Annex 3 — 계량에 관한 법률 시행령

278291 · 2025-10-01

■ Enforcement Decree of the Act on Weights and Measures [Appendix 3] <Amended Apr. 18, 2023> of meter manufacturers, meter repair businesses, in-house repairers and meter certification providers Standards for In-House Facilities and Inspection Equipment (Related to Article 4, Paragraph 3 and Article 5, Paragraph 1) 1. Standards for In-house Facilities and Inspection Equipment of Meter Manufacturers, Meter Repair Businesses, and In-house Repairers a. On-site facilities 1) Be equipped with facilities suitable for the testing and inspection of measuring instruments 2) The laboratory shall maintain the following environmental conditions ┏━━━━━━━━━━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃RegistrationField │condition ┃ ┠─────────────────┼────────────────────────────┨ ┃Non-automatic scales, weights and gas meters │Temperature (20 ± 2)oC ┃ ┃ │Relative Humidity (30 ~ 70)% ± 10 % ┃ ┠─────────────────┼────────────────────────────┨ ┃Other meters │Temperature (20 ± 5)oC ┃ ┃ │Relative Humidity (30 ~ 70)% ± 10 % ┃ ┗━━━━━━━━━━━━━━━━━┷━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛ B. Requirements for Inspection Measuring Instruments Measuring instruments used for the inspection of a meter must have higher precision and accuracy than the meter itself. and a calibration certificate that has not exceeded the calibration cycle pursuant to Article 33 . . Inspection equipment to be provided for each type of meter ┏━━━━━━━┯━━━━━━━━┯━━━━━━━━━━━━━━━━━━━━━┯━━━┯━━━┓ ┃of the meter's │EquipmentName │Equipment Specifications │Meter│Meter┃ ┃Type │ │ │Manufacturing│Repair business┃ ┃ │ │ │ja │ja ┃ ┃ │ │ │ │ㆍ ┃ ┃ │ │ │ │Self-manufacturing┃ ┃ │ │ │ │Liza ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃1.Non-automatic │weight │With combination weights from 1 mg to 20 kg │○ │○ ┃ ┃scale │ │1-2-2-5 series or 1-1-2-5 series │ │ ┃ ┃ │ │s │ │ ┃ ┃ │ ├──────────┬──────────┼───┼───┨ ┃ │ │Scope of manufacture and repair │200 kg or more of raw material │○ │○ ┃ ┃ │ │: Lightweight 200 kg or less │CombinedWeight │ │ ┃ ┃ │ │U │ │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │500 kg or more of raw material │○ │○ ┃ ┃ │ │: Over 200 kg │CombinedWeight │ │ ┃ ┃ │ │Lightweight 500 kg or less │ │ │ ┃ ┃ │ │U │ │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │1 000 kg or more │○ │○ ┃ ┃ │ │: Over 500 kg 1 t │Combination Weight │ │ ┃ ┃ │ │or less │ │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │2 t or more combinations │○ │○ ┃ ┃ │ │: greater than 1 t and less than or equal to 2 t │East │ │ ┃ ┃ │ │IN case │ │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │5 t or more combinations │○ │○ ┃ ┃ │ │: 2 t exceeding 20 t this │East │ │ ┃ ┃ │ │In case of │ │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │10 Combinations of t or more │○ │○ ┃ ┃ │ │: When exceeding 20 t │weight │ │ ┃ ┃ │ │U │ │ │ ┃ ┠───────┼────────┼──────────┼──────────┼───┼───┨ ┃2. Weight │a. Scale │Scope of Manufacture and Repair │a) Maximum capacity is 2 │○ │○ ┃ ┃ │ │: Lightweight 20 kg or less │g or more 200 g US │ │ ┃ ┃ │ │U │and minimum eye's │ │ ┃ ┃ │ │ │value is 0.005 mg │ │ ┃ ┃ │ │ │or less │ │ ┃ ┃ │ │ │b) Maximum capacity is 200 │ │ ┃ ┃ │ │ │g or more 2 kg US │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │Value 2 mg or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │) Maximum capacity is 2 kg │ │ ┃ ┃ │ │ │or more, less than 20 kg │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │value is 50 mg this │ │ ┃ ┃ │ │ │The thing that is │ │ ┃ ┃ │ │ │) Maximum capacity is 20 │ │ ┃ ┃ │ │ │kg or more 500 kg │ │ ┃ ┃ │ │ │and minimum eye │ │ ┃ ┃ │ │ │is 200 │ │ ┃ ┃ │ │ │mg or less │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │a) Maximum capacity is 2 g │○ │○ ┃ ┃ │ │: Lightweight 500 kg or less │or more 200 g │ │ ┃ ┃ │ │U │and minimum eye's │ │ ┃ ┃ │ │ │value is 0.005 mg │ │ ┃ ┃ │ │ │The thing that is │ │ ┃ ┃ │ │ │b) Maximum capacity is 200 │ │ ┃ ┃ │ │ │g or more 2 kg US │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │value of 2 mg or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │) The maximum capacity is 2 │ │ ┃ ┃ │ │ │kg or more 20 kg │ │ ┃ ┃ │ │ │and minimum eye │ │ ┃ ┃ │ │ │is 50 mg │ │ ┃ ┃ │ │ │or less │ │ ┃ ┃ │ │ │) The maximum capacity is 20 │ │ ┃ ┃ │ │ │kg or more 500 │ │ ┃ ┃ │ │ │kg and most │ │ ┃ ┃ │ │ │The value of the cow's eye │ │ ┃ ┃ │ │ │200 mg or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │e) Maximum capacity is 500 │ │ ┃ ┃ │ │ │kg or more 1 t US │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │with a value of 20 g or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │a) Maximum capacity is 2 │○ │○ ┃ ┃ │ │: If 1 t or less │g or more 200 g │ │ ┃ ┃ │ │ │and minimum eye │ │ ┃ ┃ │ │ │is 0.005 │ │ ┃ ┃ │ │ │mg or less │ │ ┃ ┃ │ │ │b) Maximum capacity is 200 │ │ ┃ ┃ │ │ │g or more 2 kg US │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │value of 2 mg or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │) Maximum capacity is 2 kg │ │ ┃ ┃ │ │ │or more, less than 20 kg │ │ ┃ ┃ │ │ │and minimum eye value │ │ ┃ ┃ │ │ │with 50 mg or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │) Maximum capacity is 20 │ │ ┃ ┃ │ │ │kg or more 500 kg │ │ ┃ ┃ │ │ │and minimum │ │ ┃ ┃ │ │ │The eye value is 200 │ │ ┃ ┃ │ │ │mg or less │ │ ┃ ┃ │ │ │e) Maximum capacity is 500 │ │ ┃ ┃ │ │ │kg or more 1 t US │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │with a value of 20 g or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │bar) Maximum capacity is 1 t │ │ ┃ ┃ │ │ │or more, less than 2 t, │ │ ┃ ┃ │ │ │and the minimum eye value │ │ ┃ ┃ │ │ │50 g or less │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │Scope of Manufacture and Repair │a) Maximum capacity is 2 g │○ │○ ┃ ┃ │ │: If 2 t or less │or more 200 g │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │value is 0.005 mg │ │ ┃ ┃ │ │ │The thing that is │ │ ┃ ┃ │ │ │b) Maximum capacity is 200 │ │ ┃ ┃ │ │ │g or more 2 kg US │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │value of 2 mg or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │) The maximum capacity is 2 │ │ ┃ ┃ │ │ │kg or more 20 kg │ │ ┃ ┃ │ │ │and minimum eye │ │ ┃ ┃ │ │ │is 50 mg │ │ ┃ ┃ │ │ │or less │ │ ┃ ┃ │ │ │) Maximum capacity is 20 │ │ ┃ ┃ │ │ │kg or more 500 kg │ │ ┃ ┃ │ │ │and minimum eye │ │ ┃ ┃ │ │ │is 200 mg │ │ ┃ ┃ │ │ │or less │ │ ┃ ┃ │ │ │e) Maximum capacity is 500 │ │ ┃ ┃ │ │ │kg or more 1 t US │ │ ┃ ┃ │ │ │and minimum eye's │ │ ┃ ┃ │ │ │with a value of 20 g or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │bar) Maximum capacity is 1 t │ │ ┃ ┃ │ │ │or more, less than 2 t, │ │ ┃ ┃ │ │ │and minimum eye value │ │ ┃ ┃ │ │ │with 50 g or less │ │ ┃ ┃ │ │ │thing │ │ ┃ ┃ │ │ │Company) Maximum capacity is 2 │ │ ┃ ┃ │ │ │t or greater and minimum │ │ ┃ ┃ │ │ │The value of the eye is 100 │ │ ┃ ┃ │ │ │g less than or equal to │ │ ┃ ┃ │ ├──────────┼──────────┼───┼───┨ ┃ │ │In other cases │corresponding to that range │○ │○ ┃ ┃ │ │ │shall be equipped with a scale │ │ ┃ ┃ ├────────┼──────────┴──────────┼───┼───┨ ┃ │B. Weights │1 mg up to 20 kg 1-2-2-5 also │○ │○ ┃ ┃ │ │is a 1-1-2-5 type combination weight │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Other weights │and above the maximum capacity to be manufactured and repaired │○ │○ ┃ ┃ │ │Combination Weight │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃3. Gas Meter │a. Error Inspection │1) By compensating for product-specific temperature and pressure │○ │○ ┃ ┃ │device │From minimum flow rate to maximum flow rate │ │ ┃ ┃ │ │Things available for testing │ │ ┃ ┃ │ │2) The inlet temperature of the test air is the average ambient │ │ ┃ ┃ │ │and the │ │ ┃ ┃ │ │Relative humidity that does not cause axis │ │ ┃ ┃ │ │Will be able to maintain │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │B. Leakage Test │1) Internal and external leakage of the test device are │○ │○ ┃ ┃ │START │Will be smaller than the larger of the negative values ​​ │ │ ┃ ┃ │ │ a) The maximum │ │ ┃ ┃ │ │0.1 % of the amount owned │ │ ┃ ┃ │ │ b) 100 cm3/h │ │ ┃ ┃ │ │2) Max gas meter to be manufactured and repaired │ │ ┃ ┃ │ │Pressurization of more than twice the operating pressure (Pmax) │ │ ┃ ┃ │ │It is possible to confirm the leakage of the test meter, and │ │ ┃ ┃ │ │It will be possible │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. In case of pressure loss │1) Pressure difference between the inlet and outlet of the gas meter │○ │○ ┃ ┃ │experience │capable of measurement │ │ ┃ ┃ │ │2) The pressure outlet is perpendicular to the pipe axis │ │ ┃ ┃ │ │It must be, and the diameter must be 3 mm or more and │ │ ┃ ┃ │ │Will not protrude into the pipe │ │ ┃ ┃ │ │3) Gas meter pressure change as average value │ │ ┃ ┃ │ │and │ │ ┃ ┃ │ │Pressure measurement will be possible │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Thermometer │The outlet temperature of the gas meter is 0.1 °C or less │○ │○ ┃ ┃ │ │로 측정이 가능할 것 │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │E. Error Inspection │Minimum flow rate (Qmin) and maximum flow rate (Qmax) │○ │○ ┃ ┃ │Meter for START │, │ │ ┃ ┃ │ │capable of error measurement │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │B. Constant Temperature and Humidity Unit │1) Temperature: (-20 ~ 60)oC ± 5 oC 이 │○ │ ┃ ┃ │ │Tomorrow's Thing │ │ ┃ ┃ │ │2) Relative Humidity: (30 ~ 96)% ± 10 % │ │ ┃ ┃ │ │It must be within │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │Company. Thermometer/Humidifier │Temperature (0 ~ 50)oC, Relative Humidity (30 ~ │○ │○ ┃ ┃ │Rokgye │96)% will be possible │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃4. Water Meter │a. Error Inspection │1) Volume Measurement Range │○ │○ ┃ ┃5. Hot Water Meter │device │ a) Nominal bore 50 mm or less: Maximum allowable │ │ ┃ ┃ │ │and 0.2 % │ │ ┃ ┃ │ │or less │ │ ┃ ┃ │ │ b) Nominal bore exceeding 50 mm 100 │ │ ┃ ┃ │ │mm or less: Maximum flow rate is 160 m3/h │ │ ┃ ┃ │ │or greater, and measurement error of 0.2% or less │ │ ┃ ┃ │ │possible │ │ ┃ ┃ │ │ ) Nominal bore exceeding 100 mm 200 │ │ ┃ ┃ │ │mm or less: Maximum flow rate is 400 m3/h │ │ ┃ ┃ │ │or greater, and measurement error of 0.2% or less │ │ ┃ ┃ │ │possible │ │ ┃ ┃ │ │ d) Nominal bore exceeding 200 mm 350 │ │ ┃ ┃ │ │mm or less: Maximum flow rate is 630 m3/h │ │ ┃ ┃ │ │or greater, and measurement error of 0.2% or less │ │ ┃ ┃ │ │possible │ │ ┃ ┃ │ │2) The change in water temperature during the test is 5 │ │ ┃ ┃ │ │oC be within │ │ ┃ ┃ │ │3) Constant pressure tank capable of maintaining a constant pressure │ │ ┃ ┃ │ │, etc. │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │or. In case of pressure loss │1) Pressure measurement points at the inlet and outlet and straight pipe section │○ │○ ┃ ┃ │experience │meets the requirements of the water meter technical standards │ │ ┃ ┃ │ │Will be satisfied │ │ ┃ ┃ │ │2) The average pressure loss measuring device of the meter is │ │ ┃ ┃ │ │Must be able to measure at least 0.1 MPa │ │ ┃ ┃ │ │and the resolution shall be 0.01 MPa or less │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Pressure tester │Maximum allowance for water meters to be manufactured or repaired │○ │○ ┃ ┃ │(Omission of Item A │At a pressure equivalent to twice the START pressure for 1 minute │ │ ┃ ┃ │VehicleInspectionDevice │Can be maintained for a period of time and the leakage amount during the test END │ │ ┃ ┃ │Equipment specifications for START │Measurement will be possible │ │ ┃ ┃ │을 충족하는 │ │ │ ┃ ┃ │Internal pressure test machine │ │ │ ┃ ┃ │with │ │ │ ┃ ┃ │, my │ │ │ ┃ ┃ │pressure tester │ │ │ ┃ ┃ │Separately equipped │ │ │ ┃ ┃ │cannot │ │ │ ┃ ┃ │) │ │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. At durability │1) Nominal bore 50 mm or less: Maximum barrel │○ │ ┃ ┃ │Experimental device(회 │Overflow 20 m3/h or more │ │ ┃ ┃ │All parts │2) Nominal bore exceeding 50 mm: Max │ │ ┃ ┃ │The capital city that has │Passing flow rate 100 m3/h or more │ │ ┃ ┃ │meter or │3) Measurement of temperature and pressure of fluid in piping │ │ ┃ ┃ │On the hot water meter │It will be possible │ │ ┃ ┃ │Limits) │ │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃6. Oil Meter │a. Volume Measurement │Volume measurement range │○ │○ ┃ ┃ │device ( │ 1) Nominal bore 50 mm or less: Maximum barrel │ │ ┃ ┃ │Error Inspection Station │Excess flow rate is 20 m3/h or more, and 0.1 % │ │ ┃ ┃ │Equipment specifications │or less │ │ ┃ ┃ │meets the requirements │ 2) Nominal bore exceeding 50 mm and 80 mm │ │ ┃ ┃ │is volume measurement │or less: Maximum throughflow 40 m3/h or more │ │ ┃ ┃ │MTQ10f065e7f790ccea01535 with START function │and error measurement of 0.1% or less │ │ ┃ ┃ │, part │Possible things │ │ ┃ ┃ │MeasuringDevice │ 3) Nominal bore exceeding 80 mm 100 │ │ ┃ ┃ │separately │mm or less: Maximum throughflow 80 m3/h │ │ ┃ ┃ │will not be equipped │or greater, and measurement error of 0.1% or less │ │ ┃ ┃ │can) │possible │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │B. Error Inspection │1) Constant pressure tank capable of maintaining a constant pressure │○ │○ ┃ ┃ │device │Equipped with │ │ ┃ ┃ │ │2) The temperature of the test fluid and tank is 0.1 oC │ │ ┃ ┃ │ │Be able to measure down to │ │ ┃ ┃ │ │3) Oil meter according to type approval standards │ │ ┃ ┃ │ │It will be possible to measure the vehicle │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. For durability, │Endure for 100 hours at the following flow rate │○ │ ┃ ┃ │experience │capable of performance testing │ │ ┃ ┃ │ (rotating part │ 1) Nominal bore 50 mm or less: Maximum barrel │ │ ┃ ┃ │possessing oil │Overflow 20 m3/h or more │ │ ┃ ┃ │Limited to │ 2) Nominal bore exceeding 50 mm and 80 mm │ │ ┃ ┃ │) │or less: Maximum throughflow 40 m3/h or more │ │ ┃ ┃ │ │ 3) Nominal bore exceeding 80 mm 100 │ │ ┃ ┃ │ │mm or less: Maximum throughflow 80 m3/h │ │ ┃ ┃ │ │or more │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Pressure Tester │Can pressurize to 1.96 MPa or higher │○ │○ ┃ ┃ │(Namogui O │and can maintain a pressurized state for more than 5 minutes │ │ ┃ ┃ │Vehicle Inspection Device │will be │ │ ┃ ┃ │Equipment specifications in START │2) To check for pressurization and oil leakage │ │ ┃ ┃ │을 충족하는 │can be │ │ ┃ ┃ │Internal pressure test machine │ │ │ ┃ ┃ │with │ │ │ ┃ ┃ │, my │ │ │ ┃ ┃ │pressure tester │ │ │ ┃ ┃ │Separately equipped │ │ │ ┃ ┃ │cannot │ │ │ ┃ ┃ │) │ │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃7. Fuel dispenser │a. Error Inspection │1) Inspection tank: capacity of 20 L or more and │○ │○ ┃ ┃8. AdBlue Meter │device │with a minimum eye value of 10 mL or less │ │ ┃ ┃ │ │2) Inspection tank: Capacity 100 L or more │ │ ┃ ┃ │ │and with a minimum eye value of 50 mL or less │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │B. Gas Remover │injected as specified in the type approval criteria │○ │ ┃ ┃ │Tester(Fueling │It will be possible to measure the amount of air │ │ ┃ ┃ │and │ │ │ ┃ ┃ │and, of subparagraph (a) │ │ │ ┃ ┃ │Error Inspection Station │ │ │ ┃ ┃ │Equipment specifications │ │ │ ┃ ┃ │meets the requirements │ │ │ ┃ ┃ │is gas removal │ │ │ ┃ ┃ │Test Machine │ │ │ ┃ ┃ │with │ │ │ ┃ ┃ │, │ │ │ ┃ ┃ │Stain Remover Time │ │ │ ┃ ┃ │Test report separate │ │ │ ┃ ┃ │not equipped │ │ │ ┃ ┃ │cannot be │ │ │ ┃ ┃ │) │ │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Hose volume │Fuel gun required by the fuel dispenser technical standards │○ │ ┃ ┃ │Change Tester │Supply device, pressurizing device, pressure gauge, volume change │ │ ┃ ┃ │ │A quantity reading device, etc. is provided │ │ ┃ ┃ │ │thing │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃9. LPG Meter │a. Scale │The maximum capacity is 30 kg or more, and the minimum eye's │○ │○ ┃ ┃ │ │Value 10 g or less │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │B. Density-based liquid system │The scale range is (0.500 ~ 0.650) │○ │○ ┃ ┃ │ │up to g/cm3, the minimum eye value │ │ ┃ ┃ │ │0.001 g/cm3 or less │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. For density measurement │LPG │○ │○ ┃ ┃ │Cylinder │ │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Thermometer │The measurement range is (0 to 30)°C or higher. │○ │○ ┃ ┃ │ │with a cow eye value of 0.1 °C or less │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃10. Nunsaegim │a. Inspection tank │The capacity is 10 L or 20 L or less, and the minimum │○ │○ ┃ ┃Tank │ │with an eye value of 10 mL or less │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │B. Impact Tester │Pressurize air of 35 kPa or higher into the tank │○ │ ┃ ┃ │ │When free-falling from a height of 2 m or more │ │ ┃ ┃ │ │Will be able to kill │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Pressure tester │Can pressurize to 0.196 MPa or higher │○ │ ┃ ┃ │ │and can maintain a pressurized state for more than 5 minutes │ │ ┃ ┃ │ │can be possible │ │ ┃ ┃ │ │2) To check for pressurization and oil leakage │ │ ┃ ┃ │ │can be │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃11. Accumulated │a. Flow Rate Error │1) Volume Measurement Range │○ │○ ┃ ┃Calorimeter │Inspection Device │ a) Nominal bore 50 mm or less: Maximum barrel │ │ ┃ ┃ │ │The excess flow rate is 20 m3/h or more, and 0.2 │ │ ┃ ┃ │ │% or less │ │ ┃ ┃ │ │ b) Nominal bore exceeding 50 mm 100 │ │ ┃ ┃ │ │mm or less: Maximum through flow 160 │ │ ┃ ┃ │ │m3/h, and an error of 0.2% or less │ │ ┃ ┃ │ │Those capable of being settled │ │ ┃ ┃ │ │ ) Nominal bore exceeding 100 mm 200 │ │ ┃ ┃ │ │mm or less: Maximum through flow 400 │ │ ┃ ┃ │ │m3/h, and an error of 0.2% or less │ │ ┃ ┃ │ │Those capable of being settled │ │ ┃ ┃ │ │ d) Nominal bore exceeding 200 mm 350 │ │ ┃ ┃ │ │mm or less: Maximum through flow 630 │ │ ┃ ┃ │ │m3/h, and an error of 0.2% or less │ │ ┃ ┃ │ │Those capable of being settled │ │ ┃ ┃ │ │2) A thermometer at the pipe inlet of the inspection device │ │ ┃ ┃ │ │is attached, and │ │ ┃ ┃ │ │shall be equipped with a pressure gauge │ │ ┃ ┃ │ │3) The change in water temperature during the test is 5 │ │ ┃ ┃ │ │oC be within │ │ ┃ ┃ │ │4) Constant pressure tank capable of maintaining a constant pressure │ │ ┃ ┃ │ │Equipped with │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │B. Flow Signal │to generate a flow rate signal identical to the flow rate section │○ │○ ┃ ┃ │Generator │, and │ │ ┃ ┃ │ │shall be equipped with an input pulse counter function │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │. Constant temperature bath │The temperature range is (0–150)°C or higher, and the temperature │○ │○ ┃ ┃ │ │Degree adjustment is 0.1 °C or less, 4 │ │ ┃ ┃ │ │Hold for longer than │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │d. Pressure tester │Those with a maximum pressure of 1.96 MPa or higher │○ │○ ┃ ┃ │(Item A's Use │ │ │ ┃ ┃ │Quantity Error Inspection │ │ │ ┃ ┃ │device equipment │ │ │ ┃ ┃ │specifications │ │ │ ┃ ┃ │internal pressure │ │ │ ┃ ┃ │Test function │ │ │ ┃ ┃ │exists │ │ │ ┃ ┃ │is the pressure test │ │ │ ┃ ┃ │device separately │ │ │ ┃ ┃ │will not be equipped │ │ │ ┃ ┃ │can) │ │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │E. Thermometer │measurement range is (0–150)°C or higher, and the │○ │○ ┃ ┃ │ │The value of the cow's eye is 0.01 °C or less. │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │bar. Durability │1) Nominal bore 50 mm or less: Maximum barrel │○ │ ┃ ┃ │experience │The flow rate is 20 m3/h or more, and the test oil │ │ ┃ ┃ │ (rotating part is │When the body temperature cycles at 90 °C ± 5 °C │ │ ┃ ┃ │with accumulated heat │Will be able to kill │ │ ┃ ┃ │Limited to meters │2) Nominal bore exceeding 50 mm: Max │ │ ┃ ┃ │) │The throughflow rate must be 50 m3/h or more. │ │ ┃ ┃ │ │3) Temperature measurement of the fluid passing through at the inlet │ │ ┃ ┃ │ │It will be possible │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │Company. Constant Temperature and Humidity Chamber │1) Temperature: (-20 ~ 60)oC ± 5 oC 이 │○ │ ┃ ┃ │ │Tomorrow's Thing │ │ ┃ ┃ │ │2) Relative Humidity: (30 ~ 95)% ± 10 % │ │ ┃ ┃ │ │It will be within │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │Ah. In case of pressure loss │1) Pressure measurement points at the inlet and outlet and directly │○ │○ ┃ ┃ │experience │Gwanbu conforms to technical standards for cumulative heat meters │ │ ┃ ┃ │ │Things to do │ │ ┃ ┃ │ │2) The measurement of average pressure loss is up to 0.1 MPa │ │ ┃ ┃ │ │It can do so, and the resolution is 0.01 MPa │ │ ┃ ┃ │ │be less than or equal to │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃12. Power │a. Reference Power │1) AC Electricity Meter: Single Phase(single │○ │○ ┃ ┃Weight meter │Weight meter │phase) or three phases │ │ ┃ ┃ │ │Accuracy within 0.1% at power factor 1.0 │ │ ┃ ┃ │ │shall be, standards for products manufactured or repaired │ │ ┃ ┃ │ │Voltage and maximum current, phase (0 ~ │ │ ┃ ┃ │ │360)°, frequency (45 ~ 65)Hz │ │ ┃ ┃ │ │can determine │ │ ┃ ┃ │ │2) DC power meter: Accuracy is 0.1% │ │ ┃ ┃ │ │Tomorrow's item, the product's │ │ ┃ ┃ │ │Can measure baseline voltage and maximum current │ │ ┃ ┃ │ │will be │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │or. Hub load foot │1) AC power meter: Manufacturing or repairing │○ │○ ┃ ┃ │Production( Test │Reference voltage and maximum current of the product, phase │ │ ┃ ┃ │Power supply │(0 ~ 360)°, Frequency (45 ~ 65)Hz │ │ ┃ ┃ │_Class_Device) │is single-phase or │ │ ┃ ┃ │ │It can occur in three phases │ │ ┃ ┃ │ │을 것 │ │ ┃ ┃ │ │2) DC power meter: Manufacturers/repairers │ │ ┃ ┃ │ │product │ │ ┃ ┃ │ │will be able to generate DC power │ │ ┃ ┠───────┼────────┼─────────────────────┼───┼───┨ ┃13. Electric │a. Reference Power │1) AC Charger: Single Phase │○ │○ ┃ ┃Automobile │Weight meter │or before charging to three phase │ │ ┃ ┃Charger │ │Power measurement accuracy at power factor 1.0 │ │ ┃ ┃ │ │within 0.1%, manufacturing or repairing │ │ ┃ ┃ │ │product, above │ │ ┃ ┃ │ │Phase (0 ~ 360)°, Frequency (45 ~ │ │ ┃ ┃ │ │65)Hz will be able to measure │ │ ┃ ┃ │ │2) DC Charger: Charging Power Measurement │ │ ┃ ┃ │ │The accuracy shall be within 0.1%, manufacturing/processing │ │ ┃ ┃ │ │The standard voltage and maximum voltage of the product │ │ ┃ ┃ │ │capable of measuring types │ │ ┃ ┃ ├────────┼─────────────────────┼───┼───┨ ┃ │or. Hubbuha Bal │1) AC Charger: Products manufactured or repaired │○ │○ ┃ ┃ │Production( Test │(0 │ │ ┃ ┃ │Power supply for │~ 360)°, Frequency (45 ~ 65)Hz Total │ │ ┃ ┃ │_Supply_Device) │power single-phase or three-phase │ │ ┃ ┃ │ │(three phases) may occur │ │ ┃ ┃ │ │thing │ │ ┃ ┃ │ │2) DC Charger: Products manufactured or repaired │ │ ┃ ┃ │ │Corresponding to the reference voltage and maximum current of │ │ ┃ ┃ │ │will be able to generate DC power │ │ ┃ ┠───────┴────────┴─────────────────────┴───┴───┨ ┃Remarks ┃ ┃ 1. In cases where two or more types of meters are manufactured or repaired at the same workplace, the above table ┃ ┃, duplicate inspection facilities shall not be provided redundantly ┃ ┃cannot. ┃ ┃ 2. Pressure loss tester of Subparagraph 3(c), pressure loss test of Subparagraphs 4, 5(b) and 5(c) ┃ ┃machines and pressure testers, the pressure tester under subparagraph (d) of Item 6, and the (a) under Items 7, 8 (b), and (c) ┃ ┃Spore remover tester and hose volume change tester, impact test of subparagraphs (b) and (c) of subparagraph 10 ┃ ┃The apparatus and pressure tester, the pressure tester and pressure loss tester of subparagraphs (d) and (h) of subparagraph 11 ┃ ┃In cases where the right to use has been secured through a lease agreement or a contract regarding joint use, that... ┃ ┃During the contract period, the relevant facilities are deemed to be equipped. ┃ ┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛ 2. Standards for Self-Facilities and Equipment of Weighing Certification Providers a. On-site facilities: Equipped with facilities suitable for metering certification B. Facilities: Equipped with a meter used for metering certification.