Annex 4 — 사격 및 사격장 안전관리에 관한 법률 시행령
265033 · 2024-09-03
■ Enforcement Decree of the Act on Safety Management of Shooting and Shooting Ranges [Appendix 4] <Amended Jan. 5, 2021>
Standards for Structure and Facilities of Rifle Bulkhead-Type Firing Ranges (Related to Article 2, Paragraph 2)
┏━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Classification │Structure·Facilities ┃
┠────────────┼─────────────────────────┨
┃four seats │1. The line of fire must be clear and straight ┃
┃ │2. The saddle shall be at least 1.2 meters wide and 2 meters long ┃
┃ │3. The location of the altar is clearly indicated and when viewed as a whole ┃
┃ │Will be horizontal ┃
┠────────────┼─────────────────────────┨
┃Office Building │1. A structure covering the seat shall be installed ┃
┃ │2. The roof of the office building is horizontal from the line of fire in the direction of fire ┃
┃ │Cover the portion of the seat more than 1 meter away by the distance ┃
┃ │3. The roof in the direction of fire is the height of the end of the face relative to the firing position ┃
┃ │If it is 2.1 meters or more based on the surface of the seat ┃
┃ │, both ends shall be in contact with the side wall ┃
┃ │4. The thickness of the office building canopy shall be 15 millimeters or more (4 millimeters ┃
┃ │or higher) or materials with the same degree of ballistic resistance ┃
┃ │로 되어 있을 것 ┃
┃ │5. In the case where the roof of the office building is steel plate or cement concrete ┃
┃ │, in parts where there is a risk of bullets ricocheting, the thickness ┃
┃ │to be covered with lumber of 10 centimeters or more (3 centimeters or more) ┃
┃ │It ┃
┃ │6. Special equipment or ┃
┃ │If there are natural features, items 1 through 5 ┃
┃ │Notwithstanding the regulations, rescue determined by the Commissioner of the City/Provincial Police Agency ┃
┃ │·Facility may be used. In this case, the structure and facility may be designated as ┃
┃ │An effect equivalent to that of standards 1 through 5 ┃
┃ │must have. ┃
┠───┬────────┼─────────────────────────┨
┃Shooting │Distance to Target │The distance from the firing line to the target is 25 meters or more and 300 meters or less. ┃
┃line and │ │Hail thing ┃
┃Target ├────────┼─────────────────────────┨
┃간 │sidewall and │1. The thickness from both sides of the gun mount to the bullet catcher is 80 cm┃
┃ │Bulletproof wall(Bulletproof wall is │A layer of soil or a thickness of 10 meters or more (30 centimeters or more) ┃
┃ │Close to the diagonal line │Cement concrete of centimeters or more (4 centimeters or more) ┃
┃ │starting from the one in order │Must be made of a wall or reinforced concrete prefabricated wall ┃
┃ │assign a number │2. Risk of bullet ricochet on the ballistic surface of the sidewall ┃
┃ │calls) │It must be a structure without START. ┃
┃ │ │3. Up to the bulletproof wall closest to the position of the dead end ┃
┃ │ │the sidewall is 50 ┃
┃ │ │at a height of more than 1 centimeter ┃
┃ │ │position is ┃
┃ │ │ ┃
┃ │ │ 5 centimeters from the top edge of that bulletproof wall and the bullet ┃
┃ │ │Make the top end of the base higher than the straight line connecting them. ┃
┃ │ │4. From the line of fire toward the direction of fire, fire up to 3.6 meters┃
┃ │ │to prevent the bullet from ricocheting upwards ┃
┃ │ │위한 별도 1에 표시된 것과 같은 제1방탄벽이 있을 ┃
┃ │ │It ┃
┃ │ │5. The first bulletproof wall, as shown in Attached 1, has a building canopy thickness ┃
┃ │ │Must be at least 10 centimeters ┃
┃ │ │6. At a shooting range where the distance from the firing line to the target is 25 meters ┃
┃ │ │, as shown in Separate 2, the second ballistic wall, the third ballistic wall and the fourth ballistic wall ┃
┃ │ │There must be a bullet wall. However, the position of the muzzle when standing and ┃
┃ │ │shooting only by a method of keeping the muzzle position the same ┃
┃ │ │As a shooting range, when there is a second bulletproof wall as shown in Attached 3 ┃
┃ │ │is not so above. ┃
┃ │ │7. The distance from the line of fire to the target exceeds 25 meters ┃
┃ │ │For shooting ranges less than 50 meters, Attached 1 and Attached 2 ┃
┃ │ │In addition to the ballistic wall, there shall be a fifth ballistic wall as shown in 4 separately. ┃
┃ │ │However, as a shooting range exclusively for standing fire, Separate 1 and Separate 3 ┃
┃ │ │, if there is a third bulletproof wall as in separate 5, then ┃
┃ │ │not to do so. ┃
┃ │ │8. At a shooting range where the distance from the firing line to the target is 50 meters ┃
┃ │ │, in addition to Separate 1, Separate 2, and Separate 4, depends on the distance ┃
┃ │ │There shall be the 6th ballistic wall and the 7th ballistic wall as per Attached 6. ┃
┃ │ │However, as a shooting range exclusively for standing fire, Separate 1, Separate 3, Separate ┃
┃ │ │also 5 and separate 7, the 4th ballistic wall and the 5th ballistic wall ┃
┃ │ │If present, it shall not be so. ┃
┃ │ │9. The bulletproof wall shall be of the same material and structure as in Separate 8 ┃
┃ │ │10. The bulletproof wall is designed so that both ends are in contact with the side walls ┃
┃ │ │thing ┃
┃ │ │11. Sidewalls or ballistic protection capable of preventing the risk of projectiles ┃
┃ │ │In case there are special facilities or natural features equivalent to a wall ┃
┃ │ │Notwithstanding the provisions of subparagraphs 1 through 10, ┃
┃ │ │It may be made with structures and facilities determined by the Commissioner of the City or Provincial Police Agency. ┃
┃ │ │exists. In this case, the structure and facilities are as specified in subparagraphs 1 through 10 ┃
┃ │ │It must have the same level of effectiveness as the standards up to START. ┃
┃ │ │. ┃
┠───┴────────┼─────────────────────────┨
┃Ground to target │Up to 25 meters from the line of fire toward the direction of fire, thickness ┃
┃ │Composed of fine sand or soil of 20 centimeters or more ┃
┃ │, and for parts exceeding 25 meters, separate 4 to separate 7 ┃
┃ │까지와 같은 구조로 되어 있을 것 ┃
┠───┬────────┼─────────────────────────┨
┃Bullet │Target │1. The target shall be in a position facing the firing platform ┃
┃Receive │ │2. The target frame must be made of wood and be vulnerable to bullet impact ┃
┃and │ │No metals shall be exposed in the START section ┃
┃that │ │3. Target protection frames other than targets installed in close proximity to the bullet catcher ┃
┃Around │ │shall not use metal items such as nails ┃
┃ ├────────┼─────────────────────────┨
┃ │marker │1. Among the targeting trenches installed for the target operator, to the bullet ┃
┃ │ │Parts at risk of impact must be at least 3 meters thick (1 meter ┃
┃ │ │or more) ┃
┃ │ │2. The inspection number shall be in the same structure as Separate 9 ┃
┃ ├────────┼─────────────────────────┨
┃ │on moving target │1. The thickness of surrounding facilities, such as moving targets and their target frames, ┃
┃ │Facilities following │It shall consist of a soil layer of 3 meters or more (1 meter or more) ┃
┃ ├────────┼─────────────────────────┨
┃ │Ammo catcher │1. A soil layer of 3 meters or more (1 meter or more) thick behind the target ┃
┃ │ │으로 된 탄알받이가 있을 것 ┃
┃ │ │2. The surface of the bullet catcher relative to the firing position is a steep slope of 30 degrees or more ┃
┃ │ │로 되어 있을 것 ┃
┃ │ │3. The height of the bullet catcher shall be greater than or equal to the separate standard of 10 ┃
┃ │ │4. A canopy similar to separate 10 is installed on the bullet catcher ┃
┃ │ │을 것 ┃
┃ │ │5. Special equipment capable of preventing the danger of projectiles or ┃
┃ │ │If there are natural features, items 1 through 4 ┃
┃ │ │Notwithstanding the regulations, rescue determined by the Commissioner of the City/Provincial Police Agency ┃
┃ │ │·Facility may be used. In this case, the structure and facility may be designated as ┃
┃ │ │An effect equivalent to the standards of subparagraphs 1 through 4 ┃
┃ │ │must have. ┃
┠───┴────────┼─────────────────────────┨
┃Lighting Equipment │1. Shooting ranges used at night shall be equipped with lighting facilities ┃
┃ │2. Lighting equipment that is not at risk of being damaged by bullets ┃
┃ │will be in ┃
┠────────────┼─────────────────────────┨
┃Other Matters │1. There must be a place to clean the gun ┃
┃ │2. The spectator seats shall be located behind the seats ┃
┗━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━┛
Remarks: ( ) is at the shooting range for firing .22 caliber peripheral impact rifles
Apply.
[Separate 1 of Appendix 4]
Side View (Section)
[Separate 2 of Appendix 4]
Side View (Section)
[Separate 3 of Appendix 4]
Side View (Section)
[Separate 4 of Appendix 4]
Side View (Section)
[Separate 5 of Appendix 4]
Side View (Section)
[Separate 6 of Appendix 4]
Side View (Section)
[Separate 7 of Appendix 4]
Side View (Section)
[Separate 8 of Appendix 4]
Side View (Section)
1. Iron nails or boards (iron nails or beams on the facing surface when attaching steel columns and steel plates
is made dish-shaped)
2. Board
3. Board of a slanted surface using a board for attaching steel plates to the transverse part of a column
Covered timber
4. A(Steel Plate)
5. Joints of steel plates (steel nails) or joints by boards (steel nails or boards on the facing surface
shall be dish-shaped.
6. Joints of steel plates (welding)
7. B(Wood coated on the surface of the steel plate's bevel)
8. Steel Pillar
9. Wood covering the parts of the steel pillar vulnerable to bullet impact
┏━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃A │Thickness 15 cm or more (Attachment 8 Ballistic protection for pistol bulkhead shooting ranges ┃
┃ │The wall is made of steel plate (with a thickness of 0.6 centimeters or more) or similar ┃
┃ │elasticity ┃
┠─┼─────────────────────────────────┨
┃E │Anti-cracking wood ┃
┗━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
[Separate 9 of Appendix 4]
Side view (cross-section)
[Separate 10 of Appendix 4]
Side View (Section)
┏━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃A │Upper limit of ballistics ┃
┠─┼─────────────────────────────────┨
┃B │Upper limit of direct bullet hit ┃
┠─┼─────────────────────────────────┨
┃C │Lower limit of direct hit by a bullet ┃
┠─┼─────────────────────────────────┨
┃BD│BC's length 2/3 ┃
┠─┼─────────────────────────────────┨
┃DE│Plumb line ┃
┠─┼─────────────────────────────────┨
┃F │End part of the beveled surface of the awning (bulletproof roof) ┃
┗━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
1. The ballistic roof shall be at least 3 millimeters thick (Attachment 8: The ballistic roof of a pistol shooting range shall be two
) or a material with a similar degree of ballistic resistance
2. Pillars supporting the roof, etc., shall be constructed in such a way that there is no risk of bullets ricocheting.