Annex 5 — 대기환경보전법 시행령
287111 · 2026-07-01
■ Enforcement Decree of the Air Environment Preservation Act [Table 5] <Amended Dec. 31, 2018> [Effective Date: Jan. 1, 2020] Nitrogen Oxide Related Section
Method for Calculating Daily Excess Discharge and Daily Flow Rate (Related to Article 25, Paragraph 3)
1. Method for Calculating Daily Excess Emissions
┌────┬─────┬──────────────────────────────────────┐
│Classification │Pollution │CalculationMethod │
├────┼─────┼──────────────────────────────────────┤
│General Contamination│Sulfur Oxides │Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 6⁴ ÷ 22.4 │
│Substance │dust │Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ │
│ │Nitrogen Oxides│Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 46 ÷ 22.4 │
│ │Ammonia │Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 17 ÷ 22.4 │
│ │Hydrogen Sulfide │Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 3⁴ ÷ 22.4 │
│ │Carbon disulfide│Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 76 ÷ 22.4 │
├────┼─────┼──────────────────────────────────────┤
│SpecificWaiting│Fluoride │Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 19 ÷ 22.4 │
│Hazardous Substance│Hydrogen Chloride │Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 36.5 ÷ 22 │
│ │Hydrogen Cyanide│.4 │
│ │ │Daily flow × Concentration exceeding permissible discharge limit × 10⁻⁶ × 27 ÷ 22.4 │
└────┴─────┴──────────────────────────────────────┘
Remarks
1. Concentration exceeding permissible emission limit = Emission concentration - Permissible emission limit concentration
2. Daily pollutant emissions exceeding permissible emission standards for specific hazardous air pollutants, decimal places
Calculate to the fourth decimal place, and for general pollutants, calculate to the first decimal place
.
3. The unit of dust emission concentration is cubic meters at standard conditions (referring to 0℃ and 1 atmosphere).
(mg/S㎥), and the unit of emission concentration for other pollutants shall be ppm
(ppm).
2. Method for Calculating Daily Flow Rate
┌──────────────────┐
│Daily flow rate = Measured flow rate × Daily operating hours │
└──────────────────┘
Remarks
1. The unit of the measured flow rate shall be cubic meters per hour (㎥/h).
2. Daily operating hours refer to the emission facility during the 30 days of operation prior to measuring emissions
Displays the average operating time in hours.