Form 6 — 인공조명에 의한 빛공해 방지법 시행규칙
278975 · 2025-10-01
■ Enforcement Rules of the Act on the Prevention of Light Pollution Caused by Artificial Lighting [Attachment Form No. 6] <Newly Inserted May 26, 2020>
Light Pollution Inspection Results Report
(front)
───────────────────┬────────────────────────
IssuanceNumber │MeasurementDate
│
───────────────────┴────────────────────────
─────┬──────────────────────────────────────
Applicant │Name
├──────────────────────────────────────
│Address
─────┴──────────────────────────────────────
─────┬──────────────────────────────────────
Target │InstallationLocation
Lighting Fixture├────────────┬─────────────────────────
│Type of Lighting Environment Management Zone │Land-Use District
├────────────┼─────────────────────────
│Type of Lighting Fixture │Light Distribution Classification
├────────────┼─────────────────────────
│Lighting Method │Type of Light Source
─────┴────────────┴─────────────────────────
─────┬────────────┬─────────────────────────
Measuring Instrument│Name of Illuminance Meter │Model No. of Illuminance Meter
├────────────┼─────────────────────────
│Name of Luminance Meter │Model No. of Luminance Meter
─────┴────────────┴─────────────────────────
─────┬────────┬──────┬──────────────────────
Measure │MeasurementTime │Measurement Distance │Person Taking Measurements
Data ├──────┬─┴─┬───┬┴──┬───────────────────
│Measurement Results │Measured Value│Background Value│Target Value│Evaluation Value
├──────┼───┼───┼───┼───────────────────
│Illuminance(lx) │ │ │ │
├──────┼───┼───┼───┼───────────────────
│Luminance(cd/m2) │ │ │ │
─────┴──────┴───┴───┴───┴───────────────────
─────┬───────┬───┬────┬─────────────────────
FinalValue │Evaluated Illuminance │ │Evaluated Luminance│
│ │lx │ │cd/m2
─────┴───────┴───┴────┴─────────────────────
Pursuant to Article 16-2(3) of the Act on the Prevention of Light Pollution Caused by Artificial Lighting and Article 13(2) of its Enforcement Rule,
the light pollution inspection results are hereby notified.
Year month day
┏━━━━┓
Light Pollution Inspection Agency ┃Official Seal of the Head ┃
┗━━━━┛
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
──────┬─────────────────────────────────────
Attached Documents │ One copy of inspection-result analysis data (raw data sheet)
──────┴─────────────────────────────────────
210mm×297mm[White Paper(80g/㎡)]
(rear)
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Instructions for Completion
────────────────────────────────────────────────────
1. For 'Land-Use District', enter the use district specified in Article 36 of the National Land Planning and Utilization Act.
2. For 'Type of Lighting Fixture', enter 'streetlight', 'security light', 'park light', 'electronic advertising sign', 'general advertising lighting',
'decorative lighting', etc.
3. For 'Light Distribution Classification', enter 'full cut-off', 'cut-off', 'semi-cut-off' or
'non-cut-off', etc., depending on the distribution of light emitted by the fixture.
4. For 'Lighting Method', enter 'internally illuminated', 'channel-letter', 'externally illuminated', 'self-luminous', and whether it flashes, etc.
5. For 'Type of Light Source', enter 'high-pressure sodium lamp', 'metal-halide lamp', 'fluorescent lamp', 'halogen lamp', 'LED',
etc.
6. "Measurement Distance" is the distance from the lighting fixture under measurement to the measurement point.
7. For the "measured value" of illuminance, enter the illuminance measured using the measurement method specified in the Standard Test Methods for Light Pollution.
8. The 'Background Value' of illuminance is the illuminance measured at the relevant position without the target lighting fixture.
9. For 'Target Value' of illuminance, subtract the background value from the measured value.
10. For 'Evaluated Value' of illuminance, multiply the target value by the illuminance correction factor (0.9).
11. For the "measured value" of luminance, enter the luminance measured using the measurement method specified in the Standard Test Methods for Light Pollution.
12. For 'Evaluated Value' of luminance, multiply the measured value by the luminance correction factor (0.9).
13. Round the calculated measurement values for each entry in the report to the following decimal places:
┌──────┬────┬──────┐
│Item │Unit │Decimal Places │
├──────┼────┼──────┤
│a. Illuminance │(lx) │First │
│b. Luminance │(cd/m2) │First │
└──────┴────┴──────┘
────────────────────────────────────────────────────
210mm×297mm[White Paper(80g/㎡)]