Annex 1 — 도시철도법 시행령

288009 · 2026-07-07

■ Enforcement Decree of the Urban Railway Act [Attached Table 1] Criteria for Calculating Stereochemical Inhibition Rate (Related to Article 10, Paragraph 2, Subparagraph 2) 1. The three-dimensional utilization impairment rate includes the building utilization impairment rate, the underground utilization impairment rate, and the exclusion of the building and underground parts It is calculated by summing the other usage impairment rates. 2. The rate of impairment of use of the building pursuant to subparagraph 1, the rate of impairment of use of the underground portion, excluding the building and the underground portion Other usage impairment rates shall be calculated according to the formulas in each of the following items. a. Building Usage Impairment Rate = α × Usage Rate of Ground Floors with Impaired Usage B. Utilization impairment rate of the underground portion = β × underground layer or underground depth where utilization is impaired Utilization rate . Other usage inhibition rates 1) In cases where other uses of both the above-ground and underground parts are hindered = γ 2) In cases where other use of either the above-ground or underground portion is hindered = γ× V12 or γ× V22 ────── ────── V12+V22 V12+V22 3. α, β, and γ in each item of Subparagraph 2 shall each be calculated according to the following formula. <Distribution Map of Three-Dimensional Land Use> Height │ V11: Building Ground Floor Usage Value ├───┐ V12: Usage value of communication facilities, advertising towers or chimneys, etc. │V12 │ V21: Building basement floor use value or basement use value │ │ V22: Utilization value of groundwater usage facilities or burial of special materials ├───┴┐ Indicator │V11 │ ─┼───┬┴─ │V21 │ ├──┬┘ │V22 │ ├──┘ │ a. Three-dimensional use value (A) = Building ground floor use value (V11) + Building basement floor use value or ground Usage Value (V21)+Other Usage Value (V12+V22) B. Utilization rate (α) based on the use of the building's ground floor = V11 ──── A . Utilization rate (β) based on building basement floor or basement use = V21 ──── A d. Utilization rate (γ) due to other uses = V12+V22 ──────── A E. Three-dimensional land utilization rate: α+β+γ=1 4. The specific calculation standards for the three-dimensional use value and three-dimensional use rate, etc., under each item of Subparagraph 3 are the relevant land Considering the land use status of the city and neighboring land, location conditions, and other regional characteristics, the city/province's... Set as an example.