■ Enforcement Decree of the Air Environment Preservation Act [Table 11-3] <Amended June 23, 2026>
Clean Fuel Usage Standards (Related to Article 43)
1. Scope of Facilities Requiring the Use of Clean Fuels
a. As a multi-unit dwelling pursuant to Article 3-4 of the Enforcement Decree of the Building Act, the same boiler this
for one or more complexes jointly utilizing heat
Heat is supplied via a medium heating system (including district cooling and heating), and within the complex
Multi-unit housing where the average exclusive area of all households exceeds 40.0㎡
B. For district heating and cooling business pursuant to Article 2, Subparagraph 1 of the Enforcement Decree of the Collective Energy Business Act
Facilities. However, among facilities for district heating and cooling business, waste heat from power generation for district heating and cooling
facilities approved by the Minister of Climate, Energy and Environment
is excluded.
. Commercial boilers with a total hourly evaporation rate of 0.2 tons or more (commercial and public
Including common boilers, but excluding industrial boilers)
d. Power generation facilities. However, industrial combined heat and power generation facilities are excluded.
Remarks: 1. Among the facilities under items (a) through (d), the "New and Renewable Energy Development·i
Using new energy and renewable energy pursuant to Article 2 of the "Act on Promotion of Use and Supply"
Facilities are excluded.
2. Matters necessary for approval criteria, procedures, and revocation of approval, etc., pursuant to the proviso of Subparagraph (b)
The Minister of Climate, Energy and Environment shall determine and announce this.
2. Clean Fuel Usage Areas and Target Facilities
A. Target Areas and Facilities for Clean Fuel Use
1) Commercial facilities or power generation facilities
┏━━━━━━━━━━━━━━━━┯━━━━━━━━━━━┯━━━━━━━━━┓
┃Target Region │Sum of boiler capacities │Fuel Type ┃
┠─┬──────────────┼───────────┼─────────┨
┃수│Seoul, Incheon Metropolitan City │· 2 tons or more │Clean Fuel ┃
┃To│Suwon-si, Bucheon-si, Gwacheon-si, Seongnam│·0.2 tons or more and less than 2 tons │Clean fuel or diesel┃
┃Ticket│City, Gwangmyeong City, Anyang City, Uijeongbu │ │ ┃
┃ │City, Ansan City, Uiwang City, Gunpo │ │ ┃
┃ │City, Siheung-si, Guri-si, Goyang-si │ │ ┃
┃ ├──────────────┼───────────┼─────────┨
┃ │Pyeongtaek-si·Osan-si·Yongin-si │·0.2 tons or more │Clean fuel or diesel┃
┠─┼──────────────┼───────────┼─────────┨
┃Part│Busan Metropolitan City, Ulsan Metropolitan City, │·0.2 tons or more │Clean fuel or diesel┃
┃san│Yangsan-si, Changwon-si, Gimhae-si │ │ ┃
┃Ticket│ │ │ ┃
┠─┼──────────────┼───────────┼─────────┨
┃to│Daegu Metropolitan City (excluding Gunwi-gun) │·0.2 tons or more │Clean fuel or diesel┃
┃old│한다), Gumi-si, Pohang-si │ │ ┃
┃Ticket│ │ │ ┃
┠─┼──────────────┼───────────┼─────────┨
┃Before│Jeonnam Gwangju Integrated Special City Dong-gu, │·0.2 tons or more │Clean fuel or diesel┃
┃Nam│Seo-gu, Nam-gu, Buk-gu, Gwangsan-gu, │ │ ┃
┃Ticket│Gwangyang City, Yeosu City (formerly Yeocheon County) │ │ ┃
┃ │Exclude) │ │ ┃
┠─┼──────────────┼───────────┼─────────┨
┃Before│Jeonju-si, Gunsan-si, Iksan-si │·0.2 tons or more │Clean fuel or diesel┃
┃Book│ │ │ ┃
┃Ticket│ │ │ ┃
┠─┼──────────────┼───────────┼─────────┨
┃to│Daejeon Metropolitan City, Cheongju City, Gyeryong City │·0.2 tons or more │Clean fuel or diesel┃
┃Before│ │ │ ┃
┃ticket│ │ │ ┃
┗━┷━━━━━━━━━━━━━━┷━━━━━━━━━━━┷━━━━━━━━━┛
2) Central heating or district heating multi-family housing
┏━━━━━━━━━━━━━┯━━┯━━━━━━━━━━━━━━━━━━┯━━━━━━━┓
┃Target Region │Classification│Exclusive Area │Fuel Type ┃
┠─┬───────────┼──┼──────────────────┼───────┨
┃수│Seoul │- │· 82.6㎡ or more │Clean Fuel ┃
┃To│ │ │ │ ┃
┃ticket│ │ │· Over 40.0㎡ and less than 82.6㎡ │Clean Fuel or ┃
┃ │ │ │ │Via ┃
┃ ├───────────┼──┼──────────────────┼───────┨
┃ │Incheon Metropolitan City, Suwon City, Bu│Existing│· 82.6㎡ or more │Clean Fuel ┃
┃ │Cheon-si, Gwacheon-si, Seongnam │ │ │ ┃
┃ │City, Gwangmyeong City, Anyang │ │· Over 59.5㎡ and less than 82.6㎡ │Clean Fuel or ┃
┃ │City, Uijeongbu City, An │ │ │Via ┃
┃ │Sansi, Uiwangsi, ├──┼──────────────────┼───────┨
┃ │Gunpo-si, Siheung-si, Gu │New│· 82.6㎡ or more (Apartments 1991. 1. │Clean Fuel ┃
┃ │RiGoyangCity │ │1. Thereafter, the row house was April 11, 1991. │ ┃
┃ │ │ │After Facility that has received business approval) │ ┃
┃ │ │ │ │ ┃
┃ │ │ │· 46.3㎡ or more and less than 82.6㎡ (Apartments │Clean Fuel or ┃
┃ │ │ │After January 1, 1991, row houses are │Via ┃
┃ │ │ │Business approval after April 11, 1991 │ ┃
┃ │ │ │) │ ┃
┃ │ │ │ │ ┃
┃ │ │ │· Over 40.0㎡ and less than 46.3㎡ (1994. │Clean Fuel or ┃
┃ │ │ │5. 1. Subsequently, the city that received business approval │Via ┃
┃ │ │ │Story) │ ┃
┃ ├───────────┼──┼──────────────────┼───────┨
┃ │Pyeongtaek-si, Osan-si │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃ │Yongin-si │ │ │Via ┃
┃ │ ├──┼──────────────────┼───────┨
┃ │ │New│· Exceeding 40.0㎡ (After Jan. 1, 1997 │Clean Fuel or ┃
┃ │ │ │Facility that has received business approval) │Via ┃
┠─┼───────────┼──┼──────────────────┼───────┨
┃Part│Busan Metropolitan City │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃san│ │ │ │Via ┃
┃Ticket│ ├──┼──────────────────┼───────┨
┃ │ │New│· Exceeding 40.0㎡ (After May 1, 1994 │Clean Fuel or ┃
┃ │ │ │Facility that has received business approval) │Via ┃
┃ ├───────────┼──┼──────────────────┼───────┨
┃ │Ulsan Metropolitan City, Yangsan City, │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃ │Changwon-si, Gimhae-si │ │ │Via ┃
┃ │ ├──┼──────────────────┼───────┨
┃ │ │New│· Exceeding 40.0㎡ (After January 1, 1997 │Clean Fuel or ┃
┃ │ │ │Facilities that have received business approval. However, Gimhae │Via ┃
┃ │ │ │The city approved business plans after July 1, 1998. │ ┃
┃ │ │ │Applies only to facilities that have received) │ ┃
┠─┼───────────┼──┼──────────────────┼───────┨
┃to│Daegu Metropolitan City(Gunwi-gun │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃old│is excluded) │ │ │Via ┃
┃Ticket│ ├──┼──────────────────┼───────┨
┃ │ │New│· Exceeding 40.0㎡ (After May 1, 1994 │Clean Fuel or ┃
┃ │ │ │Facility that has received business approval) │Via ┃
┃ ├───────────┼──┼──────────────────┼───────┨
┃ │Gumi-si, Pohang-si │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃ │ │ │ │Via ┃
┃ │ ├──┼──────────────────┼───────┨
┃ │ │New│· Exceeding 40.0㎡ (After Jan. 1, 1997 │Clean Fuel or ┃
┃ │ │ │Facility that has received business approval) │Diesel ┃
┠─┼───────────┼──┼──────────────────┼───────┨
┃Before│Jeonnam-Gwangju Integrated Special │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃nam│City Dong-gu, Seo-gu, Nam │ │ │Via ┃
┃Ticket│District, Buk-gu, Gwangsan-gu, ├──┼──────────────────┼───────┨
┃ │Gwangyang-si, Yeosu-si (formerly │New│· Exceeding 40.0㎡ (After Jan. 1, 1997 │Clean Fuel or ┃
┃ │Yeocheongun-eun-myeon │ │Facility that has received business approval) │Via ┃
┃ │Exclude) │ │ │ ┃
┠─┼───────────┼──┼──────────────────┼───────┨
┃Before│Jeonju-si, Gunsan-si, │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃Book│IksanCity │ │ │Via ┃
┃Ticket│ ├──┼──────────────────┼───────┨
┃ │ │New│· Exceeding 40.0㎡ (After Jan. 1, 1997 │Clean Fuel or ┃
┃ │ │ │Facility that has received business approval) │Via ┃
┠─┼───────────┼──┼──────────────────┼───────┨
┃to│Daejeon Metropolitan City, │Existing│· 59.5㎡ or more │Clean Fuel or ┃
┃Before│Cheongju-si, Gyeryong-si │ │ │Via ┃
┃Ticket│ ├──┼──────────────────┼───────┨
┃ │ │New│· Exceeding 40.0㎡ (After Jan. 1, 1997 │Clean Fuel or ┃
┃ │ │ │Facility that has received business approval) │Via ┃
┗━┷━━━━━━━━━━━┷━━┷━━━━━━━━━━━━━━━━━━┷━━━━━━━┛
Remark: 1. Island areas where the supply of clean fuel is impossible are excluded from areas eligible for clean fuel use
.
2. As a facility required to use only clean fuel, until the start date of clean fuel use
If a clean fuel supply pipe is not installed, the installation of the clean fuel supply pipe
value is completed and clean fuel can be supplied, diesel
can be used.
B. Heavy oil may be used in the following cases.
1) Subjects required to use clean fuel or diesel from September 1, 1998
Among facilities, those intending to use only clean fuels without using diesel
As a theory, prior to January 1, 1997 (in the case of Gimhae City, prior to June 30, 1998)
and the structure uses only heavy oil
is recorded, and even after the start date of clean fuel use, the boiler's service life (10 years)
For facilities where the START process has not been completed and the City/Provincial Governor has approved the use of heavy oil,
U
2) Among the regions under Item (a), former counties incorporated into city areas with a mixed urban-rural form
In the region prior to January 1, 1997 (in the case of Gimhae City, June 30, 1998)
), the competent mayor or provincial governor [regarding] the city gas supply pipes in the relevant area
until the boiler's service life ends
If installation is determined to be impossible
. In the case of intending to continue using heavy oil in accordance with subparagraph 1), the clean fuel
A document proving the initial installation date of the boiler no later than 4 months prior to the commencement date
An application for approval to use heavy oil must be submitted to the competent Mayor or Provincial Governor by attaching the following documents.
d. In cases where the Mayor or Provincial Governor receives an application for approval of the use of heavy oil pursuant to subparagraph c, the relevant city
Initial installation date of the facility, service life of the boiler, and city gas supply pipe installation plan, etc.
to ensure that the city gas supply pipe is sufficient before the boiler's service life ends
In cases where it is determined that installation is possible even after the start date of use of clean fuel,
Approval to use heavy oil until the end of the remaining useful life of the tiller
can be done, and from the end of the useful life, only clean fuel must be used
.
e. In accordance with subparagraph 2), the competent mayor or provincial governor regarding the boiler's useful life for the relevant facility
When heavy oil is used up to the START date, from the date the boiler's service life ends,
Must use only diesel fuel.
3. The Minister of Climate, Energy and Environment [may] power generation facilities within areas required to use clean fuels
In any of the following cases, fuel other than clean fuel may be used
can record.
a. If operation commenced prior to December 21, 1996, or if fuel other than clean fuel was purchased
for use in the power generation of a thermal power plant that has received a business permit or environmental impact assessment consultation
Facility
B. Thermal power generation recognized by the Minister of Climate, Energy and Environment for reasons related to energy and power supply and demand
Power generation facility of a cow
. Even if the power generation facilities of a thermal power plant are expanded, the already permitted air pollutant emission
. However, 2001
Power plants that commenced operation prior to December 29 of the START year are excluded.
. Compared to when using clean fuel (or when using diesel for facilities subject to the use of clean fuel or diesel),
In the case of low pollutant emissions
E. Instantaneous increase in electricity demand at power plants using clean fuels or city gas
Submit relevant data to the Minister of Climate, Energy and Environment for approval due to reasons such as a surge in demand.
If approval has been received. However, if the instantaneous power demand growth rate is within 15%, approval is received
Diesel or low-sulfur high-pitch-point fuel oil may be used without .
4. When supplying district energy that can use low-sulfur, high-paste fuel oil in addition to clean fuels
Section
a. Waste heat or waste from LNG combined cycle power plants in the metropolitan area pursuant to Subparagraph 2, Item a, Subparagraph 2)
Utilizing waste heat from waste incineration facilities individually or simultaneously for collective energy supply targets
District energy supplying more than 85% of the total heating requirements in the region
SupplyFacility
b. In the Seoul Metropolitan Area pursuant to Subparagraph 2, Item (a) 2), prior to June 27, 1998, collective energy
Among the facilities that have received permission for the supply business, the Minister of Climate, Energy and Environment [referring to] low-sulfur, high-fluidity [unclear text]
District energy supply facility authorized to use point fuel oil
. In areas incorporated into a consolidated city or newly included as clean fuel usage target areas
Low-sulfur, high-paste fuel oil or BC oil (only if sulfur oxide removal facilities are installed
) and on December 21, 1996
District energy supply facilities that received a district energy supply business license prior to the START date
Remark: Among district energy supply facilities capable of using low-sulfur, high-paste fuel oil
Expanded heat supply facilities by amending the business license after December 21, 1996
If you intend to do so, you must use clean fuel.
5. City gas business operators regarding the city gas facilities subject to the use of clean fuels for the relevant year
Submit the plan for the installation of water supply pipes to the Mayor/Provincial Governor by January 31 of the relevant year.
must be done, and when the city gas supply pipe has been installed and completed in accordance with the said installation plan
must notify the relevant City/Provincial Governor within 15 days from the date of completion of installation
.
6. District Heating Usage
a. A district energy supply target area announced pursuant to Article 5 of the District Energy Business Act
In the region, a district heating supplier (referring to Korea District Heating Corporation, etc.; hereinafter the same)
When finalizing a district heating supply plan or when the head of a local government [determines] general waste incineration
has been finalized and announced
Facilities subject to the use of clean fuel under Subparagraph 2 select clean fuel or district heating
Use it, but diesel may be used until district heating is supplied.
b. The district heating supplier referred to in subparagraph a shall, regarding the district heating target facilities for the relevant year
Submit the district heating supply pipe installation plan to the Mayor/Provincial Governor by January 31 of the relevant year.
must be submitted, and when the district heating supply pipes are completed in accordance with the said installation plan
In such cases, report to the relevant City/Provincial Governor within 15 days from the date of completion of installation.
Must notify.
7. Sealing measures for dual-purpose burners
a. The Mayor/Do Governor or the head of a local environmental agency shall use only clean fuels in accordance with Subparagraph 2
In target facilities designed to allow the simultaneous use of clean fuels and fuel oils,
, in the case where a dual-purpose burner is installed, seal the fuel oil supply pipe
must.
b. The installer or operator of a combined burner sealed in accordance with subparagraph a, due to the interruption of the supply of clean fuel, etc.
When intending to use fuel oil, [you must] consult the competent city/provincial governor or local government in advance.
You must notify the head of the environmental agency and obtain the unsealing from the relevant public official.
However, due to the occurrence of unforeseen situations such as the disruption of clean fuel supply, it is unavoidable.
In cases where it is approved, first remove the seal and use it, but immediately contact the competent City/Provincial Governor
or the head of the regional environmental agency must be notified.