Annex 1 — 사격 및 사격장 안전관리에 관한 법률 시행령
265033 · 2024-09-03
■ Enforcement Decree of the Act on Safety Management of Shooting and Shooting Ranges [Appendix 1-2] <Amended Dec. 31, 2020>
Standards for Structure and Facilities of Trap Shooting Ranges (Related to Article 2, Paragraph 2)
┏━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃Classification │Structure·Facilities ┃
┠──────┼────────────────────────────────┨
┃four seats │1. The line of fire shall be clear ┃
┃ │2. The width and length of the sadae are each at least 90 centimeters, and each sadae ┃
┃ │is at least 2 meters ┃
┃ │3. The position of the altar is clearly indicated and, when viewed as a whole, is horizontal ┃
┃ │It ┃
┃ │4. In the case where the firing line is bow-shaped, the middle of both ends and the launcher position ┃
┃ │The angle of connecting the cores shall be 40 degrees or less. ┃
┠──────┼────────────────────────────────┨
┃Emitter │1. The position of the emitter shall be 15 meters forward from the line of fire ┃
┃ │2. The release range of the Clay Pigeon is the center of the turret and the emitter position ┃
┃ │A wire connecting the core (two clay pigeons emitted from one emitter ┃
┃ │or higher, the center of the firing line and the ejection ┃
┃ │and ┃
┃ │Overall, it shall not exceed 45 degrees to the left or right. ┃
┃ │3. When hit by a bullet of the housing equipped for the operator of the emitter ┃
┃ │Parts with a ridge are concrete or earth walls 50 centimeters or thicker ┃
┃ │or made of a material having a similar degree of ballistic resistance ┃
┃ │will be ┃
┃ │4. The upper end of the emitter's cavity is at the same height as the saddle when viewed as a whole ┃
┃ │It ┃
┠──────┼────────────────────────────────┨
┃OwnedLand │1. The site including the hazardous area within the scope indicated in the separate (plan) ┃
┃ │Hold ┃
┃ │2. Special equipment capable of preventing harm caused by projectiles and ┃
┃ │Notwithstanding Subparagraph 1, if there are natural features, the City/Provincial Police may... ┃
┃ │It may be designated as a hazardous area by the Commissioner of the Police Agency. The risk in this case ┃
┃ │The area having an effect equivalent to the standards set forth in subparagraph 1 is ┃
┃ │should. ┃
┃ │3. In parts of the danger zone where projectiles frequently pass, front lines, etc. ┃
┃ │There will be no hypothesis ┃
┠──────┼────────────────────────────────┨
┃Lighting Equipment │1. Shooting ranges used at night shall be equipped with lighting facilities ┃
┃ │2. Lighting equipment shall be located in a position where there is no risk of damage by bullets ┃
┃ │thing ┃
┠──────┼────────────────────────────────┨
┃Other Matters│1. Install boundary fences, boundary walls, etc. around the shooting range and above ┃
┃ │Make a warning sign ┃
┃ │2. There must be a place to clean the gun ┃
┃ │3. The spectator seats shall be located at least 10 meters behind the seats. ┃
┗━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
[Separate from Appendix 1-2 (Plan)]
┏━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃A │ Center of the front end line of the saddle ┃
┠───────┼──────────────────────────┨
┃B │ Location of emitter ┃
┠───────┼──────────────────────────┨
┃BC, BD │ Maximum reach of a clay pigeon on flat terrain (in the figure ┃
┃ │75 meters or more) ┃
┠───────┼──────────────────────────┨
┃AC, AD │ Firing Limit Line (Ballistics when firing at points C and D) ┃
┠───────┼──────────────────────────┨
┃AE, AF │ Maximum range of the fired bullet ┃
┠───────┼──────────────────────────┨
┃bow-shaped EF │ MTQ2b62051e8ef4028b00437A bow-shaped frame centered on STARTA with AF as the radius ┃
┠───────┼──────────────────────────┨
┃Debt-type AEF │ Hazardous Zone ┃
┠───────┴──────────────────────────┨
┃ The danger zone of the firing range is the entire danger zone of each shooting squad as indicated in the figure.┃
┃section. ┃
┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛