Annex 1 — 사격 및 사격장 안전관리에 관한 법률 시행령

265033 · 2024-09-03

■ Enforcement Decree of the Act on Safety Management of Shooting and Shooting Ranges [Appendix 1-2] <Amended Dec. 31, 2020> Standards for Structure and Facilities of Trap Shooting Ranges (Related to Article 2, Paragraph 2) ┏━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃Classification │Structure·Facilities ┃ ┠──────┼────────────────────────────────┨ ┃four seats │1. The line of fire shall be clear ┃ ┃ │2. The width and length of the sadae are each at least 90 centimeters, and each sadae ┃ ┃ │is at least 2 meters ┃ ┃ │3. The position of the altar is clearly indicated and, when viewed as a whole, is horizontal ┃ ┃ │It ┃ ┃ │4. In the case where the firing line is bow-shaped, the middle of both ends and the launcher position ┃ ┃ │The angle of connecting the cores shall be 40 degrees or less. ┃ ┠──────┼────────────────────────────────┨ ┃Emitter │1. The position of the emitter shall be 15 meters forward from the line of fire ┃ ┃ │2. The release range of the Clay Pigeon is the center of the turret and the emitter position ┃ ┃ │A wire connecting the core (two clay pigeons emitted from one emitter ┃ ┃ │or higher, the center of the firing line and the ejection ┃ ┃ │and ┃ ┃ │Overall, it shall not exceed 45 degrees to the left or right. ┃ ┃ │3. When hit by a bullet of the housing equipped for the operator of the emitter ┃ ┃ │Parts with a ridge are concrete or earth walls 50 centimeters or thicker ┃ ┃ │or made of a material having a similar degree of ballistic resistance ┃ ┃ │will be ┃ ┃ │4. The upper end of the emitter's cavity is at the same height as the saddle when viewed as a whole ┃ ┃ │It ┃ ┠──────┼────────────────────────────────┨ ┃OwnedLand │1. The site including the hazardous area within the scope indicated in the separate (plan) ┃ ┃ │Hold ┃ ┃ │2. Special equipment capable of preventing harm caused by projectiles and ┃ ┃ │Notwithstanding Subparagraph 1, if there are natural features, the City/Provincial Police may... ┃ ┃ │It may be designated as a hazardous area by the Commissioner of the Police Agency. The risk in this case ┃ ┃ │The area having an effect equivalent to the standards set forth in subparagraph 1 is ┃ ┃ │should. ┃ ┃ │3. In parts of the danger zone where projectiles frequently pass, front lines, etc. ┃ ┃ │There will be no hypothesis ┃ ┠──────┼────────────────────────────────┨ ┃Lighting Equipment │1. Shooting ranges used at night shall be equipped with lighting facilities ┃ ┃ │2. Lighting equipment shall be located in a position where there is no risk of damage by bullets ┃ ┃ │thing ┃ ┠──────┼────────────────────────────────┨ ┃Other Matters│1. Install boundary fences, boundary walls, etc. around the shooting range and above ┃ ┃ │Make a warning sign ┃ ┃ │2. There must be a place to clean the gun ┃ ┃ │3. The spectator seats shall be located at least 10 meters behind the seats. ┃ ┗━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛ [Separate from Appendix 1-2 (Plan)] ┏━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃A │ Center of the front end line of the saddle ┃ ┠───────┼──────────────────────────┨ ┃B │ Location of emitter ┃ ┠───────┼──────────────────────────┨ ┃BC, BD │ Maximum reach of a clay pigeon on flat terrain (in the figure ┃ ┃ │75 meters or more) ┃ ┠───────┼──────────────────────────┨ ┃AC, AD │ Firing Limit Line (Ballistics when firing at points C and D) ┃ ┠───────┼──────────────────────────┨ ┃AE, AF │ Maximum range of the fired bullet ┃ ┠───────┼──────────────────────────┨ ┃bow-shaped EF │ MTQ2b62051e8ef4028b00437A bow-shaped frame centered on STARTA with AF as the radius ┃ ┠───────┼──────────────────────────┨ ┃Debt-type AEF │ Hazardous Zone ┃ ┠───────┴──────────────────────────┨ ┃ The danger zone of the firing range is the entire danger zone of each shooting squad as indicated in the figure.┃ ┃section. ┃ ┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛