Annex 3 — 대기환경보전법 시행령

287111 · 2026-07-01

■ Enforcement Decree of the Air Environment Preservation Act [Table 3-3] <Amended Dec. 23, 2025> Standards for Facilities, Equipment, and Technical Personnel of Measuring Instrument Management Agency Business (Related to Article 19-3, Paragraph 1) ┌─────┬───────────────────────────────┐ │Category │Based │ ├─────┼───────────────────────────────┤ │1. Facilities and │a. Equip a laboratory │ │Equipment │B. Equip each of the following with equipment │ │ │ 1) The following items are stipulated in Article 6 of the “Act on Testing and Inspection, etc. in the Environmental Field” │ │ │to be measured and analyzed in accordance with the standard environmental pollution testing method pursuant to Paragraph 1 │ │ │or equipment capable of measuring and analyzing the following items │ │ │exhaust gas measuring instrument and its accessories (type approval pursuant to Article 9 of the same Act │ │ │(Applies only to those who have received a signature) │ │ │ a) Sulfur dioxide │ │ │ b) Nitrogen oxides │ │ │ da) Carbon monoxide │ │ │ ra) Oxygen │ │ │ 2) The following items are stipulated in Article 6 of the "Act on Testing and Inspection, etc. in the Environmental Field" │ │ │to be measured and analyzed in accordance with the standard environmental pollution testing method pursuant to Paragraph 1 │ │ │Equipment capable of START │ │ │ a) Dust │ │ │ b) Hydrogen chloride │ │ │ ) Ammonia │ │ │ ra) Hydrogen fluoride │ │ │ 3) Measure the flow velocity or volume and temperature of the exhaust gas exiting the outlet │ │ │Determinable equipment │ ├─────┼───────────────────────────────┤ │2. Technical Manpower│Each of the following technical personnel shall be provided. In this case, institutions, corporations, and organizations │ │ │If the representative or sole proprietor of the entity falls under any of the following technical personnel │ │ │, the representative or sole proprietor is the relevant technical personnel │ │ │tablet. │ │ │a. One or more persons falling under any of the following │ │ │ 1) After obtaining the Air Environment Engineer qualification, work in a related field for at least 2 years │ │ │Person who died │ │ │ 2) After obtaining the Industrial Engineer qualification in Air Environment, 5 years or more in a related field │ │ │Person engaged in the │ │ │ 3) Person who has been engaged in the operation and management of automatic chimney measuring equipment for 10 years or more │ │ │b. One or more persons falling under any of the following │ │ │ 1) Environmental Measurement and Analysis Specialist in the Atmospheric Field │ │ │ 2) Water Quality Environment, Air Environment, Waste Treatment, Noise & Vibration, Machining & Assembly │ │ │or a person with a qualification of Industrial Engineer in Mechanical Design or higher │ │ │ 3) After obtaining the Chemical Analysis Technician qualification, have at least 3 years of experience in a related field │ │ │Person engaged │ │ │ 4) Person who has been engaged in the operation and management of automatic chimney measuring equipment for 5 years or more │ │ │. One or more persons falling under any of the following │ │ │ 1) Engineer in the Electrical, Electronics, Information Technology, or Telecommunications fields │ │ │ 2) Industrial Engineer in the Electrical, Electronic, Information Technology, or Telecommunications fields │ │ │Person who has worked in the relevant field for at least 3 years after obtaining a qualification of │ │ │AM │ │ │ 3) Person who has been engaged in the operation and management of automatic chimney measuring equipment for at least 3 years │ └─────┴───────────────────────────────┘ Remarks 1. Measurement stand for the atmospheric field pursuant to Article 16 of the Act on Testing and Inspection, etc. in the Environmental Field The business operator and items 1)a) through d) of Subparagraph 1b of the table above, and items 2)a) through d) of the same subparagraph Any one of the items in the START sheet or the flow velocity, flow rate, and temperature items in subparagraph 3) of the same item , the relevant item shall be measured during the contract period It is deemed to be equipped with equipment capable of analysis, and Item 1, Subparagraph (b) 1)a) through (d)k of the table above. , items 2)a) through d) of the same subparagraph, and the flow velocity and flow rate of 3) of the same subparagraph, and In the case where a measurement agency contract has been concluded for all temperature items, during the contract period, the above It is deemed to be equipped with the facilities and equipment specified in Item 1 of the Table. 2. Conclude a joint use agreement or lease agreement regarding the facilities or equipment in Item 1 of the above table was performed, during the contract period, the relevant facility or equipment for the relevant item It shall be deemed that the relevant facilities or equipment have been measured. However, in the case where a lease agreement has been concluded, it shall be deemed that the relevant facilities or equipment have been measured It must be used exclusively for the purpose of managing devices. 3. The qualification under Item 2 of the above table is a national technical qualification pursuant to Article 2, Item 1 of the National Technical Qualifications Act or environmental measurement pursuant to Article 19, Paragraph 1 of the "Act on Testing and Inspection, etc. in the Environmental Field" It shall be based on the Analyst qualification. 4. In cases where one technical personnel holds two or more types of technical qualifications, a Type 1 technician type. 5. Measurement stand for the atmospheric field pursuant to Article 16 of the Act on Testing and Inspection, etc. in the Environmental Field In the case where an operator intends to register for the measuring instrument management agency business, common technical personnel may not be provided in duplicate. 6. The standards under Subparagraph 4) of Item (b) and Subparagraph 3) of Item (c) of Subparagraph 2 of the above table shall apply until December 31, 2021.