Form 1 — 지하안전관리에 관한 특별법 시행규칙
264555 · 2024-07-30
■ Enforcement Rules of the Special Act on Underground Safety Management [Attachment Form No. 1] <Newly Inserted Oct. 31, 2023>
Safety Management Plan · Safety Management Regulations Verification Checklist
Inspection Overview
a. Inspection Target:
b. Purpose of Inspection:
2. Inspection Result
┌─────────┬───────────────────────────┬─────┬─────┐
│Classification │Inspection Items │Inspection Results │Results of Measures Taken │
├─────────┼───────────────────────────┼─────┼─────┤
│A. Safety Management Plan │1) Regarding Ground Safety Review │ │ │
│Compliance Status ├───────────────────────────┼─────┼─────┤
│(Construction Business Operator, │ a) Have temporary earth-retaining structures, such as walls, support members, wales and intermediate piles, │ │ │
│Registered Housing Construction Business Operator │been installed in accordance with the design drawings? │ │ │
│Target) ├───────────────────────────┼─────┼─────┤
│ │ 2) Regarding Measurement Plan │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ a) Installation quantity, location, frequency, timing, etc. per measuring instrument │ │ │
│ │Is the measurement management standard being complied with? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ b) Have the monitoring results ever exceeded the monitoring management criteria │ │ │
│ │? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ b-1) (If the monitoring criteria were exceeded) Were the countermeasures specified in the safety management plan │ │ │
│ │implemented? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ 3) Reinforcement of areas vulnerable to ground subsidence and water cutoff measures (where │ │ │
│ │water cutoff grouting is used) │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ a) Was a test application of water cutoff grouting carried out? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ b) Was the water cutoff method implemented in accordance with the design drawings? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ c) Has the permeability coefficient established by the test application been │ │ │
│ │achieved? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ 4) Regarding Blasted Rock Excavation Methods (When Excavating Blasted Rock) │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ a) Was a test blast conducted to assess the effects of blasting on the area surrounding the construction site │ │ │
│ │? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ b) Are permissible vibration and noise limits being observed during rock blasting │ │ │
│ │? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ 5) Regarding internal and external drainage facilities at construction sites │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ a) Are drainage facilities inside and outside the construction site regularly │ │ │
│ │inspected? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ b) Is daily sediment runoff monitored? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ c) Is there any groundwater seepage at the construction site, including from walls and floors │ │ │
│ │? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ c-1) (If groundwater seepage occurs) Have measures under the construction site's groundwater and soil runoff │ │ │
│ │management plan been implemented? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ d) Are drainage channels inside and outside the site inspected and maintained, and is drainage provided during │ │ │
│ │rainfall (via manholes, settling basins, pumps, etc.) │ │ │
│ │? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ 6) Verification of Area Surrounding Excavation │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ a) Have CCTV inspections and subsurface geophysical surveys of underground utilities in the area affected by the project │ │ │
│ │been conducted in accordance with the safety management plan │ │ │
│ │before construction and upon its completion, etc.? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ b) After CCTV inspections and subsurface geophysical surveys, have measures under the safety management plan │ │ │
│ │been implemented? │ │ │
├─────────┼───────────────────────────┼─────┼─────┤
│B. Safety Management Regulations │ 1) Have there been changes in the name, location, scale, use or managing entity of the underground facility │ │ │
│Compliance Status │? │ │ │
│(Applicable to Underground Facility Managers) ├───────────────────────────┼─────┼─────┤
│(Applicable) │ 2) Are management personnel responsible for safety inspection and verification of underground facilities │ │ │
│ │organized and deployed in accordance with the organizational chart │ │ │
│ │? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ 3) Compliance with Safety Inspection Items │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ a) Do you possess existing inspection data? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ b) Have you identified previously occurring defects? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ c) Was a visual inspection for ground subsidence performed (at least once a year)? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ d) Was a ground-penetrating radar survey for cavities conducted │ │ │
│ │(at least once every five years)? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ e) If cavities were previously identified, were repair or reinforcement measures │ │ │
│ │taken? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ 4) Are underground facilities and surrounding ground being managed in accordance with measures for ensuring safety and │ │ │
│ │maintenance? │ │ │
│ ├───────────────────────────┼─────┼─────┤
│ │ 5) Are operations conducted according to the emergency response and restoration plan for situations such as ground subsidence │ │ │
│ │? │ │ │
└─────────┴───────────────────────────┴─────┴─────┘
Inspection Date and Time: Year month day
Inspector: (Department) (Rank) (Name) (Signature or seal)