Annex 3 — 계량에 관한 법률 시행령
278291 · 2025-10-01
■ Enforcement Decree of the Act on Weights and Measures [Appendix 3] <Amended Apr. 18, 2023>
of meter manufacturers, meter repair businesses, in-house repairers and meter certification providers
Standards for In-House Facilities and Inspection Equipment (Related to Article 4, Paragraph 3 and Article 5, Paragraph 1)
1. Standards for In-house Facilities and Inspection Equipment of Meter Manufacturers, Meter Repair Businesses, and In-house Repairers
a. On-site facilities
1) Be equipped with facilities suitable for the testing and inspection of measuring instruments
2) The laboratory shall maintain the following environmental conditions
┏━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃RegistrationField │condition ┃
┠─────────────────┼────────────────────────────┨
┃Non-automatic scales, weights and gas meters │Temperature (20 ± 2)oC ┃
┃ │Relative Humidity (30 ~ 70)% ± 10 % ┃
┠─────────────────┼────────────────────────────┨
┃Other meters │Temperature (20 ± 5)oC ┃
┃ │Relative Humidity (30 ~ 70)% ± 10 % ┃
┗━━━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
B. Requirements for Inspection Measuring Instruments
Measuring instruments used for the inspection of a meter must have higher precision and accuracy than the meter itself.
and a calibration certificate that has not exceeded the calibration cycle pursuant to Article 33
.
. Inspection equipment to be provided for each type of meter
┏━━━━━━━┯━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━┯━━━┯━━━┓
┃of the meter's │EquipmentName │Equipment Specifications │Meter│Meter┃
┃Type │ │ │Manufacturing│Repair business┃
┃ │ │ │ja │ja ┃
┃ │ │ │ │ㆍ ┃
┃ │ │ │ │Self-manufacturing┃
┃ │ │ │ │Liza ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃1.Non-automatic │weight │With combination weights from 1 mg to 20 kg │○ │○ ┃
┃scale │ │1-2-2-5 series or 1-1-2-5 series │ │ ┃
┃ │ │s │ │ ┃
┃ │ ├──────────┬──────────┼───┼───┨
┃ │ │Scope of manufacture and repair │200 kg or more of raw material │○ │○ ┃
┃ │ │: Lightweight 200 kg or less │CombinedWeight │ │ ┃
┃ │ │U │ │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │500 kg or more of raw material │○ │○ ┃
┃ │ │: Over 200 kg │CombinedWeight │ │ ┃
┃ │ │Lightweight 500 kg or less │ │ │ ┃
┃ │ │U │ │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │1 000 kg or more │○ │○ ┃
┃ │ │: Over 500 kg 1 t │Combination Weight │ │ ┃
┃ │ │or less │ │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │2 t or more combinations │○ │○ ┃
┃ │ │: greater than 1 t and less than or equal to 2 t │East │ │ ┃
┃ │ │IN case │ │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │5 t or more combinations │○ │○ ┃
┃ │ │: 2 t exceeding 20 t this │East │ │ ┃
┃ │ │In case of │ │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │10 Combinations of t or more │○ │○ ┃
┃ │ │: When exceeding 20 t │weight │ │ ┃
┃ │ │U │ │ │ ┃
┠───────┼────────┼──────────┼──────────┼───┼───┨
┃2. Weight │a. Scale │Scope of Manufacture and Repair │a) Maximum capacity is 2 │○ │○ ┃
┃ │ │: Lightweight 20 kg or less │g or more 200 g US │ │ ┃
┃ │ │U │and minimum eye's │ │ ┃
┃ │ │ │value is 0.005 mg │ │ ┃
┃ │ │ │or less │ │ ┃
┃ │ │ │b) Maximum capacity is 200 │ │ ┃
┃ │ │ │g or more 2 kg US │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │Value 2 mg or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │) Maximum capacity is 2 kg │ │ ┃
┃ │ │ │or more, less than 20 kg │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │value is 50 mg this │ │ ┃
┃ │ │ │The thing that is │ │ ┃
┃ │ │ │) Maximum capacity is 20 │ │ ┃
┃ │ │ │kg or more 500 kg │ │ ┃
┃ │ │ │and minimum eye │ │ ┃
┃ │ │ │is 200 │ │ ┃
┃ │ │ │mg or less │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │a) Maximum capacity is 2 g │○ │○ ┃
┃ │ │: Lightweight 500 kg or less │or more 200 g │ │ ┃
┃ │ │U │and minimum eye's │ │ ┃
┃ │ │ │value is 0.005 mg │ │ ┃
┃ │ │ │The thing that is │ │ ┃
┃ │ │ │b) Maximum capacity is 200 │ │ ┃
┃ │ │ │g or more 2 kg US │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │value of 2 mg or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │) The maximum capacity is 2 │ │ ┃
┃ │ │ │kg or more 20 kg │ │ ┃
┃ │ │ │and minimum eye │ │ ┃
┃ │ │ │is 50 mg │ │ ┃
┃ │ │ │or less │ │ ┃
┃ │ │ │) The maximum capacity is 20 │ │ ┃
┃ │ │ │kg or more 500 │ │ ┃
┃ │ │ │kg and most │ │ ┃
┃ │ │ │The value of the cow's eye │ │ ┃
┃ │ │ │200 mg or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │e) Maximum capacity is 500 │ │ ┃
┃ │ │ │kg or more 1 t US │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │with a value of 20 g or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │a) Maximum capacity is 2 │○ │○ ┃
┃ │ │: If 1 t or less │g or more 200 g │ │ ┃
┃ │ │ │and minimum eye │ │ ┃
┃ │ │ │is 0.005 │ │ ┃
┃ │ │ │mg or less │ │ ┃
┃ │ │ │b) Maximum capacity is 200 │ │ ┃
┃ │ │ │g or more 2 kg US │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │value of 2 mg or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │) Maximum capacity is 2 kg │ │ ┃
┃ │ │ │or more, less than 20 kg │ │ ┃
┃ │ │ │and minimum eye value │ │ ┃
┃ │ │ │with 50 mg or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │) Maximum capacity is 20 │ │ ┃
┃ │ │ │kg or more 500 kg │ │ ┃
┃ │ │ │and minimum │ │ ┃
┃ │ │ │The eye value is 200 │ │ ┃
┃ │ │ │mg or less │ │ ┃
┃ │ │ │e) Maximum capacity is 500 │ │ ┃
┃ │ │ │kg or more 1 t US │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │with a value of 20 g or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │bar) Maximum capacity is 1 t │ │ ┃
┃ │ │ │or more, less than 2 t, │ │ ┃
┃ │ │ │and the minimum eye value │ │ ┃
┃ │ │ │50 g or less │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │Scope of Manufacture and Repair │a) Maximum capacity is 2 g │○ │○ ┃
┃ │ │: If 2 t or less │or more 200 g │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │value is 0.005 mg │ │ ┃
┃ │ │ │The thing that is │ │ ┃
┃ │ │ │b) Maximum capacity is 200 │ │ ┃
┃ │ │ │g or more 2 kg US │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │value of 2 mg or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │) The maximum capacity is 2 │ │ ┃
┃ │ │ │kg or more 20 kg │ │ ┃
┃ │ │ │and minimum eye │ │ ┃
┃ │ │ │is 50 mg │ │ ┃
┃ │ │ │or less │ │ ┃
┃ │ │ │) Maximum capacity is 20 │ │ ┃
┃ │ │ │kg or more 500 kg │ │ ┃
┃ │ │ │and minimum eye │ │ ┃
┃ │ │ │is 200 mg │ │ ┃
┃ │ │ │or less │ │ ┃
┃ │ │ │e) Maximum capacity is 500 │ │ ┃
┃ │ │ │kg or more 1 t US │ │ ┃
┃ │ │ │and minimum eye's │ │ ┃
┃ │ │ │with a value of 20 g or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │bar) Maximum capacity is 1 t │ │ ┃
┃ │ │ │or more, less than 2 t, │ │ ┃
┃ │ │ │and minimum eye value │ │ ┃
┃ │ │ │with 50 g or less │ │ ┃
┃ │ │ │thing │ │ ┃
┃ │ │ │Company) Maximum capacity is 2 │ │ ┃
┃ │ │ │t or greater and minimum │ │ ┃
┃ │ │ │The value of the eye is 100 │ │ ┃
┃ │ │ │g less than or equal to │ │ ┃
┃ │ ├──────────┼──────────┼───┼───┨
┃ │ │In other cases │corresponding to that range │○ │○ ┃
┃ │ │ │shall be equipped with a scale │ │ ┃
┃ ├────────┼──────────┴──────────┼───┼───┨
┃ │B. Weights │1 mg up to 20 kg 1-2-2-5 also │○ │○ ┃
┃ │ │is a 1-1-2-5 type combination weight │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Other weights │and above the maximum capacity to be manufactured and repaired │○ │○ ┃
┃ │ │Combination Weight │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃3. Gas Meter │a. Error Inspection │1) By compensating for product-specific temperature and pressure │○ │○ ┃
┃ │device │From minimum flow rate to maximum flow rate │ │ ┃
┃ │ │Things available for testing │ │ ┃
┃ │ │2) The inlet temperature of the test air is the average ambient │ │ ┃
┃ │ │and the │ │ ┃
┃ │ │Relative humidity that does not cause axis │ │ ┃
┃ │ │Will be able to maintain │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │B. Leakage Test │1) Internal and external leakage of the test device are │○ │○ ┃
┃ │START │Will be smaller than the larger of the negative values │ │ ┃
┃ │ │ a) The maximum │ │ ┃
┃ │ │0.1 % of the amount owned │ │ ┃
┃ │ │ b) 100 cm3/h │ │ ┃
┃ │ │2) Max gas meter to be manufactured and repaired │ │ ┃
┃ │ │Pressurization of more than twice the operating pressure (Pmax) │ │ ┃
┃ │ │It is possible to confirm the leakage of the test meter, and │ │ ┃
┃ │ │It will be possible │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. In case of pressure loss │1) Pressure difference between the inlet and outlet of the gas meter │○ │○ ┃
┃ │experience │capable of measurement │ │ ┃
┃ │ │2) The pressure outlet is perpendicular to the pipe axis │ │ ┃
┃ │ │It must be, and the diameter must be 3 mm or more and │ │ ┃
┃ │ │Will not protrude into the pipe │ │ ┃
┃ │ │3) Gas meter pressure change as average value │ │ ┃
┃ │ │and │ │ ┃
┃ │ │Pressure measurement will be possible │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Thermometer │The outlet temperature of the gas meter is 0.1 °C or less │○ │○ ┃
┃ │ │로 측정이 가능할 것 │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │E. Error Inspection │Minimum flow rate (Qmin) and maximum flow rate (Qmax) │○ │○ ┃
┃ │Meter for START │, │ │ ┃
┃ │ │capable of error measurement │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │B. Constant Temperature and Humidity Unit │1) Temperature: (-20 ~ 60)oC ± 5 oC 이 │○ │ ┃
┃ │ │Tomorrow's Thing │ │ ┃
┃ │ │2) Relative Humidity: (30 ~ 96)% ± 10 % │ │ ┃
┃ │ │It must be within │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │Company. Thermometer/Humidifier │Temperature (0 ~ 50)oC, Relative Humidity (30 ~ │○ │○ ┃
┃ │Rokgye │96)% will be possible │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃4. Water Meter │a. Error Inspection │1) Volume Measurement Range │○ │○ ┃
┃5. Hot Water Meter │device │ a) Nominal bore 50 mm or less: Maximum allowable │ │ ┃
┃ │ │and 0.2 % │ │ ┃
┃ │ │or less │ │ ┃
┃ │ │ b) Nominal bore exceeding 50 mm 100 │ │ ┃
┃ │ │mm or less: Maximum flow rate is 160 m3/h │ │ ┃
┃ │ │or greater, and measurement error of 0.2% or less │ │ ┃
┃ │ │possible │ │ ┃
┃ │ │ ) Nominal bore exceeding 100 mm 200 │ │ ┃
┃ │ │mm or less: Maximum flow rate is 400 m3/h │ │ ┃
┃ │ │or greater, and measurement error of 0.2% or less │ │ ┃
┃ │ │possible │ │ ┃
┃ │ │ d) Nominal bore exceeding 200 mm 350 │ │ ┃
┃ │ │mm or less: Maximum flow rate is 630 m3/h │ │ ┃
┃ │ │or greater, and measurement error of 0.2% or less │ │ ┃
┃ │ │possible │ │ ┃
┃ │ │2) The change in water temperature during the test is 5 │ │ ┃
┃ │ │oC be within │ │ ┃
┃ │ │3) Constant pressure tank capable of maintaining a constant pressure │ │ ┃
┃ │ │, etc. │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │or. In case of pressure loss │1) Pressure measurement points at the inlet and outlet and straight pipe section │○ │○ ┃
┃ │experience │meets the requirements of the water meter technical standards │ │ ┃
┃ │ │Will be satisfied │ │ ┃
┃ │ │2) The average pressure loss measuring device of the meter is │ │ ┃
┃ │ │Must be able to measure at least 0.1 MPa │ │ ┃
┃ │ │and the resolution shall be 0.01 MPa or less │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Pressure tester │Maximum allowance for water meters to be manufactured or repaired │○ │○ ┃
┃ │(Omission of Item A │At a pressure equivalent to twice the START pressure for 1 minute │ │ ┃
┃ │VehicleInspectionDevice │Can be maintained for a period of time and the leakage amount during the test END │ │ ┃
┃ │Equipment specifications for START │Measurement will be possible │ │ ┃
┃ │을 충족하는 │ │ │ ┃
┃ │Internal pressure test machine │ │ │ ┃
┃ │with │ │ │ ┃
┃ │, my │ │ │ ┃
┃ │pressure tester │ │ │ ┃
┃ │Separately equipped │ │ │ ┃
┃ │cannot │ │ │ ┃
┃ │) │ │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. At durability │1) Nominal bore 50 mm or less: Maximum barrel │○ │ ┃
┃ │Experimental device(회 │Overflow 20 m3/h or more │ │ ┃
┃ │All parts │2) Nominal bore exceeding 50 mm: Max │ │ ┃
┃ │The capital city that has │Passing flow rate 100 m3/h or more │ │ ┃
┃ │meter or │3) Measurement of temperature and pressure of fluid in piping │ │ ┃
┃ │On the hot water meter │It will be possible │ │ ┃
┃ │Limits) │ │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃6. Oil Meter │a. Volume Measurement │Volume measurement range │○ │○ ┃
┃ │device ( │ 1) Nominal bore 50 mm or less: Maximum barrel │ │ ┃
┃ │Error Inspection Station │Excess flow rate is 20 m3/h or more, and 0.1 % │ │ ┃
┃ │Equipment specifications │or less │ │ ┃
┃ │meets the requirements │ 2) Nominal bore exceeding 50 mm and 80 mm │ │ ┃
┃ │is volume measurement │or less: Maximum throughflow 40 m3/h or more │ │ ┃
┃ │MTQ10f065e7f790ccea01535 with START function │and error measurement of 0.1% or less │ │ ┃
┃ │, part │Possible things │ │ ┃
┃ │MeasuringDevice │ 3) Nominal bore exceeding 80 mm 100 │ │ ┃
┃ │separately │mm or less: Maximum throughflow 80 m3/h │ │ ┃
┃ │will not be equipped │or greater, and measurement error of 0.1% or less │ │ ┃
┃ │can) │possible │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │B. Error Inspection │1) Constant pressure tank capable of maintaining a constant pressure │○ │○ ┃
┃ │device │Equipped with │ │ ┃
┃ │ │2) The temperature of the test fluid and tank is 0.1 oC │ │ ┃
┃ │ │Be able to measure down to │ │ ┃
┃ │ │3) Oil meter according to type approval standards │ │ ┃
┃ │ │It will be possible to measure the vehicle │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. For durability, │Endure for 100 hours at the following flow rate │○ │ ┃
┃ │experience │capable of performance testing │ │ ┃
┃ │ (rotating part │ 1) Nominal bore 50 mm or less: Maximum barrel │ │ ┃
┃ │possessing oil │Overflow 20 m3/h or more │ │ ┃
┃ │Limited to │ 2) Nominal bore exceeding 50 mm and 80 mm │ │ ┃
┃ │) │or less: Maximum throughflow 40 m3/h or more │ │ ┃
┃ │ │ 3) Nominal bore exceeding 80 mm 100 │ │ ┃
┃ │ │mm or less: Maximum throughflow 80 m3/h │ │ ┃
┃ │ │or more │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Pressure Tester │Can pressurize to 1.96 MPa or higher │○ │○ ┃
┃ │(Namogui O │and can maintain a pressurized state for more than 5 minutes │ │ ┃
┃ │Vehicle Inspection Device │will be │ │ ┃
┃ │Equipment specifications in START │2) To check for pressurization and oil leakage │ │ ┃
┃ │을 충족하는 │can be │ │ ┃
┃ │Internal pressure test machine │ │ │ ┃
┃ │with │ │ │ ┃
┃ │, my │ │ │ ┃
┃ │pressure tester │ │ │ ┃
┃ │Separately equipped │ │ │ ┃
┃ │cannot │ │ │ ┃
┃ │) │ │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃7. Fuel dispenser │a. Error Inspection │1) Inspection tank: capacity of 20 L or more and │○ │○ ┃
┃8. AdBlue Meter │device │with a minimum eye value of 10 mL or less │ │ ┃
┃ │ │2) Inspection tank: Capacity 100 L or more │ │ ┃
┃ │ │and with a minimum eye value of 50 mL or less │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │B. Gas Remover │injected as specified in the type approval criteria │○ │ ┃
┃ │Tester(Fueling │It will be possible to measure the amount of air │ │ ┃
┃ │and │ │ │ ┃
┃ │and, of subparagraph (a) │ │ │ ┃
┃ │Error Inspection Station │ │ │ ┃
┃ │Equipment specifications │ │ │ ┃
┃ │meets the requirements │ │ │ ┃
┃ │is gas removal │ │ │ ┃
┃ │Test Machine │ │ │ ┃
┃ │with │ │ │ ┃
┃ │, │ │ │ ┃
┃ │Stain Remover Time │ │ │ ┃
┃ │Test report separate │ │ │ ┃
┃ │not equipped │ │ │ ┃
┃ │cannot be │ │ │ ┃
┃ │) │ │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Hose volume │Fuel gun required by the fuel dispenser technical standards │○ │ ┃
┃ │Change Tester │Supply device, pressurizing device, pressure gauge, volume change │ │ ┃
┃ │ │A quantity reading device, etc. is provided │ │ ┃
┃ │ │thing │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃9. LPG Meter │a. Scale │The maximum capacity is 30 kg or more, and the minimum eye's │○ │○ ┃
┃ │ │Value 10 g or less │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │B. Density-based liquid system │The scale range is (0.500 ~ 0.650) │○ │○ ┃
┃ │ │up to g/cm3, the minimum eye value │ │ ┃
┃ │ │0.001 g/cm3 or less │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. For density measurement │LPG │○ │○ ┃
┃ │Cylinder │ │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Thermometer │The measurement range is (0 to 30)°C or higher. │○ │○ ┃
┃ │ │with a cow eye value of 0.1 °C or less │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃10. Nunsaegim │a. Inspection tank │The capacity is 10 L or 20 L or less, and the minimum │○ │○ ┃
┃Tank │ │with an eye value of 10 mL or less │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │B. Impact Tester │Pressurize air of 35 kPa or higher into the tank │○ │ ┃
┃ │ │When free-falling from a height of 2 m or more │ │ ┃
┃ │ │Will be able to kill │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Pressure tester │Can pressurize to 0.196 MPa or higher │○ │ ┃
┃ │ │and can maintain a pressurized state for more than 5 minutes │ │ ┃
┃ │ │can be possible │ │ ┃
┃ │ │2) To check for pressurization and oil leakage │ │ ┃
┃ │ │can be │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃11. Accumulated │a. Flow Rate Error │1) Volume Measurement Range │○ │○ ┃
┃Calorimeter │Inspection Device │ a) Nominal bore 50 mm or less: Maximum barrel │ │ ┃
┃ │ │The excess flow rate is 20 m3/h or more, and 0.2 │ │ ┃
┃ │ │% or less │ │ ┃
┃ │ │ b) Nominal bore exceeding 50 mm 100 │ │ ┃
┃ │ │mm or less: Maximum through flow 160 │ │ ┃
┃ │ │m3/h, and an error of 0.2% or less │ │ ┃
┃ │ │Those capable of being settled │ │ ┃
┃ │ │ ) Nominal bore exceeding 100 mm 200 │ │ ┃
┃ │ │mm or less: Maximum through flow 400 │ │ ┃
┃ │ │m3/h, and an error of 0.2% or less │ │ ┃
┃ │ │Those capable of being settled │ │ ┃
┃ │ │ d) Nominal bore exceeding 200 mm 350 │ │ ┃
┃ │ │mm or less: Maximum through flow 630 │ │ ┃
┃ │ │m3/h, and an error of 0.2% or less │ │ ┃
┃ │ │Those capable of being settled │ │ ┃
┃ │ │2) A thermometer at the pipe inlet of the inspection device │ │ ┃
┃ │ │is attached, and │ │ ┃
┃ │ │shall be equipped with a pressure gauge │ │ ┃
┃ │ │3) The change in water temperature during the test is 5 │ │ ┃
┃ │ │oC be within │ │ ┃
┃ │ │4) Constant pressure tank capable of maintaining a constant pressure │ │ ┃
┃ │ │Equipped with │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │B. Flow Signal │to generate a flow rate signal identical to the flow rate section │○ │○ ┃
┃ │Generator │, and │ │ ┃
┃ │ │shall be equipped with an input pulse counter function │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │. Constant temperature bath │The temperature range is (0–150)°C or higher, and the temperature │○ │○ ┃
┃ │ │Degree adjustment is 0.1 °C or less, 4 │ │ ┃
┃ │ │Hold for longer than │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │d. Pressure tester │Those with a maximum pressure of 1.96 MPa or higher │○ │○ ┃
┃ │(Item A's Use │ │ │ ┃
┃ │Quantity Error Inspection │ │ │ ┃
┃ │device equipment │ │ │ ┃
┃ │specifications │ │ │ ┃
┃ │internal pressure │ │ │ ┃
┃ │Test function │ │ │ ┃
┃ │exists │ │ │ ┃
┃ │is the pressure test │ │ │ ┃
┃ │device separately │ │ │ ┃
┃ │will not be equipped │ │ │ ┃
┃ │can) │ │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │E. Thermometer │measurement range is (0–150)°C or higher, and the │○ │○ ┃
┃ │ │The value of the cow's eye is 0.01 °C or less. │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │bar. Durability │1) Nominal bore 50 mm or less: Maximum barrel │○ │ ┃
┃ │experience │The flow rate is 20 m3/h or more, and the test oil │ │ ┃
┃ │ (rotating part is │When the body temperature cycles at 90 °C ± 5 °C │ │ ┃
┃ │with accumulated heat │Will be able to kill │ │ ┃
┃ │Limited to meters │2) Nominal bore exceeding 50 mm: Max │ │ ┃
┃ │) │The throughflow rate must be 50 m3/h or more. │ │ ┃
┃ │ │3) Temperature measurement of the fluid passing through at the inlet │ │ ┃
┃ │ │It will be possible │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │Company. Constant Temperature and Humidity Chamber │1) Temperature: (-20 ~ 60)oC ± 5 oC 이 │○ │ ┃
┃ │ │Tomorrow's Thing │ │ ┃
┃ │ │2) Relative Humidity: (30 ~ 95)% ± 10 % │ │ ┃
┃ │ │It will be within │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │Ah. In case of pressure loss │1) Pressure measurement points at the inlet and outlet and directly │○ │○ ┃
┃ │experience │Gwanbu conforms to technical standards for cumulative heat meters │ │ ┃
┃ │ │Things to do │ │ ┃
┃ │ │2) The measurement of average pressure loss is up to 0.1 MPa │ │ ┃
┃ │ │It can do so, and the resolution is 0.01 MPa │ │ ┃
┃ │ │be less than or equal to │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃12. Power │a. Reference Power │1) AC Electricity Meter: Single Phase(single │○ │○ ┃
┃Weight meter │Weight meter │phase) or three phases │ │ ┃
┃ │ │Accuracy within 0.1% at power factor 1.0 │ │ ┃
┃ │ │shall be, standards for products manufactured or repaired │ │ ┃
┃ │ │Voltage and maximum current, phase (0 ~ │ │ ┃
┃ │ │360)°, frequency (45 ~ 65)Hz │ │ ┃
┃ │ │can determine │ │ ┃
┃ │ │2) DC power meter: Accuracy is 0.1% │ │ ┃
┃ │ │Tomorrow's item, the product's │ │ ┃
┃ │ │Can measure baseline voltage and maximum current │ │ ┃
┃ │ │will be │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │or. Hub load foot │1) AC power meter: Manufacturing or repairing │○ │○ ┃
┃ │Production( Test │Reference voltage and maximum current of the product, phase │ │ ┃
┃ │Power supply │(0 ~ 360)°, Frequency (45 ~ 65)Hz │ │ ┃
┃ │_Class_Device) │is single-phase or │ │ ┃
┃ │ │It can occur in three phases │ │ ┃
┃ │ │을 것 │ │ ┃
┃ │ │2) DC power meter: Manufacturers/repairers │ │ ┃
┃ │ │product │ │ ┃
┃ │ │will be able to generate DC power │ │ ┃
┠───────┼────────┼─────────────────────┼───┼───┨
┃13. Electric │a. Reference Power │1) AC Charger: Single Phase │○ │○ ┃
┃Automobile │Weight meter │or before charging to three phase │ │ ┃
┃Charger │ │Power measurement accuracy at power factor 1.0 │ │ ┃
┃ │ │within 0.1%, manufacturing or repairing │ │ ┃
┃ │ │product, above │ │ ┃
┃ │ │Phase (0 ~ 360)°, Frequency (45 ~ │ │ ┃
┃ │ │65)Hz will be able to measure │ │ ┃
┃ │ │2) DC Charger: Charging Power Measurement │ │ ┃
┃ │ │The accuracy shall be within 0.1%, manufacturing/processing │ │ ┃
┃ │ │The standard voltage and maximum voltage of the product │ │ ┃
┃ │ │capable of measuring types │ │ ┃
┃ ├────────┼─────────────────────┼───┼───┨
┃ │or. Hubbuha Bal │1) AC Charger: Products manufactured or repaired │○ │○ ┃
┃ │Production( Test │(0 │ │ ┃
┃ │Power supply for │~ 360)°, Frequency (45 ~ 65)Hz Total │ │ ┃
┃ │_Supply_Device) │power single-phase or three-phase │ │ ┃
┃ │ │(three phases) may occur │ │ ┃
┃ │ │thing │ │ ┃
┃ │ │2) DC Charger: Products manufactured or repaired │ │ ┃
┃ │ │Corresponding to the reference voltage and maximum current of │ │ ┃
┃ │ │will be able to generate DC power │ │ ┃
┠───────┴────────┴─────────────────────┴───┴───┨
┃Remarks ┃
┃ 1. In cases where two or more types of meters are manufactured or repaired at the same workplace, the above table ┃
┃, duplicate inspection facilities shall not be provided redundantly ┃
┃cannot. ┃
┃ 2. Pressure loss tester of Subparagraph 3(c), pressure loss test of Subparagraphs 4, 5(b) and 5(c) ┃
┃machines and pressure testers, the pressure tester under subparagraph (d) of Item 6, and the (a) under Items 7, 8 (b), and (c) ┃
┃Spore remover tester and hose volume change tester, impact test of subparagraphs (b) and (c) of subparagraph 10 ┃
┃The apparatus and pressure tester, the pressure tester and pressure loss tester of subparagraphs (d) and (h) of subparagraph 11 ┃
┃In cases where the right to use has been secured through a lease agreement or a contract regarding joint use, that... ┃
┃During the contract period, the relevant facilities are deemed to be equipped. ┃
┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
2. Standards for Self-Facilities and Equipment of Weighing Certification Providers
a. On-site facilities: Equipped with facilities suitable for metering certification
B. Facilities: Equipped with a meter used for metering certification.