Annex 10 — 건설기술 진흥법 시행령
286847 · 2026-06-09
■ Enforcement Decree of the Construction Technology Promotion Act [Appendix 10] <Amended Jan. 5, 2021>
Certification Standards by Grade for Steel Structure Plants (Related to Article 96, Paragraph 4)
1. Types of Certification Audit Items
┌────────┬──────────────────────────────┐
│Key Assessment Items │Detailed Assessment Items │
├────────┼──────────────────────────────┤
│A. Factory Overview │1) Factory Site Area │
│ │2) Product processing workshop area │
│ │3) Pre-assembly site area │
│ │4) Annual Processing Performance │
├────────┼──────────────────────────────┤
│B. Technical Personnel │Construction technical personnel according to the standards notified by the Minister of Land, Infrastructure and Transport │
├────────┼──────────────────────────────┤
│. Manufacturing and testing facilities│1) Manufacturing Equipment │
│ │2) Welding Equipment │
│ │3) Crane │
│ │4) Test and Inspection Equipment │
├────────┼──────────────────────────────┤
│d. Quality Control Status│1) General Management │
│ │2) Manufacturing Technology │
│ │3) Production Status and Quality Control │
│ │4) Working Environment │
└────────┴──────────────────────────────┘
Remarks
1. Product processing workshop: A building with a roof and two or more exterior walls
2. Pre-assembly site: Before assembling the finished product at the construction site, steel structures at the steel structure factory
A place to assemble components and inspect for defects
3. Crane: Overhead traveling crane inside a factory
2. Minimum standards for basic assessment items
┌───┬───────────┬─────────┬─────────────┐
│Grade │Product Processing Workshop Area │Assembly Area (㎡) │Crane (ton) │
│ │(㎡) │ │ │
│ ├───┬───────┼───┬─────┼──┬──────────┤
│ │Bridge │Architecture │Bridge │Architecture │Bridge│Architecture │
├───┼───┼───────┼───┼─────┼──┼──────────┤
│1Grade │5,000 │4,000 │2,000 │- │50 │50 │
├───┼───┼───────┼───┼─────┼──┼──────────┤
│2Grade │4,000 │3,000 │1,500 │- │50 │30 │
├───┼───┼───────┼───┼─────┼──┼──────────┤
│3rd grade │2,000 │1,000 │ 700 │- │15 │8 │
├───┼───┼───────┼───┼─────┼──┼──────────┤
│4Grade │ 500 │ 400 │- │- │8 │- │
└───┴───┴───────┴───┴─────┴──┴──────────┘
3. Criteria for Manufacturing Capability by Factory Certification Grade
┌──┬────────────────────────────────────┐
│Grade│Production Capability │
│ ├───────────┬────────────────────────┤
│ │Bridge Sector │Architecture Sector │
├──┼───────────┼────────────────────────┤
│1Grade │All bridges │All Buildings │
├──┼───────────┼────────────────────────┤
│2Grade │A. General Bridge │a. Plate thickness (t) of the main member used in welding operations: │
│ │B. Between piers │t≤50mm │
│ │Maximum distance is 100 meters │b. Major structures of buildings with fewer than 26 stories (including basement floors) │
│ │미만인 특수교량 │Grandfather │
├──┼───────────┼────────────────────────┤
│3rd grade │The best between piers │a. Plate thickness (t) of the main member used in welding operations │
│ │Distance 50 meters or less │ - SS400 Grade Steel: t≤30mm │
│ │pedestrian overpass (special │ - SM490 Grade Steel: t≤25mm │
│ │Excluding overpasses) │b. Major [unclear] of buildings with fewer than 16 stories (including basement floors) │
│ │ │Structural Section (Maximum span 30m or less) │
├──┼───────────┼────────────────────────┤
│4Grade │The closest between piers │a. Plate thickness (t) of the main member used in welding operations: │
│ │Distance is 30 meters or less │t≤16mm │
│ │pedestrian overpass (special │B. Eaves height 20m or less (maximum span 30m or less) │
│ │Excluding overpasses) │ │
└──┴───────────┴────────────────────────┘
Remarks
1. "Special bridge" refers to a suspension bridge (a bridge that supports the deck with main cables and auxiliary cables
. The same applies hereinafter) bridges such as cable-stayed bridges, arch bridges, and truss bridges, and the space between piers
It refers to a curved bridge with a maximum distance of 50 meters or more.
2. "General bridge" refers to a bridge that does not fall under the category of a special bridge.
3. "Special overpass" refers to pedestrian overpasses exclusively for sidewalks, such as suspension bridges, cable-stayed bridges, arch bridges, and truss bridges
says.
4. A factory that has received factory certification shall manufacture steel structures below the production capability standards of the relevant grade
can.