Annex 3 — 대기환경보전법 시행령

287111 · 2026-07-01

■ Enforcement Decree of the Air Environment Preservation Act [Table 3] <Amended May 3, 2022> Emission facilities subject to installation of automatic chimney measuring devices, measurement items, installation exemptions, installation timing, and installation grace period (Related to Article 17, Paragraph 5) 1. Emission Facilities Subject to Installation of Automatic Chimney Measuring Instruments and Measurement Items ┏━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━┓ ┃Emission facilities subject to attachment │MeasurementItem ┃ ┠──────────────────────────────┼──────────────┨ ┃a. Coke manufacturing facilities and related product storage facilities │ ┃ ┃ Coke or related product manufacturing facility │Dust, sulfur oxides, nitrogen ┃ ┃ - Emissions excluding sulfur recovery facilities among coke manufacturing facilities │Small Oxide ┃ ┃Classification Exhaust gas volume of 10,000 standard cubic meters or more per hour │ ┃ ┃facility │ ┃ ┠──────────────────────────────┼──────────────┨ ┃B. Petroleum Product Manufacturing Facility │ ┃ ┃ 1) Heating Facility │Dust, Nitrogen Oxides, ┃ ┃ - Facilities with a heating capacity of 25 million kilocalories per hour or more │Sulfur Oxides ┃ ┃ │ ┃ ┃ 2) Catalyst Regeneration Facility │dust ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 3) Sulfur oxide removal facility or sulfur recovery facility │Sulfur Oxides ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 4) Carbon Monoxide Incineration Facility of Heavy Oil Cracking Facility │Dust, sulfur oxides, nitrogen ┃ ┃ - Exhaust gas by outlet excluding sulfuric acid manufacturing or sulfur recovery facilities │Oxides, Carbon Monoxide ┃ ┃Facilities with a capacity of 10,000 standard cubic meters or more per hour │small ┃ ┠──────────────────────────────┼──────────────┨ ┃. Basic organic compound manufacturing facility │ ┃ ┃ 1) Heating Facility │Dust, Nitrogen Oxides, ┃ ┃ - Facilities with a heating capacity of 25 million kilocalories per hour or more │Sulfur Oxides ┃ ┃ │ ┃ ┃ 2) Catalyst Regeneration Facility │dust ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 3) Sulfur oxide removal facility or sulfur recovery facility │Sulfur Oxides ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 4) Carbon Monoxide Incineration Facility of Heavy Oil Cracking Facility │Dust, sulfur oxides, nitrogen ┃ ┃ - Exhaust gas by outlet excluding sulfuric acid manufacturing or sulfur recovery facilities │Oxides, Carbon Monoxide ┃ ┃Facilities with a capacity of 10,000 standard cubic meters or more per hour │small ┃ ┠──────────────────────────────┼──────────────┨ ┃. Basic Inorganic Compound Manufacturing Facility │ ┃ ┃ 1) Sulfuric Acid Manufacturing Facility (Sulfur Combustion, Non-ferrous Metal Smelting, Heavy Oil Cracking Facility) │Sulfur Oxides ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 2) Inorganic acid manufacturing facility excluding sulfuric acid │ ┃ ┃ a) Phosphoric Acid Manufacturing Facility │HydrogenFluoride ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities │ ┃ ┃ │ ┃ ┃ b) Fluorine compound manufacturing facility │HydrogenFluoride ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities with more than [number] │ ┃ ┃ │ ┃ ┃ c) Hydrochloric acid manufacturing facility or hydrogen chloride recovery facility │Hydrogen Chloride ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities with more than │ ┃ ┃ │ ┃ ┃ 3) Phosphate Calcination Facility │Dust, Hydrogen Fluoride, Numbling ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Small Oxide ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 4) Melting/Dissolution Facilities, Calcination Facilities or Heating Facilities │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃E. Manufacturing facilities for inorganic pigments, dyes, and softeners, and when manufacturing other colorants │ ┃ ┃Section │ ┃ ┃ Melting/Dissolution Facility, Calcination Facility or Heating Facility │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃B. Chemical Fertilizer and Nitrogen Compound Manufacturing Facilities │ ┃ ┃ 1) Chemical Fertilizer Manufacturing Facility │ ┃ ┃ a) Manufacturing facility for nitrogenous fertilizers (including urea) │Dust, Ammonia ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities with more than │ ┃ ┃ │ ┃ ┃ b) Compound fertilizer manufacturing facility │Dust, ammonia, fire ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │HwaHyundai ┃ ┃Facilities with more than [number] │ ┃ ┃ │ ┃ ┃ 2) Nitric acid manufacturing facility or nitric acid recovery and regeneration facility │ ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Nitrogen Oxides ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 3) Melting/Dissolution Facilities, Calcination Facilities or Heating Facilities │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃Company. Pharmaceutical Manufacturing Facility │ ┃ ┃ Melting/Dissolution Facility, Calcination Facility or Heating Facility │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities exceeding │ ┃ ┠──────────────────────────────┼──────────────┨ ┃A. Other Chemical Product Manufacturing Facilities │ ┃ ┃ Melting/Dissolution Facility, Calcination Facility or Heating Facility │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃. Chemical fiber manufacturing facility │ ┃ ┃ Melting/Dissolution Facility, Calcination Facility or Heating Facility │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities exceeding │ ┃ ┠──────────────────────────────┼──────────────┨ ┃Vehicle. Rubber and Rubber Product Manufacturing Facility │ ┃ ┃ Melting/Dissolution Facility, Calcination Facility or Heating Facility │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities exceeding │ ┃ ┠──────────────────────────────┼──────────────┨ ┃K. Manufacturing facilities for synthetic rubber, plastic materials and plastic products │ ┃ ┃ Melting/Dissolution Facility, Calcination Facility or Heating Facility │ ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Dust, Nitrogen Oxides, ┃ ┃Facilities above │Sulfur Oxides ┃ ┠──────────────────────────────┼──────────────┨ ┃Ta. Glass and glass product manufacturing facilities [recycling raw material processing facilities │ ┃ ┃Includes] │ ┃ ┃ 1) Melting and dissolution facility for manufacturing glass (including glass fibers) │Dust, Nitrogen Oxides, ┃ ┃ - As a facility other than a pot, the amount of exhaust gas per outlet │Sulfur oxides(clean fuel ┃ ┃Facilities with a capacity of 10,000 standard cubic meters or more per hour │and sulfur content is 0.5 ┃ ┃ │percent ┃ ┃ │When using fuel ┃ ┃ │(Excluding the explanation) ┃ ┃ │ ┃ ┃ 2) Acid treatment facility (continuous type only as a facility using hydrochloric acid and hydrogen chloride │Hydrogen Chloride ┃ ┃corresponding) │ ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃Part. Manufacturing facilities for ceramics and pottery products [Processing of raw materials for recycling │ ┃ ┃Includes facilities] │ ┃ ┃ Sintering facilities and melting/dissolving facilities │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities exceeding │ ┃ ┠──────────────────────────────┼──────────────┨ ┃H. Manufacturing facilities for cement, lime, plaster and their products │ ┃ ┃ 1) Calcination and Cooling Facilities of Cement Manufacturing Facilities │Dust, nitrogen oxides (small ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Applies only to Seong-ro), ┃ ┃Facilities exceeding │Hydrogen chloride(Waste synthetic water ┃ ┃ │Use tributaries as fuel ┃ ┃ │Applicable only to kilns that start ┃ ┃ │) ┃ ┃ │ ┃ ┃ 2) Calcination facility of lime manufacturing facility │Dust, Nitrogen Oxides ┃ ┃ - Exhaust gas volume per outlet is 30,000 standard cubic meters per hour │ ┃ ┃Facilities exceeding │ ┃ ┠──────────────────────────────┼──────────────┨ ┃. Other non-metallic mineral product manufacturing facilities (asphalt product manufacturing facilities are │ ┃ ┃Exclude) │ ┃ ┃ 1) Calcination facilities and melting/dissolving facilities │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 2) Calcination and Drying Facilities of Gypsum Manufacturing Facilities │Dust, Nitrogen Oxides ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃. Asphalt product manufacturing facility │ ┃ ┃ Melting/Dissolution Facility │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃The. Primary metal manufacturing facility │ ┃ ┃ 1) Electric Furnace (Arc Furnace only) │dust ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 2) Sintering furnace │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Merchant Facility │ ┃ ┃ │ ┃ ┃ 3) Heating Furnace │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 50,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 4) Blast furnace, molten iron furnace, converter, melting/melting furnace or roasting furnace(焙燒 │Dust, sulfur oxides, nitrogen ┃ ┃爐) │Small oxides(Balloon ┃ ┃ - Exhaust gas volume per outlet is 50,000 standard cubic meters per hour │and applicable only to roasting ┃ ┃Facilities exceeding │) ┃ ┃ │ ┃ ┃ 5) Acid treatment facility (continuous type as a facility using hydrochloric acid and hydrogen chloride │Hydrogen Chloride ┃ ┃(Applies only to cases) │ ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 6) Foundry Sand Treatment Facility (Continuous type only) │dust ┃ ┃ - Exhaust gas volume per outlet is 100,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃. When manufacturing fabricated metal products, machinery, equipment, transportation equipment, and furniture │ ┃ ┃Section │ ┃ ┃ 1) Electric furnace (applies only to arc furnaces) │dust ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 2) Heating Furnace │Dust, Nitrogen Oxides, ┃ ┃ - Exhaust gas volume per outlet is 50,000 standard cubic meters per hour │Sulfur Oxides ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 3) Converter, Melting/Fusion Furnace │Dust, sulfur oxides ┃ ┃ - Exhaust gas volume per outlet is 50,000 standard cubic meters per hour │ ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 4) Acid treatment facility (continuous type as a facility using hydrochloric acid and hydrogen chloride │Hydrogen Chloride ┃ ┃(Applies only to cases) │ ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities exceeding │ ┃ ┃ │ ┃ ┃ 5) Foundry Sand Treatment Facility (Continuous type only) │dust ┃ ┃ - Exhaust gas volume per outlet is 100,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 6) Deposition facilities and formulas among semiconductor and other electronic component manufacturing facilities │Hydrogen Chloride ┃ ┃Each facility (for facilities using hydrochloric acid and hydrogen chloride, applicable only to continuous type) │ ┃ ┃) │ ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┠──────────────────────────────┼──────────────┨ ┃Mer. Power generation facilities (excluding hydroelectric and nuclear power generation facilities, and at all emissions │ ┃ ┃Apply to the configuration) │ ┃ ┃ 1) Power Generation Facility │ ┃ ┃ a) Liquid fuel or solid fuel usage facilities │Dust, Nitrogen Oxides, ┃ ┃ - Facilities with an installed capacity of 50 megawatts or more, or │Sulfur Oxides ┃ ┃Facilities with an hourly evaporation rate of 40 tons or more │ ┃ ┃ │ ┃ ┃ b) Gaseous Fuel Usage Facilities │Nitrogen Oxides ┃ ┃ Facilities or cities with an installed capacity of 50 megawatts or more │ ┃ ┃Facilities with an evaporation rate of 40 tons or more per hour │ ┃ ┃ │ ┃ ┃ 2) Internal combustion engine for power generation │ ┃ ┃ a) Liquid or solid fuel usage facilities │Dust, Nitrogen Oxides, ┃ ┃ - Power generation capacity 5,000 kilowatts or more │Sulfur Oxides ┃ ┃ │ ┃ ┃ b) Gaseous Fuel Usage Facilities │Nitrogen Oxides ┃ ┃ - Power generation capacity 5,000 kilowatts or more │ ┃ ┠──────────────────────────────┼──────────────┨ ┃b. Wastewater, waste, and waste gas incineration facilities (including incineration boilers, and m │ ┃ ┃Applies to all emission facilities) │ ┃ ┃ 1) Industrial waste incineration facility (including waste treatment business) │Dust, Nitrogen Oxides, ┃ ┃ - Continuous or semi-continuous with an incineration capacity of 0.4 tons or more per hour │Hydrogen chloride, carbon monoxide ┃ ┃Type Industrial Waste Incineration Facility │Sodium, sulfur oxides ┃ ┃ │ ┃ ┃ 2) Municipal Solid Waste Incineration Facility │Dust, Nitrogen Oxides, ┃ ┃ - Continuous or semi-continuous type with an incineration capacity of 1 ton or more per hour │Hydrogen chloride, carbon monoxide ┃ ┃Municipal Solid Waste Incineration Facility │small ┃ ┃ │ ┃ ┃ 3) Waste Gas Incineration Facility │Nitrogen oxides, monoxide ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │Carbon, sulfur oxides ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 4) Medical Waste Incineration Facility │Dust, Nitrogen Oxides, ┃ ┃ - Continuous or semi-continuous with an incineration capacity of 0.2 tons or more per hour │Hydrogen chloride, carbon monoxide ┃ ┃Medical waste incineration facility () │small ┃ ┃ │ ┃ ┃ 5) Wastewater Incineration Facility │Dust, Nitrogen Oxides, ┃ ┃ - Facilities with an incineration capacity of 0.2 tons or more per hour │Carbon Monoxide ┃ ┠──────────────────────────────┼──────────────┨ ┃. Boiler (Applies to all exhaust facilities) │ ┃ ┃ As a liquid or solid fuel using facility, with an hourly evaporation rate of 40 │Dust, Nitrogen Oxides, ┃ ┃tons or more, or a city with an hourly heat output of 24.76 million kilocalories or more │Sulfur oxides(wood softened ┃ ┃Section │When used as a fuel ┃ ┃ │(Excluding the theory) ┃ ┠──────────────────────────────┼──────────────┨ ┃uh. Solid fuel product usage facility │ ┃ ┃ Solid fuel product usage facilities ("to promote resource conservation and recycling │Dust, Nitrogen Oxides, ┃ ┃refers to facilities prescribed in Article 25-2 of the Act concerning...) │Hydrogen chloride, carbon monoxide ┃ ┃ - The usage of fuel including solid fuel products is 1 ton per hour │small ┃ ┃. However, incineration facilities must be continuous or semi-continuous │ ┃ ┃limits. │ ┃ ┠──────────────────────────────┼──────────────┨ ┃I. Facilities generating particulate matter and gaseous substances and other emission facilities (Mo │ ┃ ┃Applies to all emission facilities) │ ┃ ┃ 1) Desalination and Cleaning Facilities (Continuous type only) │dust ┃ ┃ - Exhaust gas volume per outlet is 40,000 standard cubic meters per hour │ ┃ ┃Facilities above │ ┃ ┃ │ ┃ ┃ 2) Evaporation Facility │dust ┃ ┃ - Exhaust gas volume per outlet is 10,000 standard cubic meters per hour │ ┃ ┃Facilities exceeding │ ┃ ┠──────────────────────────────┼──────────────┨ ┃Department. Heating facilities in other industries │ ┃ ┃ Indirect heating facilities using solid or liquid fuel (raw materials or │Dust, Nitrogen Oxides, ┃ ┃is a product that does not come into direct contact with combustion gases or flames │Sulfur Oxides ┃ ┃(referring to a facility) with a heating capacity of 25 million kilocalories per hour │ ┃ ┃Facilities exceeding │ ┃ ┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━┛ Remarks 1. The capacity of the facility subject to attachment shall be as specified in the emission facility installation permit or installation notification certificate Calculated per discharge outlet based on the capacity of the facility, provided that two or more discharge outlets at the same discharge facility If an outlet is installed, the capacities of the pollution control facilities for each outlet are summed. In this case, The capacity of the pollution control facility shall be applied based on the value converted to standard conditions (0℃, 1 atm). 2. In cases where there are two or more emission outlets subject to attachment at the same workplace, the "Environmental Field Testing· Intermediate data pursuant to the Standard Test Methods for Environmental Pollution under Article 6 of the Act on Inspection, etc. A collector (FEP) must be attached. 3. In the case of incineration facilities, the temperature of the exhaust port and the temperature of the final combustion chamber outlet are respectively... A temperature measuring device must be attached to determine the temperature of the final combustion chamber outlet. However, In the case where a temperature measuring device is attached in accordance with the "Waste Management Act," the temperature measuring device separately It is not necessary to attach. 4. Oxygen meters must be installed in facilities to which standard oxygen concentration applies. 5. The scope of emission facilities subject to attachment is as follows: a. The term “continuous” for deposition, etching, and acid treatment facilities refers to operations that are performed continuously It refers to a facility with a capable structure whose operating time is 8 hours or more per day. B. The term “continuous type” for foundry sand treatment facilities, sand removal facilities, and rust removal facilities refers to continuous operation It refers to a facility with a structure capable of START, where the facility's operating time is 8 hours or more per day. . Among waste gas incineration facilities, incineration facilities that continuously use clean fuel and treatment targets Facilities using gas as a combustion source are excluded from emission facilities subject to attachment. d. Among the evaporation facilities, the vacuum evaporation facility and the facility for recovering and condensing exhaust gas are Excluded from emission facilities subject to attachment. 2. Exemption from Attachment of Automatic Chimney Measuring Devices In the case where an emission facility subject to the installation of automatic chimney measuring devices falls under any of the following subparagraphs, The installation of automatic chimney measuring devices is exempted. a. In cases where the installation of pollution control facilities is exempted pursuant to the proviso of Article 26, Paragraph 1 of the Act (automatic chimney measuring device is exempted) b. Facilities where combustion gases or flames do not come into direct contact with raw materials or products, as per Article 43 (excluding power generation facilities) . In the case of a combustion facility using only liquid fuel that lacks a pollution control facility for removing sulfur oxides (Excluding power generation facilities, attachment is exempted only for sulfur oxide measuring instruments) d. If there is a plan to switch the fuel used for the boiler to clean fuel within 6 months E. In the case of emission facilities with an annual operating period of less than 30 days B. In the case of pollution control facilities with an annual operating period of less than 30 days, the relevant discharge outlet. However, air pollutant emission facilities This applies only to pollution control facilities where the annual operating days are stated as less than 30 days on the installation permit or notification certificate. d. If there is a plan to close the emission facility within 6 months from the date it became subject to attachment Remark: In the event that the grounds for exemption from attachment under each item have ceased to exist, 6 months from the date the grounds for exemption ceased to exist Install an automatic chimney measuring device inside the chimney remote monitoring system control center under Article 19, Paragraph 1, Subparagraph 1, and . 3. Installation Timing and Grace Period for Automatic Chimney Measuring Devices a. Automatic chimney measuring devices that must be attached by the date of the report on the commencement of operation pursuant to Article 30, Paragraph 1 of the Act . However, the number of exhaust outlets at the same business site where a new automatic chimney monitoring device must be installed is 10 If there are more than , all must be attached within 6 months from the start of operation. (a) Notwithstanding subparagraph (a), changing a Class 4 or Class 5 workplace to a Class 1 through Class 3 workplace In cases where one intends to obtain a change permit or file a change notification (hereinafter referred to as "change in the scale of the workplace"), Within 9 months from the date of installation (hereinafter referred to as the "date of change in scale"), an automatic chimney monitoring device must be installed must be. . Notwithstanding Subparagraphs (a) and (b), the emission facilities pursuant to Subparagraph 2 of Annex 8 shall be as follows: chimney automatic Attachment of measuring equipment is deferred. 1) As an existing facility, due to a change in the type and scale of the workplace, the facility newly subject to the installation of automatic chimney measuring equipment has been performed, pollutant emissions were measured at least once a month for one year prior to the date of scale change , pollutants are less than 30 percent of the permissible emission standards (hereinafter referred to as "basic standards") , until pollutants are emitted above the basic charge standard, charging is deferred. In this case, within 6 months from the date of emission exceeding the basic charging standard, Automatic measuring equipment must be attached. 2) New facilities, automatic chimney monitors The attachment of the device is deferred. In this case, for 6 months from the date of emission exceeding the basic charge standard ( If emissions exceed the basic assessment standard within 6 months from the start date, after the start of operations Automatic chimney measuring devices must be installed within one year.