Form 1 — 지진ㆍ화산재해대책법 시행규칙

233141 · 2021-06-10

■ Enforcement Rules of the Earthquake and Volcanic Disaster Countermeasures Act [Attachment Form No. 1-2] <Newly Inserted June 4, 2020> (Front) ┏━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓ ┃ ┃ ┃ Performance Inspection Report Number: 0000-000 ┃ ┃ ┃ ┃Performance Inspection Report for Seismic Acceleration Sensors ┃ ┃ 1. Applicant ┃ ┃ Company Name: ┃ ┃ Ad- dress: ┃ ┃ 2. Inspection Product ┃ ┃ Manufacturer: ┃ ┃ Model Name: ┃ ┃ Device Number: ┃ ┃ Number of directions: ┃ ┃ 3. Inspection Standards: Article 2-2, Paragraph 1 and Annex 1 of the Enforcement Rules of the Earthquake and Volcanic Disaster Countermeasures Act ┃ ┃ 4. Inspection Results: Refer to Attachment "Inspection Results" ┃ ┃ 5. Purpose of Test Report: Performance Inspection ┃ ┃ 6. Receipt Date: Year month day ┃ ┃ 7. Issue Date: Year month day ┃ ┃ ┃ ┃ Inspector Approver ┃ ┃ ┃ ┃ ┃ ┃ ┃ ┃ (Signature) (Signature) ┃ ┃ ───── ───── ┃ ┃ ┃ ┃ ┃ ┃ ○○○ Team Hong Gil-dong ○○○ Team Yi Sun-sin ┃ ┃ ┃ ┃ Pursuant to Article 2-2(3) of the Enforcement Rule of the Earthquake and Volcanic Disaster Countermeasures Act, this performance ┃ ┃ inspection report for seismic acceleration sensors is hereby issued. ┃ ┃ ┃ ┃ ┏━━━━┓ ┃ ┃ Performance Inspection Agency┃Official seal of the head of the agency ┃ ┃ ┃ ┗━━━━┛ ┃ ┃ ┃ ┗━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┛ 210mm×297mm[White Paper (150g/㎡)] (rear) ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━ Performance Inspection Report No.: 0000-000 ────────────────────────────────────────────────────────── Performance Inspection Agency : Inspection Number: No. ○○-○○-○○ ──────────┬─────────────────────────────┬─────┬─────────── Requesting Organization (Company) │Inspection period │Inspection location │Overall assessment ──────────┼─────────────────────────────┼─────┼─────────── │ │ │ ──────────┴─────────────────────────────┴─────┴─────────── ─────┬──────┬───────────────────────────────────────────── Reference Equipment│Model │ ├──────┼───────────────────────────────────────────── │Serial Number(S/N)│ ─────┴──────┴───────────────────────────────────────────── ─────┬──────┬───────────────────────────┬────┬──────────── Equipment inspected│Manufacturer (country)│Date of manufacture (year and month) │Model Name │Serial Number(S/N) Equipment ├──────┼───────────────────────────┼────┼──────────── │ │ │ │ ─────┴──────┴───────────────────────────┴────┴──────────── ────┬────┬──────────────────────────────┬────┬────┬─────── Category │Item │Detailed item │Measurement results│Compliance│Remarks ────┼────┼──────────────────────────────┼────┼────┼─────── Seismic │Measurement components│· 3-directional component (1 vertical direction, 2 horizontal directions) │ │ │ Acceleration│ │• Two-direction components (for facilities) │ │ │ Detector│ │• One-direction component (for facilities) │ │ │ ├────┼──────────────────────────────┼────┼────┼─────── │Frequency │ㆍ 0.1~50Hz range │ │ │ │Area │· Error range < 3dB │ │ │ ├────┼──────────────────────────────┼────┼────┼─────── │Dynamic range│· Noise level: 120dB or higher (100 samples/sec) │ │ │ │ │ (When the maximum measurement range is 2g, the RMS noise value is 0.002gal or less)│ │ │ ├────┼──────────────────────────────┼────┼────┼─────── │Output Voltage│· Output voltage linearity with respect to acceleration within 1% │ │ │ │Linearity │· DC tilting test error < 1% │ │ │ ├────┼──────────────────────────────┼────┼────┼─────── │Inter-component │• Within 1% (for free-field use) │ │ │ │sensitivity error│ㆍ Within 2% (for facilities) │ │ │ ├────┼──────────────────────────────┼────┼────┼─────── │Output voltage│• Within the maximum input voltage of the seismic acceleration recorder │ │ │ ├────┼──────────────────────────────┼────┼────┼─────── │OutputMethod│· Differential Output Method (Differential) Status │ │ │ ────┴────┴──────────────────────────────┴────┴────┴─────── ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━ ────────────────────────────────────────────────────────── 210mm×297mm[White Paper (150g/㎡)]