Form 1 — 지진ㆍ화산재해대책법 시행규칙
233141 · 2021-06-10
■ Enforcement Rules of the Earthquake and Volcanic Disaster Countermeasures Act [Attachment Form No. 1-2] <Newly Inserted June 4, 2020>
(Front)
┏━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃ ┃
┃ Performance Inspection Report Number: 0000-000 ┃
┃ ┃
┃Performance Inspection Report for Seismic Acceleration Sensors ┃
┃ 1. Applicant ┃
┃ Company Name: ┃
┃ Ad- dress: ┃
┃ 2. Inspection Product ┃
┃ Manufacturer: ┃
┃ Model Name: ┃
┃ Device Number: ┃
┃ Number of directions: ┃
┃ 3. Inspection Standards: Article 2-2, Paragraph 1 and Annex 1 of the Enforcement Rules of the Earthquake and Volcanic Disaster Countermeasures Act ┃
┃ 4. Inspection Results: Refer to Attachment "Inspection Results" ┃
┃ 5. Purpose of Test Report: Performance Inspection ┃
┃ 6. Receipt Date: Year month day ┃
┃ 7. Issue Date: Year month day ┃
┃ ┃
┃ Inspector Approver ┃
┃ ┃
┃ ┃
┃ ┃
┃ (Signature) (Signature) ┃
┃ ───── ───── ┃
┃ ┃
┃ ┃
┃ ○○○ Team Hong Gil-dong ○○○ Team Yi Sun-sin ┃
┃ ┃
┃ Pursuant to Article 2-2(3) of the Enforcement Rule of the Earthquake and Volcanic Disaster Countermeasures Act, this performance ┃
┃ inspection report for seismic acceleration sensors is hereby issued. ┃
┃ ┃
┃ ┏━━━━┓ ┃
┃ Performance Inspection Agency┃Official seal of the head of the agency ┃ ┃
┃ ┗━━━━┛ ┃
┃ ┃
┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛
210mm×297mm[White Paper (150g/㎡)]
(rear)
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
Performance Inspection Report No.: 0000-000
──────────────────────────────────────────────────────────
Performance Inspection Agency : Inspection Number: No. ○○-○○-○○
──────────┬─────────────────────────────┬─────┬───────────
Requesting Organization (Company) │Inspection period │Inspection location │Overall assessment
──────────┼─────────────────────────────┼─────┼───────────
│ │ │
──────────┴─────────────────────────────┴─────┴───────────
─────┬──────┬─────────────────────────────────────────────
Reference Equipment│Model │
├──────┼─────────────────────────────────────────────
│Serial Number(S/N)│
─────┴──────┴─────────────────────────────────────────────
─────┬──────┬───────────────────────────┬────┬────────────
Equipment inspected│Manufacturer (country)│Date of manufacture (year and month) │Model Name │Serial Number(S/N)
Equipment ├──────┼───────────────────────────┼────┼────────────
│ │ │ │
─────┴──────┴───────────────────────────┴────┴────────────
────┬────┬──────────────────────────────┬────┬────┬───────
Category │Item │Detailed item │Measurement results│Compliance│Remarks
────┼────┼──────────────────────────────┼────┼────┼───────
Seismic │Measurement components│· 3-directional component (1 vertical direction, 2 horizontal directions) │ │ │
Acceleration│ │• Two-direction components (for facilities) │ │ │
Detector│ │• One-direction component (for facilities) │ │ │
├────┼──────────────────────────────┼────┼────┼───────
│Frequency │ㆍ 0.1~50Hz range │ │ │
│Area │· Error range < 3dB │ │ │
├────┼──────────────────────────────┼────┼────┼───────
│Dynamic range│· Noise level: 120dB or higher (100 samples/sec) │ │ │
│ │ (When the maximum measurement range is 2g, the RMS noise value is 0.002gal or less)│ │ │
├────┼──────────────────────────────┼────┼────┼───────
│Output Voltage│· Output voltage linearity with respect to acceleration within 1% │ │ │
│Linearity │· DC tilting test error < 1% │ │ │
├────┼──────────────────────────────┼────┼────┼───────
│Inter-component │• Within 1% (for free-field use) │ │ │
│sensitivity error│ㆍ Within 2% (for facilities) │ │ │
├────┼──────────────────────────────┼────┼────┼───────
│Output voltage│• Within the maximum input voltage of the seismic acceleration recorder │ │ │
├────┼──────────────────────────────┼────┼────┼───────
│OutputMethod│· Differential Output Method (Differential) Status │ │ │
────┴────┴──────────────────────────────┴────┴────┴───────
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
──────────────────────────────────────────────────────────
210mm×297mm[White Paper (150g/㎡)]