 및 사격장 안전관리에 관한 법률 시행령

265033 · 2024-09-03

■ Enforcement Decree of the Act on Safety Management of Shooting and Shooting Ranges [Appendix 5] <Amended Dec. 31, 2020> Standards for Structure and Facilities of Rifle Natural Shooting Ranges (Related to Article 2, Paragraph 2) ┏━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Category │Structure·Facilities ┃ ┠────────┼─────────────────────────────┨ ┃four seats │ 1. The line of fire must be clear and straight when viewed as a whole ┃ ┃ │ 2. The sadae shall be at least 1.2 meters wide and at least 2 meters long ┃ ┃ │ 3. The location of the altar must be clearly indicated and viewed overall ┃ ┃ │Must be horizontal ┃ ┠────────┼─────────────────────────────┨ ┃Distance to Target │ The distance between the firing line and the target shall be between 25 meters and 300 meters. ┃ ┠────────┼─────────────────────────────┨ ┃Ground to target │ On the ground between the firing line and the target, there is an object that will make the bullet ricochet ┃ ┃ │There won't be ┃ ┠────────┼─────────────────────────────┨ ┃Target │ 1. The target shall be positioned directly facing the firing platform. ┃ ┃ │ 2. The target frame must be made of wood and parts susceptible to being hit by bullets ┃ ┃ │No metals shall be exposed during the START portion. ┃ ┠────────┼─────────────────────────────┨ ┃marker │ 1. To be hit by a bullet in the spotting trench installed for the target operator ┃ ┃ │parts of concern with a thickness of 3 meters or more (1 meter or more) ┃ ┃ │It shall consist of a soil layer ┃ ┃ │ 2. The inspection number shall have the same structure as Attached 9 of Table 4. ┃ ┠────────┼─────────────────────────────┨ ┃Around a moving target │ The surroundings of a moving target and its target frame vehicle, etc., must be at least 3 meters thick. ┃ ┃Facility │It shall be a soil layer of (1 meter or more) ┃ ┠────────┼─────────────────────────────┨ ┃Ammo catcher │There shall be a bullet catcher made of soil ┃ ┠────────┼─────────────────────────────┨ ┃OwnedLand │ 1. A site including a hazardous area within the scope separately indicated ┃ ┃ │to be effective ┃ ┃ │ 2. Frontline in the danger zone where projectiles frequently pass ┃ ┃ │There shall be no temporary structures such as START ┃ ┃ │ 3. Special facilities or natural ┃ ┃ │In cases where there are structures, notwithstanding the criteria of Subparagraph 1, the ┃ ┃ │It may be designated as a danger zone by the Commissioner of the Provincial Police Agency. ┃ ┃ │, the hazardous area shall have an effect equivalent to the standard of subparagraph 1 ┃ ┃ │MTQ2b62051e8ef4028b00812must have START. ┃ ┠────────┼─────────────────────────────┨ ┃Lighting Equipment │ 1. Shooting ranges used at night shall be equipped with lighting facilities ┃ ┃ │ 2. Lighting equipment is located in a position where there is no risk of damage by bullets ┃ ┃ │MTQ2b62051e8ef4028b00816will be in START ┃ ┠────────┼─────────────────────────────┨ ┃Other Matters │ 1. Install boundary fences, boundary walls, etc. around the shooting range ┃ ┃ │Put hazard signs ┃ ┃ │ 2. There must be a place to clean the gun ┃ ┃ │ 3. The spectator seats shall be located behind the seats ┃ ┗━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛ Remarks: ( ) is for those using only .22 caliber peripheral impact rifles Apply to the START unit. [Separate from Appendix 5] Plan ┏━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃A │Center of the anterior bone line of the saddle ┃ ┠─────┼────────────────────────────┨ ┃B │Center of the target ┃ ┠─────┼────────────────────────────┨ ┃AB │Maximum range of the live ammunition being fired ┃ ┠─────┼────────────────────────────┨ ┃AD │AC ┃ ┠─────┼────────────────────────────┨ ┃EF │MTQ2b62051e8ef4028b00836A bow-shaped frame centered at START and with AD as the radius ┃ ┠─────┼────────────────────────────┨ ┃Debt AEF │Danger Zone ┃ ┠─────┴────────────────────────────┨ ┃ The danger zone of the firing range is the danger zone of each shooting line as indicated in the figure. ┃ ┃It shall be a zone encompassing the entire area. ┃ ┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛